Longterm interaction of the Wallstent with the coronary artery: serial intravascular ultrasound (IVUS) analysis using a motorized pullback system

被引:0
|
作者
Mudra, H [1 ]
Regar, E [1 ]
Kanig, A [1 ]
Henneke, KH [1 ]
Klauss, V [1 ]
Werner, F [1 ]
Rieber, J [1 ]
Theisen, K [1 ]
机构
[1] UNIV MUNICH,MUNICH,GERMANY
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:3267 / 3267
页数:1
相关论文
共 50 条
  • [1] Interaction of the Wallstent with the coronary artery during a longterm follow-up:: Morphological assessment by serial intravascular ultrasound with a motorized pullback system
    König, A
    Regar, E
    Henneke, KH
    Klauss, V
    Werner, F
    Rieber, J
    Metz, J
    Theisen, K
    Mudra, H
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 494A - 494A
  • [2] In vivo validation of intravascular ultrasound length measurements using a motorized transducer pullback system
    Fuessl, RT
    Mintz, GS
    Pichard, AD
    Kent, KM
    Satler, LF
    Popma, JJ
    Leon, MB
    AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (12): : 1115 - &
  • [3] Reproducibility of neointima quantification with motorized intravascular ultrasound pullback in stented coronary arteries
    Regar, E
    Werner, F
    Siebert, U
    Rieber, J
    Theisen, K
    Mudra, H
    Klauss, V
    AMERICAN HEART JOURNAL, 2000, 139 (04) : 632 - 637
  • [4] Serial intravascular ultrasound and quantitative coronary angiography after self-expandable Wallstent coronary artery implantation
    König, A
    Klauss, V
    Regar, E
    Rieber, J
    Casella, G
    Theisen, K
    Mudra, H
    AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (09): : 1015 - 1018
  • [5] Impact of Abnormal Glucose Tolerance on Progression of Coronary Artery Plaque Assessed by Serial Volumetric Intravascular Ultrasound (IVUS)
    Takashima, Hiroaki
    Mizuno, Tomofumi
    Asai, Kenji
    Kuroda, Yasuo
    Wakita, Yoshinori
    Kousaka, Takashi
    Kuhara, Yasushi
    Kurita, Akiyoshi
    Maeda, Kazuyuki
    Wakida, Yasushi
    Ito, Takayuki
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 59D - 59D
  • [6] The accuracy of length measurements using different intravascular ultrasound motorized transducer pullback systems
    Kaoru Tanaka
    Stéphane G. Carlier
    Gary S. Mintz
    Koichi Sano
    Xuebo Liu
    Kenichi Fujii
    Jose de Ribamar Costa
    Joanna Lui
    Jeffrey W. Moses
    Gregg W. Stone
    Martin B. Leon
    The International Journal of Cardiovascular Imaging, 2007, 23 : 733 - 738
  • [7] The accuracy of length measurements using different intravascular ultrasound motorized transducer pullback systems
    Tanaka, Kaoru
    Carlier, Stephane G.
    Mintz, Gary S.
    Sano, Koichi
    Liu, Xuebo
    Fujii, Kenichi
    de Ribamar Costa, Jose, Jr.
    Lui, Joanna
    Moses, Jeffrey W.
    Stone, Gregg W.
    Leon, Martin B.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2007, 23 (06): : 733 - 738
  • [8] Analysis of suboptimal stent deployment using intravascular ultrasound and coronary pressure pullback measurement
    Tanaka, Nobuhiro
    Pijls, Nico H. J.
    Yamashita, Jun
    Kimura, Yo
    Ogawa, Masashi
    Murata, Naotaka
    Sakoda, Kunihiro
    Hoshino, Kou
    Hokama, Youhei
    Yamashina, Akira
    JOURNAL OF CARDIOLOGY, 2017, 69 (3-4) : 613 - 618
  • [9] IVUS (Intravascular ultrasound) correlates with QCA (Quantitative coronary angiography) for the assessment of coronary artery disease at baseline, but not for serial changes across time
    Kalyanasundaram, A.
    Thornton, J.
    Wolski, K.
    Kapadia, S.
    Tuzcu, E. M.
    Nissen, S. E.
    Nicholls, S. J.
    EUROPEAN HEART JOURNAL, 2010, 31 : 792 - 792
  • [10] The accuracy of stent length measurements using different intravascular ultrasound motorized transducer pullback systems
    Tanaka, K
    Carlier, SG
    Mintz, GS
    Fujii, K
    Kimura, M
    Sano, K
    Costa, JD
    Lui, J
    Stone, GW
    Leon, MB
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (7A): : 198H - 198H