Injection of low and iso-osmolar contrast medium decreases oxygen tension in the renal medulla

被引:113
|
作者
Liss, P [1 ]
Nygren, A
Erikson, U
Ulfendahl, HR
机构
[1] Univ Uppsala Hosp, Dept Diagnost Radiol, S-75185 Uppsala, Sweden
[2] Univ Uppsala, Dept Physiol & Med Biophys, S-75105 Uppsala, Sweden
关键词
contrast media; oxygen tension; kidney; medulla; hypoxia; acute renal failure; radiocontrast toxicity;
D O I
10.1046/j.1523-1755.1998.00811.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
The oxygen tension (PO2) in the renal cortex and outer renal medulla in 26 rats was studied by use of microelectrodes before and after injection of x-ray contrast media The CMI iopromide. ioxaglate and iotrolan were administrated intravenously in iodine equivalent doses (1,600 mg iodine/kg body wt). Ringer's solution was used as the control. In the outer medulla, all three CM induced a decrease in PO2: iopromide (N = 6) from 30 +/- 3 to 18 +/- 4 mm Hg; ioxaglate (N = 7) from 32 +/- 6 to 15 +/- 4 mm Hg; and iotrolan (N = 6) from 36 +/- 3 to 14 +/- 4 mm Hg. Ali these decreases were significant. After the injection of Ringer's (N = 7) there was an increase from 34 +/- 3 to 35 +/- 3 mm Hg. In the cortex a slight decrease was noted after injection of CM, but this was significant only after injection of iotrolan. All tested contrast media decrease PO2 in the outer renal medulla, which may partly explain contrast medium-induced acute renal failure.