Double plate osteosynthesis provides better biomechanical stabilization than double tension band technique in distal humerus fractures

被引:1
|
作者
Dogramaci, Yunus [1 ]
Esen, Erdinc [2 ]
Kurklu, Mustafa [3 ]
Kirici, Yalcin [4 ]
Atahan, Ali O. [5 ]
Komurcu, Mahmut [3 ]
机构
[1] Mustafa Kemal Univ, Tip Fak, Ortoped & Travmatol Anabilim Dali, TR-31100 Antakya, Hatay, Turkey
[2] Gazi Univ, Fac Med, Dept Orthoped & Traumatol, Ankara, Turkey
[3] Gulhane Mil Med Acad, Dept Orthoped, Ankara, Turkey
[4] Gulhane Mil Med Acad, Dept Anat, Ankara, Turkey
[5] Mustafa Kemal Univ, Dept Engn, TR-31100 Antakya, Hatay, Turkey
关键词
Biomechanics; distal humerus; fractures; osteosynthesis; SURGICAL-TREATMENT; INTRAARTICULAR FRACTURES; INTERNAL-FIXATION; INTERCONDYLAR FRACTURES; ELDERLY-PATIENTS; ADULTS;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: In this study we evaluated the stability and effectiveness of the double tension band osteosynthesis technique compared to the double plate osteosynthesis technique used for fixation of distal humerus fractures Materials and methods: The study was performed on two groups. and in each group eight cadaveric, elderly (mean age 70-80) human humeri was used An osteotomy was performed in the supracondylar region using a manual saw The first group (group 1) was fixed with double 3.5 mm reconstruction plates, while the second group (group 2) was fixed with the double tension band technique. using crossing Kirschner wires The osteotomy was designed so that the distal fragment would allow only a single screw per plate The constructs were evaluated using a material testing machine A linear non-cyclic load was applied until the failure of the constructs. The force which produced a 3 mm gap (3 mm gap strength). as detected visually with the aid of operating loupes. and the maximum load prior to failure of the fixation (maximum force) were measured from all tests Results: The mean value for the 3 mm gap strength was 1356 29 +/- 226 97 N for group 1 and 882 63 30521 N for group 2. The mean value of the maximum load strength was 1487.13 +/- 298 N for group 1 and 1232 10762 N for group 2 There were significant differences in 3 mm gap strengths of the two groups (p=0 005) There was also a significant difference in the maximum load between the two groups (p=0 016). Conclusion: Double plate osteosynthesis technique is superior to double tension band osteosynthesis for the fixation of distal humerus fractures.
引用
收藏
页码:44 / 49
页数:6
相关论文
共 50 条
  • [1] Double tension band osteosynthesis in transverse supracondylar distal humerus fractures and nonunions
    Allende, Christian
    Gutierrez, Natalia
    Savoy, Ignacio Fernandez
    Allende, Bartolome T.
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (12) : 2565 - 2569
  • [2] Double tension band osteosynthesis in transverse supracondylar distal humerus fractures and nonunions
    Christian Allende
    Natalia Gutierrez
    Ignacio Fernandez Savoy
    Bartolome T. Allende
    International Orthopaedics, 2012, 36 : 2565 - 2569
  • [3] Surgical treatment of comminuted intra-articular fractures of the distal humerus with double tension band osteosynthesis
    Zhao, J
    Wang, XW
    Zhang, QL
    ORTHOPEDICS, 2000, 23 (05) : 449 - 452
  • [4] The importance of interdigitating screw fixation of the trochlea in double plate osteosynthesis of low transcondylar distal humerus fractures: A biomechanical study
    Lappen, Sebastian
    Siebenlist, Sebastian
    Leschinger, Tim
    Kadantsev, Pavel
    Geyer, Stephanie
    Wegmann, Kilian
    Mueller, Lars-Peter
    Hackl, Michael
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (04):
  • [5] Angle-fixed plate fixation or double-plate osteosynthesis in fractures of the proximal humerus: a biomechanical study
    Hessmann, Martin H.
    Korner, Jan
    Hofmann, Alexander
    Sternstein, Werner
    Rommens, Pol M.
    BIOMEDIZINISCHE TECHNIK, 2008, 53 (03): : 130 - 137
  • [6] Biomechanical analysis of different osteosynthesis configurations in the pin and plate fixation method for distal humerus fractures
    Hakiminejad, Alireza
    Nourani, Amir
    Ghias, Narges
    Mahmoudi, Alireza
    Same, Kaveh
    Kamrani, Reza Shahriar
    Nabian, Mohammad Hossein
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [7] Biomechanical analysis of different osteosynthesis configurations in the pin and plate fixation method for distal humerus fractures
    Alireza Hakiminejad
    Amir Nourani
    Narges Ghias
    Alireza Mahmoudi
    Kaveh Same
    Reza Shahriar Kamrani
    Mohammad Hossein Nabian
    BMC Musculoskeletal Disorders, 24
  • [8] Double Tension Band Osteosynthesis in Inter-Condylar Humeral Fractures
    Munde, Santosh Lakshmanrao
    Bhatti, Mohd Javed
    Siwach, R. C.
    Gulia, Anil
    Kundu, Z. S.
    Bansal, Sanjeev
    Middha, Sanjay
    Kamra, Hemlata T.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2015, 9 (12) : RC08 - RC11
  • [9] Comparison of the Locking Intramedullary Nailing, Single Plate and Double Plate Osteosynthesis in Treatment of Humerus Shaft Fractures
    Tosun, Haci Bayram
    Serbest, Sancar
    Yasar, Mehmet Mete
    Uludag, Abuzer
    Ersoz, Galip
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2023, 33 (11): : 1315 - 1320
  • [10] Parallel versus orthogonal plate osteosynthesis of adult distal humerus fractures: a meta-analysis of biomechanical studies
    Chien-An Shih
    Wei-Ren Su
    Wei-Chin Lin
    Tai-Wei Tai
    International Orthopaedics, 2019, 43 : 449 - 460