Estimation of indoor moisture generation rate from measurement in buildings

被引:23
|
作者
Lu, XS [1 ]
机构
[1] Helsinki Univ Technol, Lab Struct Engn & Bldg Phys, FIN-02015 Helsinki, Finland
关键词
heat and moisture transfer; moisture generation rate; numerical simulation;
D O I
10.1016/S0360-1323(02)00237-8
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The objective of this paper is to apply a heat and moisture transfer model in association with a proposed mathematical method to accurately predict moisture generation rates and to study the effects on the indoor moisture levels of different moisture generation rate patterns in buildings. The model is validated by a real test house. Result shows that a good estimation of the transient moisture generation rate can be obtained from the knowledge of the measured indoor moisture contents and the resultant effect on indoor moisture level of different indoor moisture generation rate patterns is normally negligible. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:665 / 675
页数:11
相关论文
共 50 条
  • [1] MEASUREMENT OF INDOOR RADON CONCENTRATIONS IN PUBLIC BUILDINGS
    FENYVES, EJ
    KINSLOW, RH
    HEALTH PHYSICS, 1984, 47 (01): : 204 - 204
  • [2] Modelling of heat and moisture transfer in buildings -: II.: Applications to indoor thermal and moisture control
    Lü, XS
    ENERGY AND BUILDINGS, 2002, 34 (10) : 1045 - 1054
  • [3] Indoor air quality measurement in government buildings in Hksar
    Lau, KF
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 763 - 770
  • [4] A Comparison of Measurement Methods of Indoor Ammonia in New Buildings
    Yoo, Juhee
    Seo, Sooyun
    Jang, Seoungki
    Kim, Hyeondo
    EPIDEMIOLOGY, 2011, 22 (01) : S48 - S48
  • [5] Measurement of Moisture in Wood for Application in the Restoration of Old Buildings
    Moron, Carlos
    Garcia-Fuentevilla, Luisa
    Garcia, Alfonso
    Moron, Alberto
    SENSORS, 2016, 16 (05):
  • [6] Measurement and estimation of vibration of old buildings
    Niederwanger, G
    STRUCTURAL STUDIES, REPAIRS AND MAINTENANCE OF HISTORICAL BUILDINGS VI, 1999, 6 : 67 - 76
  • [7] Preliminary results of indoor moisture excess measurements for residential and office buildings in Latvia
    Zemitis, Jurgis
    Bogdanovics, Raimonds
    12TH NORDIC SYMPOSIUM ON BUILDING PHYSICS (NSB 2020), 2020, 172
  • [8] Towards a quantitative thermography for buildings - indoor measurement ofthermal losses
    Giretti, A.
    Ansuini, R.
    Lemma, M.
    Larghetti, R.
    Di Perna, C.
    PORTUGAL SB10: SUSTAINABLE BUILDING AFFORDABLE TO ALL - LOW COST SUSTAINABLE SOLUTION, 2010, : 541 - 547
  • [9] ESTIMATION OF INDOOR GAMMA-DOSE RATE
    KARPOV, VI
    KRISIUK, EM
    HEALTH PHYSICS, 1980, 39 (05): : 819 - 821
  • [10] ESTIMATION OF DOSE-RATE FOR INDOOR RADON FROM BUILDING-MATERIALS
    KHAN, AJ
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 1994, 33 (01) : 81 - 84