Electro-Fenton method for the removal of Malachite Green: effect of operational parameters

被引:55
|
作者
Teymori, Maryam [1 ]
Khorsandi, Hassan [1 ]
Aghapour, Ali Ahmad [1 ]
Jafari, Seyed Javad [1 ]
Maleki, Ramin [2 ]
机构
[1] Urmia Univ Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Orumiyeh, Iran
[2] Iranian Acad Ctr Educ Culture & Res ACECR, Res Dept Chromatog, Orumiyeh, Iran
关键词
Advanced oxidation process; Degradation; Electro-Fenton; Malachite Green; WASTE-WATER; PHOTO-FENTON; ELECTROCHEMICAL OXIDATION; AZO-DYE; DEGRADATION; ELECTROCOAGULATION; DECOLORIZATION; MINERALIZATION; BIODEGRADATION; FORMALDEHYDE;
D O I
10.1007/s13201-019-1123-5
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
This study aims to evaluate the degradation and mineralization of Malachite Green (MG) in an electro-Fenton process (EFP). We studied the influence of several important parameters including solution pH (2-11), current density (0-20 mA/cm(2)), H2O2 concentration (0-200 mg/L) and MG concentrations (200, 600, 1000, 1500, 2000, 3000 mg/L) at different reaction time (2.5-30 min). The intermediates produced during the degradation were determined by GC-MS. The optimum pH, current density and H2O2 concentration were found to be approximately 3, 10 mA/cm(2) and 50 mg/L, respectively. It was concluded that acidic pH was required to increase the efficiency of the EFP. At optimum conditions and a reaction time of 15 min, MG was completely removed without any significant variation in the corresponding maximum wavelengths or new absorption bands. Due to formation of intermediates, almost all the organic compounds were completely mineralized (95.3%) to CO2 and water at reaction time of 30 min. Results indicated the effect of hydroxyl radical ((OH)-O-center dot) on MG degradation is greater than that of superoxide radical scavenger (O2 center dot-). The results showed that the degradation process of MG followed pseudo-first-order kinetic model and the treatment time required in EFP was 4.6 times lower than ECP. Furthermore, the results showed that EFP was an extremely efficient process for degradation and mineralization of a high concentration of MG (1000 mg/L) at a short reaction time (30 min).
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Electro-Fenton method for the removal of Malachite Green: effect of operational parameters
    Maryam Teymori
    Hassan Khorsandi
    Ali Ahmad Aghapour
    Seyed Javad Jafari
    Ramin Maleki
    Applied Water Science, 2020, 10
  • [2] Laboratory study of the silica removal in water by electro-Fenton method: Effect of operational parameters
    Djouider, Fathi
    Banoqitah, Essam
    Alhawsawi, Abdulsalam
    DESALINATION AND WATER TREATMENT, 2024, 317
  • [3] Experimental study of photo electro-Fenton method for the removal of Reactive Yellow 186: Influence of operational parameters
    Elumalai, Gomathi
    Sowmya, B.
    Rajan, Rajesh Kannan
    Shanmugam, Venkatkumar
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2023, 42 (03)
  • [4] Heterogeneous Electro-Fenton as "Green" Technology for Pharmaceutical Removal: A Review
    Meijide, Jessica
    Dunlop, Patrick S. M.
    Pazos, Marta
    Sanroman, Maria Angeles
    CATALYSTS, 2021, 11 (01) : 1 - 22
  • [5] Electro-Fenton/peracetic acid process for the removal of Rhodamine B dye from aqueous media: effect of operational parameters and optimization with Taguchi method
    Rahmani, Alireza
    Gilani, Roya Azami
    Dargahi, Abdollah
    Faradmal, Javad
    DESALINATION AND WATER TREATMENT, 2023, 297 : 254 - 263
  • [6] A feasible electro-Fenton treatment of landfill leachate diluted by electro-Fenton effluent: Evaluation of operational parameters, effect of dilution ratio and assessment of treatment cost
    Li, Mingran
    Zhou, Mengnan
    Qin, Xia
    JOURNAL OF WATER PROCESS ENGINEERING, 2022, 47
  • [7] Oxidation pathways of malachite green by Fe3+-catalyzed electro-Fenton process
    Oturan, Mehmet A.
    Guivarch, Elodie
    Oturan, Nihal
    Sires, Ignasi
    APPLIED CATALYSIS B-ENVIRONMENTAL, 2008, 82 (3-4) : 244 - 254
  • [8] Effect of parameters on electro-Fenton process for removal of oil and grease from refinery wastewater
    Vikramaraj, Mikhila
    Manilal, A. M.
    Soloman, P. A.
    EMERGING TRENDS IN ENGINEERING, SCIENCE AND TECHNOLOGY FOR SOCIETY, ENERGY AND ENVIRONMENT, 2018, : 523 - 529
  • [9] Removal of COD from landfill leachate by electro-Fenton method
    Zhang, Hui
    Zhang, Daobin
    Zhou, Jiayong
    JOURNAL OF HAZARDOUS MATERIALS, 2006, 135 (1-3) : 106 - 111
  • [10] Influence of operational parameters on electro-Fenton degradation of organic pollutants from soil
    Rosales, E.
    Pazos, M.
    Longo, M. A.
    Sanroman, M. A.
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2009, 44 (11): : 1104 - 1110