Benchmark solution for the prediction of temperature distributions during radiofrequency ablation of cardiac tissue

被引:2
|
作者
Roper, RT [1 ]
Jones, MR [1 ]
机构
[1] Brigham Young Univ, Dept Mech Engn, Provo, UT 84602 USA
关键词
D O I
10.1115/1.1785810
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Several studies on radiofrequency (RF) ablation are aimed at accurately predicting tissue temperature distributions by numerical solution of the bioheat equation. This paper describes the development of a solution that can serve as a benchmark for subsequent numerical solutions. The solution was obtained using integral transforms and evaluated using a C program. Temperature profiles were generated at various times and for different convection coefficients. In addition, a numerical model was developed using the same assumptions made in obtaining the benchmark solution. Comparison of surface and axial temperature profiles shows that the two solutions match very closely, cross validating the numerical methods used in evaluating both solutions.
引用
收藏
页码:519 / 522
页数:4
相关论文
共 50 条
  • [1] Analytical transient-time solution for temperature in non perfused tissue during radiofrequency ablation
    Lopez Molina, Juan A.
    Rivera, Maria J.
    Berjano, Enrique
    APPLIED MATHEMATICAL MODELLING, 2017, 42 : 618 - 635
  • [2] Tissue temperature controlled radiofrequency ablation
    Bierbaum, D
    Eick, O
    EUROPEAN HEART JOURNAL, 2002, 23 : 281 - 281
  • [3] Tissue temperature-controlled radiofrequency ablation
    Eick, OJ
    Bierbaum, D
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (03): : 725 - 730
  • [4] Temperature monitoring during radiofrequency ablation
    Dinerman, JL
    Berger, RD
    Calkins, H
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1996, 7 (02) : 163 - 173
  • [5] Temperature Simulation of an Ablation Needle for the Prediction of Tissue Necrosis during Liver Ablation
    Will, Maximilian
    Gerlach, Thomas
    Saalfeld, Sylvia
    Gutberlet, Marcel
    Duex, Daniel
    Schroeer, Simon
    Hille, Georg
    Wacker, Frank
    Hensen, Bennet
    Berg, Philipp
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (19)
  • [6] Spectral Changes Caused by Radiofrequency Ablation of Cardiac Tissue
    Aljishi, Mohammed
    Asfour, Huda
    Chahbazian, Tigran
    Muselimyan, Narine
    Swift, Luther
    Mercader, Marco
    Sarvazyan, Narine
    CIRCULATION RESEARCH, 2016, 119
  • [7] Noninvasive Assessment of Tissue Heating During Cardiac Radiofrequency Ablation Using MRI Thermography
    Kolandaivelu, Aravindan
    Zviman, Menekhem M.
    Castro, Valeria
    Lardo, Albert C.
    Berger, Ronald D.
    Halperin, Henry R.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2010, 3 (05): : 521 - U134
  • [8] Geometry and temperature distribution during radiofrequency tissue ablation:: An experimental ex vivo model
    Lobik, L
    Leveillee, RJ
    Hoey, MF
    JOURNAL OF ENDOUROLOGY, 2005, 19 (02) : 242 - 247
  • [9] ACCURACY OF A SINGLE TIP THERMISTOR IN THE MEASUREMENT OF THE PEAK TISSUE TEMPERATURE DURING RADIOFREQUENCY ABLATION
    HAINES, DE
    WHAYNE, JG
    CIRCULATION, 1993, 88 (04) : 400 - 400
  • [10] Microbubbles formation is related to increased tissue temperature during radiofrequency ablation of pulmonary veins
    Sarabanda, AV
    Milton, MA
    Johnson, SB
    Bunch, TJ
    Packer, DL
    CIRCULATION, 2003, 108 (17) : 542 - 542