Non-invasive Glucose Monitoring Based on Optical Coherent Tomography

被引:0
|
作者
Chen, Tseng-Lin [1 ]
Lo, Yu-Lung [1 ,2 ]
Quoc-Hung Phan [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Mech Engn, Tainan 701, Taiwan
[2] Natl Cheng Kung Univ, Adv Optoelect Technol Ctr, Tainan 701, Taiwan
来源
关键词
Mueller matrix Polarimetry; glucose sensing; optical rotation angle; degree of depolarization;
D O I
10.1117/12.2303362
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A novel technique based on optical coherence tomography (OCT) for noninvasive glucose monitoring is proposed. The feasibility of the proposed technique is demonstrated by detecting the glucose concentration of aqueous solution ranging from 0-4000 mg/dL with 0.02% lipofundin. The practical applicability of the proposed technique is demonstrated by detecting the glucose concentration of the human fingertip tissue based on the oral glucose tolerance test (OGTT).
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Optical coherence tomography-based continuous non-invasive glucose monitoring in patients with diabetes
    Gabbay, Robert
    Sivarajah, Surendra
    Wilkins, Robert
    Schurman, Matthew
    [J]. DIABETES, 2007, 56 : A108 - A108
  • [2] Potential application of optical coherence tomography for non-invasive monitoring of glucose concentration
    Larin, K
    Larina, I
    Motamedi, M
    Gelikonov, V
    Kuranov, R
    Esenaliev, R
    [J]. OPTICAL DIAGNOSTICS AND SENSING OF BIOLOGICAL FLUIDS AND GLUCOSE AND CHOLESTEROL MONITORING, 2001, 4263 : 83 - 90
  • [3] Non-invasive glucose monitoring
    Arnold, MA
    [J]. CURRENT OPINION IN BIOTECHNOLOGY, 1996, 7 (01) : 46 - 49
  • [4] MICROWAVES BASED SENSORS FOR NON-INVASIVE GLUCOSE MONITORING
    Salem, Enjy Mohamed
    Elsheakh, Dalia N.
    Eldamak, Angie R.
    [J]. PROCEEDINGS OF 2022 39TH NATIONAL RADIO SCIENCE CONFERENCE (NRSC'2022), 2022, : 273 - 279
  • [5] Electromagnetic Based Devices for Non-invasive Glucose Monitoring
    Hanna, J.
    Costantine, J.
    Kanj, R.
    Eid, A.
    Tawk, Y.
    Ramadan, A. H.
    [J]. 2018 IEEE CONFERENCE ON ANTENNA MEASUREMENTS & APPLICATIONS (CAMA), 2018,
  • [6] Technology for non-invasive monitoring of glucose
    Heise, HM
    [J]. PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 2159 - 2161
  • [7] Comparative Analysis of Golay Code based Excitation and Coherent Averaging for Non-Invasive Glucose Monitoring System
    Sarangi, Satyabrata
    Pai, Praful P.
    Sanki, Pradyut Kumar
    Banerjee, Swapna
    [J]. 2014 IEEE 27TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS), 2014, : 485 - 486
  • [8] AN OPTICAL APPROACH FOR BLOODLESS, IN-VITRO AND NON-INVASIVE GLUCOSE MONITORING
    Fathimal, M. Sameera
    Kirubha, S. P. Angeline
    Jeya Prabha, A.
    Jothiraj, S.
    [J]. BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2023, 35 (03):
  • [9] A Review of Non-Invasive Optical Systems for Continuous Blood Glucose Monitoring
    Alsunaidi, Bushra
    Althobaiti, Murad
    Tamal, Mahbubunnabi
    Albaker, Waleed
    Al-Naib, Ibraheem
    [J]. SENSORS, 2021, 21 (20)
  • [10] Voltage Intensity Based Non-Invasive Blood Glucose Monitoring
    Menon, K. A. Unnikrishna
    Hemachandran, Deepak
    Kunnath, Abishek Thekkeyil
    [J]. 2013 FOURTH INTERNATIONAL CONFERENCE ON COMPUTING, COMMUNICATIONS AND NETWORKING TECHNOLOGIES (ICCCNT), 2013,