Combined use of color duplex ultrasonography and B-flow imaging for evaluation of patients with carotid artery stenosis

被引:0
|
作者
Tola, M [1 ]
Yurdakul, M [1 ]
Cumhur, T [1 ]
机构
[1] Turkiye Yuksek Ihtisas Hosp, Dept Radiol, TR-06100 Ankara, Turkey
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Color duplex ultrasonography (CDU) is a standard method of noninvasive evaluation of internal carotid artery stenosis (ICAS). B-flow imaging (BFI), on the other hand, is a newer method. We investigated the accuracy of the two noninvasive tests-CDU and BFI-each separately and as a combination of the two tests by comparing with digital subtraction angiography as a reference standard. METHODS:We performed CDU, BFI, and digital subtraction angiography on 95 consecutive patients with ICAS. Separate and combined test results of CDU and BFI were compared with digital subtraction angiography results. RESULTS: For identifying 70% to 99% ICAS, as CDU criterion, the ratio of internal carotid artery to common carotid artery peak systolic velocity had the highest diagnostic accuracy (sensitivity, 94%; specificity, 96%). The sensitivity and specificity of BFI were 65% and 98%, respectively. With CDU and BFI, results were concordant in 144 (89%) cases for 70% to 99% ICAS. Sensitivity and specificity of combined CDU and BFI results for identification of WAS were 95% and 99%, respectively. The misclassification rates of CDU and BFI were 4.7% and 8.1%, respectively. When combined test results were concordant, the misclassification rate decreased to 1.4%. CONCLUSION. CDU showed a slightly better accuracy than did BFI in the diagnosis of carotid artery stenosis. Combined use of CDU and BFI is more accurate than use of either test alone.
引用
下载
收藏
页码:1856 / 1860
页数:5
相关论文
共 50 条
  • [1] B-flow and color-coded B-flow in sonographic diagnosis of filiform stenosis of the internal carotid artery
    Jung, EM
    Clevert, DA
    Rupp, N
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (09): : 1251 - 1258
  • [2] Color Duplex Ultrasonography for the Evaluation of Innominate, Subclavian, and Common Carotid Artery Stenosis
    Zhang, Jie
    Wu, Dianze
    Wang, Shaopeng
    Bai, Liyang
    Meng, Yan
    Wang, Lijuan
    JOURNAL OF ULTRASOUND IN MEDICINE, 2024, 43 (09) : 1695 - 1709
  • [3] Evaluation of blood flow in carotid artery stenosis using B-flow sonography
    Mikami, T
    Takahashi, A
    Houkin, K
    NEUROLOGIA MEDICO-CHIRURGICA, 2003, 43 (11) : 528 - 532
  • [5] Evaluation of carotid artery stenosis: Is duplex ultrasonography sufficient
    Muto, PM
    Welch, HJ
    Mackey, WC
    ODonnell, TF
    JOURNAL OF VASCULAR SURGERY, 1996, 24 (01) : 17 - 24
  • [6] Evaluation of blood flow in carotid artery stenosis using B-flow sonography - Commentary
    Barrow, DL
    NEUROLOGIA MEDICO-CHIRURGICA, 2003, 43 (11) : 533 - 533
  • [7] Evaluation of the Ophtalmic Artery Flow Pattern with Color-Doppler Ultrasonography in the Patients with Carotid Artery Stenosis
    Demir, Senay
    Akgul, Erol
    Aikimbaev, Kairgeldy
    Tokmak, Naime
    Inal, Mehmet
    Aksungur, Erol
    CUKUROVA MEDICAL JOURNAL, 2015, 40 (04): : 730 - 737
  • [8] B-flow evaluation of carotid arterial stenosis: Initial experience
    Bucek, RA
    Reiter, M
    Koppensteiner, I
    Ahmadi, R
    Minar, E
    Lammer, J
    RADIOLOGY, 2002, 225 (01) : 295 - 299
  • [9] Ophthalmic artery flow direction on color flow duplex imaging is highly specific for severe carotid stenosis
    Reynolds, PS
    Greenberg, JP
    Lien, LM
    Meads, DC
    Myers, LG
    Tegeler, CH
    JOURNAL OF NEUROIMAGING, 2002, 12 (01) : 5 - 8
  • [10] Transoral Carotid Ultrasonography Using A Micro Convex Probe with B-flow Imaging for Extracranial Internal Carotid Artery Dissection
    Sakima, Hirokuni
    Isa, Katsunori
    Anegawa, Takahiro
    Kokuba, Kazuhito
    Nakachi, Koh
    Goya, Yoshino
    Tokashiki, Takashi
    Ishiuchi, Shogo
    Ohya, Yusuke
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2012, 21 (08):