A Deep Siamese-Based Plantar Fasciitis Classification Method Using Shear Wave Elastography

被引:7
|
作者
Gao, Junling [1 ]
Xu, Lei [1 ,2 ]
Bouakaz, Ayache [3 ]
Wan, Mingxi [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Life Sci & Technol, Dept Biomed Engn, Xian 710049, Shaanxi, Peoples R China
[2] Xian Hosp Tradit Chinese Med, Xian 710021, Shaanxi, Peoples R China
[3] Univ Tours, INSERM, iBrain, UMR 1253, F-37032 Tours, France
基金
中国国家自然科学基金;
关键词
Plantar fasciitis; Siamese network; transfer learning; shear wave elastography; ULTRASOUND ELASTOGRAPHY; THYROID-NODULES; IMAGES; DIAGNOSIS;
D O I
10.1109/ACCESS.2019.2940645
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Two-dimensional shear wave elastography (2D-SWE) is an effective and feasible method for plantar fasciitis (PF) evaluation. Until now, only experienced doctors have been able to give relatively accurate evaluation via ultrasound images, resulting in low efficiency and high cost. Therefore, designing automatic algorithms to recognize the pattern of these ultrasound images is urgently required. In recent years, deep learning (DL) has made considerable progress in computer-aided diagnosis (CAD). However, there have been no studies that apply DL to the diagnosis of PF. To achieve robust PF classification, this paper builds a deep Siamese framework with multitask learning and transfer learning (DS-MLTL), which learns discriminative visual features and effective recognition functions using 2D-SWE. The DS-MLTL model comprises two VGG-style branches and a multitask loss including a classification loss and a Siamese loss. The Siamese loss leverages the intrinsic structure (similarities) of different images and contains a contrastive constraint and a similar constraint. In our framework, visual features and the multitask loss are learned jointly, and they can benefit from each other. To train the DS-MLTL model effectively, the model transfers knowledge from the large-scale ImageNet dataset to the PF classification task. For model evaluation, an SWE dataset of plantar fascia, which contains 282 images of a PF pattern and 60 images of a healthy pattern, is collected. Experimental results show that the DS-MLTL method achieves favorable accuracy of 85.09 +/- 6.67% and performs better than human-crafted features extracted from B-mode ultrasound and SWE. In addition, DS-MLTL also obtains the best performance compared with different DL models.
引用
收藏
页码:130999 / 131007
页数:9
相关论文
共 50 条
  • [1] Shear wave elastography for treatment monitoring of plantar fasciitis
    Gatz, Matthias
    Betsch, Marcel
    Quack, Valentin
    Bejder, Ljudmila
    Schrading, Simone
    Tingart, Markus
    Dirrichs, Timm
    [J]. JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2020, 60 (08): : 1137 - 1147
  • [2] Shear Wave Elastography (SWE) for the Evaluation of Patients with Plantar Fasciitis
    Gatz, Matthias
    Bejder, Ljudmila
    Quack, Valentin
    Schrading, Simone
    Dirrichs, Timm
    Tingart, Markus
    Kuhl, Christiane
    Betsch, Marcel
    [J]. ACADEMIC RADIOLOGY, 2020, 27 (03) : 363 - 370
  • [3] Statistical and Texture Descriptors of Symptomatic Plantar Fasciitis Using Ultrasound Shear Wave Elastography
    Zhang, Hongmei
    Xu, Lei
    Liu, Zhihui
    Lu, Shukuan
    Yin, Jichao
    Tian, Sibo
    Yang, Xiaofeng
    Wan, Mingxi
    [J]. IEEE ACCESS, 2020, 8 : 120146 - 120159
  • [4] Shear Wave Elastography of the Plantar Fascia: Comparison between Patients with Plantar Fasciitis and Healthy Control Subjects
    Baur, Daniel
    Schwabl, Christoph
    Kremser, Christian
    Taljanovic, Mihra S.
    Widmann, Gerlig
    Sconfienza, Luca Maria
    Sztankay, Judith
    Feuchtner, Gudrun
    Klauser, Andrea S.
    [J]. JOURNAL OF CLINICAL MEDICINE, 2021, 10 (11)
  • [5] Elasticity of the Achilles Tendon in Individuals With and Without Plantar Fasciitis: A Shear Wave Elastography Study
    Pan, Weiyi
    Zhou, Jiping
    Lin, Yuyi
    Zhang, Zhijie
    Wang, Yulong
    [J]. FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [6] Role of shear wave elastography in the diagnostic evaluation of plantar fasciitis: a prospective case–control study
    Harshith Yedahally Ramu
    Anuradha Sharma
    Nishith Kumar
    Ranjan Chandra
    Ranjan Kumar Wadhwa
    Dharmendra Kumar Singh
    [J]. Journal of Ultrasound, 2023, 26 : 385 - 391
  • [7] Deep learning based classification of breast tumors with shear-wave elastography
    Zhang, Qi
    Xiao, Yang
    Dai, Wei
    Suo, Jingfeng
    Wang, Congzhi
    Shi, Jun
    Zheng, Hairong
    [J]. ULTRASONICS, 2016, 72 : 150 - 157
  • [8] Biomechanical Effects of Plastic Heel Cup on Plantar Fasciitis Patients Evaluated by Ultrasound Shear Wave Elastography
    Lin, Che-Yu
    Chen, Pei-Yu
    Wu, Shin-Han
    Shau, Yio-Wha
    Wang, Chung-Li
    [J]. JOURNAL OF CLINICAL MEDICINE, 2022, 11 (08)
  • [9] Role of shear wave elastography in the diagnostic evaluation of plantar fasciitis: a prospective case-control study
    Ramu, Harshith Yedahally
    Sharma, Anuradha
    Kumar, Nishith
    Chandra, Ranjan
    Wadhwa, Ranjan Kumar
    Singh, Dharmendra Kumar
    [J]. JOURNAL OF ULTRASOUND, 2023, 26 (02) : 385 - 391
  • [10] Investigation of the acute plantar fasciitis with contrast-enhanced ultrasound and shear wave elastography - first results
    Putz, Franz Josef
    Hautmann, Matthias G.
    Banas, Miriam C.
    Jung, Ernst Michael
    [J]. CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2017, 67 (3-4) : 415 - 423