In situ study of ligand-receptor interaction by total internal reflection ellipsometry

被引:28
|
作者
Balevicius, Z. [1 ,3 ]
Baleviciute, I. [2 ]
Tumenas, S. [1 ]
Tamosaitis, L. [1 ,2 ]
Stirke, A. [1 ]
Makaraviciute, A. [1 ,2 ]
Ramanaviciene, A. [2 ]
Ramanavicius, A. [1 ,2 ]
机构
[1] State Res Inst, Ctr Phys Sci & Technol, Savanoriu Ave 231, LT-01108 Vilnius, Lithuania
[2] Vilnius Univ, Fac Chem, LT-03225 Vilnius, Lithuania
[3] Vilnius Gediminas Tech Univ, Fac Elect, LT-10223 Vilnius, Lithuania
关键词
In situ spectroscopic ellipsometry; SPR enchanced ellipsometry; Total internal reflection ellipsometry; Ligand-receptor interaction; Granulocyte colony stimulating factor (GCSF); ANTIBODY IMMOBILIZATION TECHNIQUES; PHASE;
D O I
10.1016/j.tsf.2013.10.090
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Spectroscopic total internal reflection ellipsometry (TIRE) in its dynamic data acquisition mode has been applied for the in situ study of the interactions of monomeric (mGCSF) and dimeric (dGCSF) granulocyte colony stimulating factor and its receptor (GCSF-R) which was immobilized on a thin gold layer. Regression results have shown that the account for signal non-linearity due to analysis of spectroscopic dynamic TIRE data has allowed us to detect small differences in association and dissociation times through the precise determination of the refractive index dispersion. Different binding models were applied in the study of mGCSF and dGCSF interaction with a monolayer of its receptor GCSF-R due to their distinctive changes of refractive index over time. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:744 / 748
页数:5
相关论文
共 50 条
  • [1] Ligand-receptor kinetics measured by total internal reflection with fluorescence correlation spectroscopy
    Lieto, AM
    Cush, RC
    Thompson, NL
    BIOPHYSICAL JOURNAL, 2003, 85 (05) : 3294 - 3302
  • [2] Ligand-receptor kinetics measured by total internal reflection with fluorescence correlation spectroscopy
    Lieto, AM
    Cush, RC
    Starr, TE
    Thompson, NL
    BIOPHYSICAL JOURNAL, 2003, 84 (02) : 587A - 587A
  • [3] Total internal reflection ellipsometry - A tool for in-situ corrosion studies
    Poksinski, M
    Dzuho, H
    Arwin, H
    CORROSION AND CORROSION PROTECTION, 2001, 2001 (22): : 1002 - 1008
  • [4] Study of the Interaction Between Biomolecule Mono layers Using Total Internal Reflection Ellipsometry
    Jung, Yong Woo
    Yoon, Jae Jin
    Kim, Young Dong
    Woo, Deokha
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 58 (04) : 1031 - 1034
  • [5] Study of the interaction between HSA and oligo-DNA using total internal reflection ellipsometry
    Y. W. Jung
    J. S. Byun
    Y. D. Kim
    D. Hemzal
    J. Humliček
    Journal of the Korean Physical Society, 2012, 60 : 1288 - 1291
  • [6] Study of the Interaction Between HSA and Oligo-DNA Using Total Internal Reflection Ellipsometry
    Jung, Y. W.
    Byun, J. S.
    Kim, Y. D.
    Hemzal, D.
    Humlicek, J.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 60 (08) : 1288 - 1291
  • [7] Total internal reflection ellipsometry based SPR sensor for studying biomolecular interaction
    Pant, Udit
    Mohapatra, Saswat
    Moirangthem, Rakesh S.
    MATERIALS TODAY-PROCEEDINGS, 2020, 28 : 254 - 257
  • [8] Total internal reflection ellipsometry of periodic structures
    Pistora, J
    Vlcek, J
    Hlubina, P
    Foldyna, M
    Zivotsky, O
    PHOTONICS, DEVICES, AND SYSTEMS III, 2006, 6180
  • [9] Total internal reflection ellipsometry: principles and applications
    Arwin, H
    Poksinski, M
    Johansen, K
    APPLIED OPTICS, 2004, 43 (15) : 3028 - 3036
  • [10] Potential Modulation on Total Internal Reflection Ellipsometry
    Liu, Wei
    Niu, Yu
    Viana, A. S.
    Correia, Jorge P.
    Jin, Gang
    ANALYTICAL CHEMISTRY, 2016, 88 (06) : 3211 - 3217