Intensity-sensitive and position-resolving cavity for heavy-ion storage rings

被引:16
|
作者
Chen, X. [1 ,2 ]
Sanjari, M. S. [1 ]
Huelsmann, P. [1 ]
Litvinov, Yu. A. [1 ,3 ]
Nolden, F. [1 ]
Piotrowski, J. [4 ]
Steck, M. [1 ]
Stoehlker, Th. [1 ,5 ]
Walker, P. M. [6 ]
机构
[1] GSI Helmholtzzentrum Schwerionenforsch, D-64291 Darmstadt, Germany
[2] Heidelberg Univ, D-69120 Heidelberg, Germany
[3] Max Planck Inst Kernphys, D-69117 Heidelberg, Germany
[4] AGH Univ Sci & Technol, PL-30059 Krakow, Poland
[5] Helmholtz Inst Jena, D-07743 Jena, Germany
[6] Univ Surrey, Dept Phys, Guildford GU2 7XH, Surrey, England
基金
英国科学技术设施理事会;
关键词
Intensity-sensitive; Position-resolving; Cavity; Storage ring; MASS;
D O I
10.1016/j.nima.2016.04.056
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A heavy-ion storage ring can be adapted for use as an isochronous mass spectrometer if the ion velocity matches the transition energy of the ring. Due to the variety of stored ion species, the isochronous condition cannot be fulfilled for all the ions. In order to eliminate the measurement uncertainty stemming from the velocity spread, an intensity-sensitive and position-resolving cavity is proposed. In this paper we first briefly discuss the correction method for the anisochronism effect in the measurement with the cavity. Then we introduce a novel design, which is operated in the monopole mode and offset from the central beam orbit to one side. The geometrical parameters were optimized by analytic and numerical means in accordance with the beam dynamics of the future collector ring at FAIR. Afterwards, the electromagnetic properties of scaled prototypes were measured on a test bench. The results were in good agreement with the predictions. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:39 / 47
页数:9
相关论文
共 50 条
  • [1] Position sensitive resonant Schottky cavities for heavy ion storage rings
    Dmytriiev, D.
    Sanjari, M. S.
    Litvinov, Yu. A.
    Stoehlker, Th.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2020, 463 : 320 - 323
  • [2] Heavy-ion injection in synchrotrons and storage rings
    Dinev, D
    PHYSICS OF PARTICLES AND NUCLEI, 1997, 28 (02) : 180 - 197
  • [3] PRECISION EXPERIMENTS WITH HEAVY-ION STORAGE RINGS
    Litvinov, Yuri A.
    Glorius, Jan
    Steck, Markus
    Stoehlker, Thomas
    Blaum, Klaus
    Bruno, Carlo Giulio
    Woods, Philip J.
    Dillmann, Iris
    Jurado, Beatriz
    Korten, Wolfram
    Ma, Xinwen
    Zhang, Yuhu
    Reifarth, Rene
    Walker, Philip M.
    Yamaguchi, Takayuki
    ACTA PHYSICA POLONICA B PROCEEDINGS SUPPLEMENT, 2023, 16 (04)
  • [4] HEAVY-ION STORAGE-RINGS FOR ATOMIC PHYSICS
    FRANZKE, B
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (05) : 3297 - 3301
  • [5] ATOMIC PHYSICS IN HEAVY-ION STORAGE-RINGS
    HVELPLUND, P
    JOURNAL DE PHYSIQUE, 1989, 50 (C-1): : 459 - 470
  • [6] STABILIZATION OF LONGITUDINAL INSTABILITIES IN HEAVY-ION STORAGE RINGS.
    Zenkevich, P.R.
    Koshkarev, D.G.
    Instruments and experimental techniques New York, 1982, 25 (4 pt 1): : 817 - 821
  • [7] EXPERIMENTAL ATOMIC PHYSICS IN HEAVY-ION STORAGE-RINGS
    DATZ, S
    ANDERSEN, LH
    BRIAND, JP
    LIESEN, D
    PHYSICA SCRIPTA, 1988, T22 : 224 - 227
  • [8] STABILIZATION OF LONGITUDINAL INSTABILITIES IN HEAVY-ION STORAGE-RINGS
    ZENKEVICH, PR
    KOSHKAREV, DG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1982, 25 (04) : 817 - 821
  • [9] RESOLVING AMBIGUITIES IN HEAVY-ION POTENTIALS
    GOLDBERG, DA
    SMITH, SM
    PHYSICAL REVIEW LETTERS, 1974, 33 (12) : 715 - 718
  • [10] HEAVY-ION ACCELERATORS AND STORAGE-RINGS FOR PELLET FUSION REACTORS
    MARTIN, RL
    ARNOLD, RC
    NUCLEAR INSTRUMENTS & METHODS, 1978, 155 (03): : 337 - 345