Comparison of 3D double inversion recovery and 2D STIR FLAIR MR sequences for the imaging of optic neuritis: pilot study

被引:42
|
作者
Hodel, Jerome [1 ]
Outteryck, Olivier [2 ]
Bocher, Anne-Laure [1 ]
Zephir, Helene [2 ]
Lambert, Oriane [3 ]
Benadjaoud, Mohamed Amine [4 ]
Chechin, David [5 ]
Pruvo, Jean-Pierre [1 ]
Vermersch, Patrick [2 ]
Leclerc, Xavier [1 ]
机构
[1] Hop Roger Salengro, Dept Neuroradiol, F-59037 Lille, France
[2] Hop Roger Salengro, Dept Neurol, F-59037 Lille, France
[3] Fdn Ophtalmol Rothschild, Dept Neuroradiol, Paris, France
[4] INSERM, CESP Ctr Res Epidemiol & Populat Hlth, U1018, Radiat Epidemiol Team, Villejuif, France
[5] Philips Med Syst, Suresnes, France
关键词
Multiple sclerosis; Neuromyelitis optica; Clinically isolated syndrome; Optic neuritis; Double inversion recovery MR sequence; MULTIPLE-SCLEROSIS; INTRACORTICAL LESIONS; 7; TESLA; NERVE; CSF; SPECIFICITY; SENSITIVITY; ARTIFACTS; 3D-FLAIR; CONTRAST;
D O I
10.1007/s00330-014-3342-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We compared the three-dimensional (3D) double inversion recovery (DIR) magnetic resonance imaging (MRI) sequence with the coronal two-dimensional (2D) short tau inversion recovery (STIR) fluid-attenuated inversion recovery (FLAIR) for the detection of optic nerve signal abnormality in patients with optic neuritis (ON). The study group consisted of 31 patients with ON (44 pathological nerves) confirmed by visual-evoked potentials used as the reference. MRI examinations included 2D coronal STIR FLAIR and 3D DIR with 3-mm coronal reformats to match with STIR FLAIR. Image artefacts were graded for each portion of the optic nerves. Each set of MR images (2D STIR FLAIR, DIR reformats and multiplanar 3D DIR) was examined independently and separately for the detection of signal abnormality. Cisternal portion of optic nerves was better delineated with DIR (p < 0.001), while artefacts impaired analysis in four patients with STIR FLAIR. Inter-observer agreement was significantly improved (p < 0.001) on 3D DIR (kappa = 0.96) compared with STIR FLAIR images (kappa = 0.60). Multiplanar DIR images reached the best performance for the diagnosis of ON (95 % sensitive and 94 % specific). Our study showed a high sensitivity and specificity of 3D DIR compared with STIR FLAIR for the detection of ON. These findings suggest that the 3D DIR sequence may be more useful in patients suspected of ON. aEuro cent 3D DIR is increasingly used in neuroradiology aEuro cent Compared with STIR FLAIR, 3D DIR improves detection of optic neuritis aEuro cent Multiplanar analysis had the best diagnostic performance for optic nerve signal abnormalities aEuro cent Sensitivity was 95 % and specificity 94 % aEuro cent Findings support the use of 3D DIR instead of 2D sequences.
引用
收藏
页码:3069 / 3075
页数:7
相关论文
共 50 条
  • [1] Comparison of 3D double inversion recovery and 2D STIR FLAIR MR sequences for the imaging of optic neuritis: pilot study
    Jérôme Hodel
    Olivier Outteryck
    Anne-Laure Bocher
    Hélène Zéphir
    Oriane Lambert
    Mohamed Amine Benadjaoud
    David Chechin
    Jean-Pierre Pruvo
    Patrick Vermersch
    Xavier Leclerc
    European Radiology, 2014, 24 : 3069 - 3075
  • [2] Comparison of 3D Double Inversion Recovery (DIR) versus 3D Fluid Attenuated Inversion Recovery (FLAIR) in precise diagnosis of acute optic neuritis
    Murumkar, Vivek
    Baishya, Priyanka Priyadarshini
    Kulanthaivelu, Karthik
    Saini, Jitender
    Manjunath, Netravathi
    Gupta, Rakesh Kumar
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 155
  • [3] Comparison of 3D FLAIR, 2D FLAIR, and 2D T2-Weighted MR Imaging of Brain Stem Anatomy
    Kitajima, M.
    Hirai, T.
    Shigematsu, Y.
    Uetani, H.
    Iwashita, K.
    Morita, K.
    Komi, M.
    Yamashita, Y.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (05) : 922 - 927
  • [4] Pitfalls of 3D FLAIR Brain Imaging: A Prospective Comparison with 2D FLAIR
    Kakeda, Shingo
    Korogi, Yukunori
    Hiai, Yasuhiro
    Ohnari, Norihiro
    Sato, Toru
    Hirai, Toshinori
    ACADEMIC RADIOLOGY, 2012, 19 (10) : 1225 - 1232
  • [5] Comparison of Modern 3D and 2D MR Imaging Sequences of the Wrist at 3 Tesla
    Rehnitz, C.
    Klaan, B.
    von Stillfried, F.
    Amarteifio, E.
    Burkholder, I.
    Kauczor, H. U.
    Weber, M. A.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (08): : 753 - 762
  • [6] Comparison of 3D Cube FLAIR with 2D FLAIR for Multiple Sclerosis Imaging at 3 Tesla
    Patzig, M.
    Burke, M.
    Brueckmann, H.
    Fesl, G.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (05): : 484 - 488
  • [7] Determination of Efficiency of 3D Fluid-Attenuated Inversion Recovery (FLAIR) in the Imaging of Multiple Sclerosis in Comparison With 2D FLAIR at 3-Tesla MRI
    Kummari, Satyanarayana
    Burra, Kiran Goud
    Reddy, Vudem Ranjith Kumar
    Das, Saraswata
    Anilkumar, Challa
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (11)
  • [8] Magnetic resonance imaging of focal cortical dysplasia: Comparison of 3D and 2D fluid attenuated inversion recovery sequences at 3 T
    Tschampa, Henriette J.
    Urbach, Horst
    Malter, Michael
    Surges, Rainer
    Greschus, Susanne
    Gieseke, Juergen
    EPILEPSY RESEARCH, 2015, 116 : 8 - 14
  • [9] Sensitivity of 2D and 3D GRE sequences in dynamic breast MR imaging: Systematic controlled study with intraindividual comparison
    Kuhl, CK
    Mielcarek, P
    Schild, HH
    RADIOLOGY, 1996, 201 : 8 - 8
  • [10] Assessment of pituitary microadenomas: Comparison between 2D and 3D MR sequences
    Magnaldi, S
    Frezza, F
    Longo, R
    Ukmar, M
    Razavi, IS
    PozziMucelli, RS
    MAGNETIC RESONANCE IMAGING, 1997, 15 (01) : 21 - 27