Pulse-height defect in single-crystal CVD diamond detectors

被引:5
|
作者
Beliuskina, O. [1 ]
Strekalovsky, A. O. [2 ]
Aleksandrov, A. A. [2 ]
Aleksandrova, I. A. [2 ]
Devaraja, H. M. [3 ,6 ]
Heinz, C. [4 ]
Heinz, S. [4 ,5 ]
Hofmann, S. [5 ]
Ilich, S. [2 ]
Imai, N. [1 ]
Kamanin, D. V. [2 ]
Kis, M. [5 ]
Knyazheva, G. N. [2 ]
Kozhuharov, C. [5 ]
Kuznetsova, E. A. [2 ]
Maurer, J. [5 ]
Mishinsky, G. V. [2 ]
Pomorski, M. [6 ]
Pyatkov, Yu. V. [2 ]
Strekalovsky, O. V. [2 ]
Traeger, M. [5 ]
Zhuchko, V. E. [2 ]
机构
[1] Univ Tokyo, Ctr Nucl Study, Hirosawa 2-1, Wako, Saitama 3510198, Japan
[2] JINR, Flerov Lab Nucl React, Dubna, Moscow Region, Russia
[3] Manipal Univ, Manipal Ctr Nat Sci, Manipal 576014, Karnataka, India
[4] Justus Liebig Univ Giessen, Phys Inst 2, Heinrich Buff Ring 16, D-35392 Giessen, Germany
[5] GSI Helmholtzzentrum Schwerionenforsch, D-64291 Darmstadt, Germany
[6] CEA Saclay, CEA, LIST, Diamond Sensor Lab, F-91191 Gif Sur Yvette, France
来源
EUROPEAN PHYSICAL JOURNAL A | 2017年 / 53卷 / 02期
关键词
SURFACE-BARRIER DETECTOR; HEAVY-IONS; FISSION FRAGMENTS; SILICON DETECTORS; PLASMA; SPECTROSCOPY; CALIBRATION; MASS;
D O I
10.1140/epja/i2017-12223-8
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
The pulse-height versus deposited energy response of a single-crystal chemical vapor deposition (scCVD) diamond detector was measured for ions of Ti, Cu, Nb, Ag, Xe, Au, and of fission fragments of Cf-252 at different energies. For the fission fragments, data were also measured at different electric field strengths of the detector. Heavy ions have a significant pulse-height defect in CVD diamond material, which increases with increasing energy of the ions. It also depends on the electrical field strength applied at the detector. The measured pulse-height defects were explained in the framework of recombination models. Calibration methods known from silicon detectors were modified and applied. A comparison with data for the pulse-height defect in silicon detectors was performed.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Pulse-height defect in single-crystal CVD diamond detectors
    O. Beliuskina
    A. O. Strekalovsky
    A. A. Aleksandrov
    I. A. Aleksandrova
    H. M. Devaraja
    C. Heinz
    S. Heinz
    S. Hofmann
    S. Ilich
    N. Imai
    D. V. Kamanin
    M. Kis
    G. N. Knyazheva
    C. Kozhuharov
    E. A. Kuznetsova
    J. Maurer
    G. V. Mishinsky
    M. Pomorski
    Yu. V. Pyatkov
    O. V. Strekalovsky
    M. Träger
    V. E. Zhuchko
    The European Physical Journal A, 2017, 53
  • [2] Gamma sensitivity of single-crystal CVD diamond neutron detectors
    K. N. Zyablyuk
    V. A. Kolyubin
    V. N. Pashentsev
    P. G. Nedosekin
    E. M. Tyurin
    S. A. Afanas’ev
    Inorganic Materials, 2016, 52 : 262 - 267
  • [3] Gamma sensitivity of single-crystal CVD diamond neutron detectors
    Zyablyuk, K. N.
    Kolyubin, V. A.
    Pashentsev, V. N.
    Nedosekin, P. G.
    Tyurin, E. M.
    Afanas'ev, S. A.
    INORGANIC MATERIALS, 2016, 52 (03) : 262 - 267
  • [4] FORMATION OF PULSE-HEIGHT SPECTRUM OF DIAMOND DETECTORS IRRADIATED WITH ELECTRONS
    KOZLOV, SF
    KATKOV, VP
    KRUPMAN, AJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1975, NS22 (02) : 901 - 902
  • [5] Pulse height decrease in a single-crystal CVD diamond detector under gold ion beam bombardment
    Sato, Yuki
    Murakami, Hiroyuki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2015, 54 (09)
  • [6] Development of single-crystal CVD-diamond detectors for spectroscopy and timing
    Pomorski, M.
    Berdermann, E.
    Caragheorgheopol, A.
    Ciobanu, M.
    Kis, M.
    Martemiyanov, A.
    Nebel, C.
    Moritz, P.
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2006, 203 (12): : 3152 - 3160
  • [7] ANALYSIS OF SINGLE CRYSTAL PULSE-HEIGHT DISTRIBUTIONS
    CHILDERS, HM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1959, 30 (09): : 810 - 814
  • [8] IS THERE A PULSE-HEIGHT DEFECT FOR METHANE
    HAMBSCH, FJ
    VANAARLE, J
    VOGT, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 361 (1-2): : 257 - 262
  • [9] Pulse height reduction effects of single-crystal CVD diamond detector for low-energy heavy ions
    Sato, Y.
    Shimaoka, T.
    Kaneko, J. H.
    Murakami, H.
    Miyazaki, D.
    Tsubota, M.
    Chayahara, A.
    Umezawa, H.
    Shikata, S.
    EPL, 2013, 104 (02)
  • [10] Pulse height distribution and radiation tolerance of CVD diamond detectors
    Adam, W
    Berdermann, E
    Bergonzo, P
    Bertuccio, G
    Begani, F
    Borchi, E
    Brambilla, A
    Bruzzi, M
    Colledani, C
    Conway, J
    Dangelo, P
    Dabrowski, W
    Delpierre, P
    Deneuville, A
    Dulinski, W
    van Eijk, B
    Fallou, A
    Fizzotti, F
    Foulon, F
    Friedl, M
    Gan, KK
    Gheeraert, E
    Grigoriev, E
    Hallewell, G
    Han, S
    Hartjes, F
    Hrubec, J
    Husson, D
    Kagan, H
    Kania, D
    Kaplon, J
    Karl, C
    Kass, R
    Krammer, M
    Logiudice, A
    Lu, R
    Manfredotti, C
    Meier, D
    Mishina, M
    Moroni, L
    Oh, A
    Pan, LS
    Pernicka, M
    Peitz, A
    Pirollo, S
    Polesello, P
    Procario, M
    Riester, JL
    Roe, S
    Rousseau, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 447 (1-2): : 244 - 250