Universal adhesive: the effect of different simulated pulpal pressure fluids and bonding modes to dentin

被引:7
|
作者
Goncalves, Lucelia Lemes [1 ]
Da Silva, Tania Mara [1 ]
Prakki, Anuradha [2 ]
Barcellos, Daphne Camara [3 ]
Caneppele, Taciana Marco Ferraz [4 ]
De Oliveira, Hueder Paulo Moises [5 ]
Goncalves, Sergio Eduardo de Paiva [4 ,6 ]
机构
[1] Anhanguera Fac Sao Jose Campos, Sao Jose Dos Campos, SP, Brazil
[2] Univ Toronto, Fac Dent, Dept Clin Sci Restorat, Toronto, ON, Canada
[3] Univ Fed Espirito Santo, Dept Prosthodont, Vitoria, ES, Brazil
[4] UNESP Univ Estadual Paulista, Inst Sci & Technol, Dept Restorat Dent, Sao Jose Dos Campos, SP, Brazil
[5] Fed Univ ABC, Ctr Nat & Human Sci, Santo Andre, SP, Brazil
[6] UNESP Univ Estadual Paulista, Inst Ciencia & Tecnol, Dept Odontol Restauradora, Campus Sao Jose Campos, BR-12245000 Sao Jose Dos Campos, SP, Brazil
关键词
Dental pulp; Dental bonding; Adhesives; SINGLE-STEP; PERMEABLE MEMBRANES; STRENGTH; ETCH; SYSTEMS; POLYMERIZATION; PENETRATION; DEGRADATION; TEMPERATURE; INTERFACE;
D O I
10.1007/s10266-021-00633-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to evaluate the effect of SPP with either fetal bovine serum (FBS) or deionized water (DW) on the bond strength (mu TBS) of a Universal adhesive to dentin, in both etch-and-rinse (ER) and self-etch (SE) modes. The kinematic viscosity (cSt) of FBS and DW was measured at 25 degrees C +/- 0.1 oC. Seventy-two sound human molars were sectioned and randomly divided into three groups according to the SPP conditions: (1) Control (0 cm H2O), (2) SPP (15 cm H2O) with FBS, (3) SPP (15 cm H2O) with DW. Each group was subdivided (n = 10) based on the bonding modes: ER (37% phosphoric acid + ScothBond Universal Adhesive) or SE (ScothBond Universal Adhesive). Samples were then submitted to mu TBS. Data were analyzed by Student's t test, two-way ANOVA and Tukey tests (p < 0.05). The cSt results showed that DW (23.59 +/- 0.39) had significantly higher values than FBS (22.33 +/- 0.06). With regard to SPP, the control group (36.1 MPa) had significantly higher values of mu TBS when compared to the SPP using FBS (31.06 MPa) and SPP with DW (26.55 MPa). According to ANOVA, the bonding modes and the interaction of simulated pulpal pressure (SPP) did not statistically influence the results (p < 0.05). The presence of SPP reduced the bond strength of Universal adhesive to dentin. DW during SPP had significantly reduced bonding values when compared to FBS. Bonding strategies were not affected by SPP when evaluated in a short period of time (24 h).
引用
收藏
页码:62 / 69
页数:8
相关论文
共 50 条
  • [1] Universal adhesive: the effect of different simulated pulpal pressure fluids and bonding modes to dentin
    Lucélia Lemes Gonçalves
    Tânia Mara Da Silva
    Anuradha Prakki
    Daphne Camara Barcellos
    Taciana Marco Ferraz Caneppele
    Hueder Paulo Moisés De Oliveira
    Sérgio Eduardo de Paiva Gonçalves
    Odontology, 2022, 110 : 62 - 69
  • [2] Effect of simulated pulpal pressure on self-adhesive cements bonding to dentin
    Mazzitelli, Claudia
    Monticelli, Francesca
    Osorio, Raquel
    Casucci, Alessio
    Toledano, Manuel
    Ferrari, Marco
    DENTAL MATERIALS, 2008, 24 (09) : 1156 - 1163
  • [3] Effect of Simulated Dental Pulpal Pressure Using Fetal Bovine Serum for the Bonding Performance of Contemporary Adhesive to Dentin
    Li, Yitong
    Maeno, Masahiko
    Cifuentes-Jimenez, Carolina Cecilia
    Komoto, Mei
    Liu, Yunqing
    Nara, Yoichiro
    Sano, Hidehiko
    Alvarez-Lloret, Pedro
    Yamauti, Monica
    Tomokiyo, Atsushi
    POLYMERS, 2024, 16 (09)
  • [4] Exposed Dentin: Influence of Cleaning Procedures and Simulated Pulpal Pressure on Bond Strength of a Universal Adhesive System
    Flury, Simon
    Peutzfeldt, Anne
    Schmidlin, Patrick R.
    Lussi, Adrian
    PLOS ONE, 2017, 12 (01):
  • [5] Effect of Er:YAG Laser on Dentin Bonding Durability Under Simulated Pulpal Pressure
    Bakry, Ahmed Samir
    Nakajima, Masatoshi
    Otsuki, Masayuki
    Tagami, Junji
    JOURNAL OF ADHESIVE DENTISTRY, 2009, 11 (05): : 361 - 368
  • [6] Degradation of Adhesive-Dentin Interfaces Created Using Different Bonding Strategies after Five-year Simulated Pulpal Pressure
    Feitosa, Victor P.
    Sauro, Salvatore
    Zenobi, Walter
    Silva, Julianne C.
    Abuna, Gabriel
    Van Meerbeek, Bart
    Sinhoreti, Mario A. C.
    Correr, Americo B.
    Yoshihara, Kumiko
    JOURNAL OF ADHESIVE DENTISTRY, 2019, 21 (03): : 199 - 207
  • [7] Effect of simulated pulpal pressure on dentin bond strength of self-etching bonding systems
    Moll, K
    Park, HJ
    Haller, B
    AMERICAN JOURNAL OF DENTISTRY, 2005, 18 (05): : 335 - 339
  • [8] The Effect of Different Condition of Pulpal Pressure on Microtensile Bond Strength of Several Dentin Bonding Agents on Deep and Superficial Dentin
    Montanari, Marco
    Fiorillo, Luca
    Cervino, Gabriele
    Sambataro, Sergio
    Herford, Alan Scott
    Cicciu, Marco
    MATERIALS, 2021, 14 (20)
  • [9] The effect of zoledronate-containing primer on dentin bonding of a universal adhesive
    Zenobi, Walter
    Feitosa, Victor Pinheiro
    Martins Moura, Maria Elisa
    D'arcangelo, Camillo
    de Azevedo Rodrigues, Lidiany Karla
    Sauro, Salvatore
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 77 : 199 - 204
  • [10] Bonding of chitosan and nanochitosan modified universal adhesive to dentin
    El-Din, Yasmin Ezz
    El-Banna, Ahmed
    Hussein, Tarek Salah
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2023, 125