Simultaneous Dose and Dose Rate Optimization with Transmission Beams and Bragg Peaks for Proton FLASH Therapy

被引:0
|
作者
Lin, Y. [1 ]
Lin, B. [1 ,2 ]
Fu, S. [2 ]
Folkerts, M. [3 ]
Abel, E. [3 ]
Bradley, J. [1 ]
Gao, H. [1 ]
机构
[1] Emory Univ, Winship Canc Inst, Atlanta, GA 30322 USA
[2] Shandong Univ, Jinan, Shandong, Peoples R China
[3] Varian Med Syst, Palo Alto, CA USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-IePD-TR
引用
收藏
页数:2
相关论文
共 50 条
  • [1] SDDRO-joint: simultaneous dose and dose rate optimization with the joint use of transmission beams and Bragg peaks for FLASH proton therapy
    Lin, Yuting
    Lin, Bowen
    Fu, Shujun
    Folkerts, Michael M.
    Abel, Eric
    Bradley, Jeffery
    Gao, Hao
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (12):
  • [2] Simultaneous dose and dose rate optimization (SDDRO) for FLASH proton therapy
    Gao, Hao
    Lin, Bowen
    Lin, Yuting
    Fu, Shujun
    Langen, Katja
    Liu, Tian
    Bradley, Jeffery
    [J]. MEDICAL PHYSICS, 2020, 47 (12) : 6388 - 6395
  • [3] Dose and dose rate objectives in Bragg peak and shoot-through beam orientation optimization for FLASH proton therapy
    Ramesh, Pavitra
    Gu, Wenbo
    Ruan, Dan
    Sheng, Ke
    [J]. MEDICAL PHYSICS, 2022, 49 (12) : 7826 - 7837
  • [4] Simultaneous dose and dose rate optimization (SDDRO) of the FLASH effect for pencil-beam-scanning proton therapy
    Gao, Hao
    Liu, Jiulong
    Lin, Yuting
    Gan, Gregory N
    Pratx, Guillem
    Wang, Fen
    Langen, Katja
    Bradley, Jeffrey D
    Rotondo, Ronny L
    Li, Harold H
    Chen, Ronald C
    [J]. Medical Physics, 2022, 49 (03): : 2014 - 2025
  • [5] Simultaneous dose and dose rate optimization (SDDRO) of the FLASH effect for pencil-beam-scanning proton therapy
    Gao, Hao
    Liu, Jiulong
    Lin, Yuting
    Gan, Gregory N.
    Pratx, Guillem
    Wang, Fen
    Langen, Katja
    Bradley, Jeffrey D.
    Rotondo, Ronny L.
    Li, Harold H.
    Chen, Ronald C.
    [J]. MEDICAL PHYSICS, 2022, 49 (03) : 2014 - 2025
  • [6] BEST IN PHYSICS (THERAPY): Dose and Dose Rate Optimization for FLASH Proton Therapy with Automated Bragg Peak and Shoot-Through Beam Selection
    Ramesh, P.
    Gu, W.
    Ruan, D.
    Sheng, K.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E567 - E568
  • [7] FLASH-Enabled Proton SBRT/SRS via Simultaneous Dose and Dose Rate Optimization (SDDRO)
    Gao, H.
    Lin, Y.
    Gan, G. N.
    Wang, F.
    Li, H.
    Chen, R. C.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 114 (03): : E571 - E572
  • [8] An Effective Dose Rate Optimization Algorithm for Efficient Conventional-Dose-Rate Proton Therapy and Ultra-High Dose-Rate FLASH Proton Therapy
    Zhu, Y. N.
    Zhang, X.
    Lin, Y.
    Lominska, C.
    Gao, H.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : S37 - S38
  • [9] SDDRO-PBS: Simultaneous Dose and Dose Rate Optimization for FLASH Proton SBRT Based on Pencil Beam Scanning Dose Rate Modeling
    Gao, H.
    Folkerts, M. M.
    Lin, Y.
    Abel, E.
    Bradley, J. D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E553 - E553
  • [10] Simultaneous dose and dose rate optimization via dose modifying factor modeling for FLASH effective dose
    Ma, Jiangjun
    Lin, Yuting
    Tang, Min
    Zhu, Ya-Nan
    Gan, Gregory N.
    Rotondo, Ronny L.
    Chen, Ronald C.
    Gao, Hao
    [J]. MEDICAL PHYSICS, 2024, 51 (08) : 5190 - 5203