Semi-blind ICA of FMRI: A method for utilizing hypothesis-derived time courses in a spatial ICA analysis

被引:0
|
作者
Calhoun, V [1 ]
Adali, T [1 ]
机构
[1] Olin Neuropsychiat Res Ctr, Inst Living, Hartford, CT 06106 USA
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Independent component analysis (ICA), a data-driven approach utilizing high-order statistical moments to find maximally independent sources, has found fruitful application in functional magnetic resonance imaging (fMRI). ICA, being a blind source separation technique, does not require any explicit constraints upon the fMRI time courses. In some cases, such as for the analysis of a rapid event-related paradigm, it would be useful to incorporate paradigm information into the ICA analysis in a flexible way. In this paper, we present an approach for constrained or semi-blind ICA (sbICA) analysis of fMRI data. We demonstrate the performance of our approach using simulations and fMRI data of an auditory oddball paradigm. Simulation results suggest that 1) a regression approach slightly outperforms ICA when prior information is accurate and ICA outperforms the general linear modeling (GLM) approach when prior information is not completely accurate, 2) prior information improves the robustness of ICA in the presence of noise, and 3) and ICA analysis using prior information with weak constraints can outperform a regression approach when the prior information is not completely accurate.
引用
收藏
页码:443 / 452
页数:10
相关论文
共 7 条
  • [1] Semi-blind ICA of fMRI: a method for utilizing hypothesis-derived time courses in a spatial ICA analysis
    Calhoun, VD
    Adali, T
    Stevens, MC
    Kiehl, KA
    Pekar, JJ
    [J]. NEUROIMAGE, 2005, 25 (02) : 527 - 538
  • [2] Similarities between evaluative and non-evaluative judgments: A pluralistic FMRI analysis using SPM and semi-blind ICA
    Giuliani, NR
    Calhoun, VD
    Cunningham, WA
    [J]. JOURNAL OF COGNITIVE NEUROSCIENCE, 2005, : 35 - 35
  • [3] Performance of blind source separation algorithms for fMRI analysis using a group ICA method
    Correa, Nicolle
    Adali, Tulay
    Calhoun, Vince D.
    [J]. MAGNETIC RESONANCE IMAGING, 2007, 25 (05) : 684 - 694
  • [4] Adaptive semi-blind ICA-based spatial equalization for MIMO Rayleigh fading channels with optimal step size
    Ding, Zhiguo
    Ratnarajah, T.
    Cowan, Colin
    [J]. 2006 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING, VOLS 1-13, 2006, : 4495 - 4498
  • [5] Semi-Blind Independent Component Analysis of fMRI Based on Real-Time fMRI System
    Ma, Xinyue
    Zhang, Hang
    Zhao, Xiaojie
    Yao, Li
    Long, Zhiying
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2013, 21 (03) : 416 - 426
  • [6] ICA Based Semi-Blind Decoding Method for a Multicell Multiuser Massive MIMO Uplink System in Rician/Rayleigh Fading Channels
    Shen, Lei
    Yao, Yu-Dong
    Wang, Haiquan
    Wang, Huaxia
    [J]. IEEE TRANSACTIONS ON WIRELESS COMMUNICATIONS, 2017, 16 (11) : 7501 - 7511
  • [7] A Cross-Reference Method for Nonlinear Time Series Analysis in Semi-Blind Case
    杨绿溪
    何振亚
    [J]. Journal of Southeast University(English Edition), 1999, (01) : 3 - 8