Design and Research on Parameter of LCL Filter in Three-Phase Grid-Connected Inverter

被引:0
|
作者
Liu, Fie [1 ]
Zha, Xiaoming [1 ]
Zhou, Yan [2 ]
Duan, Shanxu [2 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
[2] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, Wuhan 430074, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Since LCL filter has smaller inductance value comparing to L type filter with the same performance in harmonic suppression. it is gradually used in high-power and low-frequency current-source-controlled grid-connected converters. However design of LCL filter's parameter not only relates switch frequency ripple attenuation, but also impacts on performance of grid-connected current controller. This paper firstly introduced a harmonic model of LCL filter in grid-connected operation, then researched the variable relationship among LCL filter's parameter and resonance frequency and high-frequency ripple attenuation. Based on above analysis a reasonable design method was brought out in order to achieve optimal effect under the precondition of saving inductance magnetic core of LCL filter, at the same time guaranteeing the resonance frequency of LCL filter was not too small lest restrict current controller resign. Finally this design method was verified by the experimental results.
引用
收藏
页码:1224 / +
页数:2
相关论文
共 50 条
  • [1] Research on Three-phase PV Grid-connected Inverter Based on LCL Filter
    Yin, Wenjiao
    Ma, Yundong
    [J]. PROCEEDINGS OF THE 2013 IEEE 8TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2013, : 1279 - 1283
  • [2] Design and Control for Three-phase Grid-connected Photovoltaic Inverter with LCL Filter
    Chen, Yun
    Liu, Fei
    [J]. IEEE CIRCUITS AND SYSTEMS INTERNATIONAL CONFERENCE ON TESTING AND DIAGNOSIS, 2009, : 399 - 402
  • [3] LCL Filter Design for Grid Connected Three-Phase Inverter
    Dursun, Mustafa
    Dosoglu, M. Kenan
    [J]. 2018 2ND INTERNATIONAL SYMPOSIUM ON MULTIDISCIPLINARY STUDIES AND INNOVATIVE TECHNOLOGIES (ISMSIT), 2018, : 67 - 70
  • [4] Control Parameter Design of Three-Phase Grid Connected Inverter Based on LCL Filter
    Zhong, Jianying
    Wei, Yitao
    Yang, Baoxin
    Cheng, Tiehan
    Xu, Jianyuan
    Yan, Zheng
    [J]. 2021 11TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY SYSTEMS (ICPES 2021), 2021, : 269 - 274
  • [5] Decouple Control Strategy of Three-Phase Grid-Connected Inverter with LCL Filter
    Xian, Jiaheng
    Zhang, Hui
    Tan, Li
    [J]. PROCEEDINGS OF THE 2018 13TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2018), 2018, : 238 - 242
  • [6] Optimal Digital Controller Design for Passive Stabilization of a Grid-Connected Three-Phase Inverter with LCL filter
    Kato, Toshiji
    Inoue, Kaoru
    Yamamoto, Yuki
    [J]. 2019 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2019, : 455 - 461
  • [7] LCL-Filter Design for Grid-Connected Three-Phase Inverter Using Space Vector PWM
    Seo, SeungGyu
    Cho, Yongsoo
    Lee, Kyo-Beum
    [J]. 2016 IEEE 8TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC-ECCE ASIA), 2016, : 389 - 394
  • [8] A Full-Feedforward Scheme of Grid Voltages for a Three-Phase Grid-Connected Inverter With an LCL Filter
    Li, Weiwei
    Pan, Donghua
    Ruan, Xinbo
    Wang, Xuehua
    [J]. 2011 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2011, : 96 - 103
  • [9] Design and analysis of an LCL circuit-based three-phase grid-connected inverter
    Liu, Jinhong
    Zhou, Lin
    Yu, Xirui
    Li, Bin
    Zheng, Chen
    [J]. IET POWER ELECTRONICS, 2017, 10 (02) : 232 - 239
  • [10] Model Predictive Control of Three-phase Grid-connected Voltage Source Inverter with LCL Filter
    Yin, Hang
    Zhou, Yuzhen
    Lan, Yuanliang
    Lan, Tian
    Wu, Xiang
    Lei, Xianzhang
    [J]. 2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 2204 - 2209