The biomechanical and surgical solutions for patella implant in total knee arthroplasty

被引:1
|
作者
Mendes, DG [1 ]
Said, M [1 ]
Head, S [1 ]
Sabo, E [1 ]
Nachman, R [1 ]
Boss, JH [1 ]
机构
[1] Bnai Zion Med Ctr, Ctr Implant Surg, Haifa, Israel
关键词
total knee arthroplasty; patella; implant design; polyethylene wear; patello-femoral biomechanics; implant finite elements;
D O I
10.1615/CritRevBiomedEng.v28.i12.60
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A basic fault in designs of patella implants that calls for a prompt remedy is the inadequate polyethylene thickness in contact areas. The requirement for thickness of patella implants should be similar to the requirement set up by the FDA in 1993 regarding the tibial implants, that is, a minimal thickness of 8 mm. A solution is presented for the optimal design of the patella implant and for the appropriate surgical technique. The implant's undersurface that fixes to hone is concave and has a 1-cm wide but 5 to 6 mm short central peg that does not risk the integrity of the bone. Fixation of the concave aspect to the convex aspect of the bony patella strongly enhances resistance to medio-lateral and supero-inferior shear forces. The circumferential facet of the implant 8 mm thick assures uniform thickness of the entire implant and assures optimal mechanical properties of the polyethylene. The articulating surface is tailored to conform to the corresponding femoral trochlear groove and condyles. It can be made to fit any femoral component of any knee implant.
引用
收藏
页码:23 / 32
页数:10
相关论文
共 50 条
  • [1] Biomechanical and surgical solutions for patella implant in total knee arthroplasty
    Mendes, David G.
    Said, Mazen
    Head, Sorin
    Sabo, Edmond
    Nachman, Ricardo
    Boss, Jochanan H.
    Critical Reviews in Biomedical Engineering, 2000, 28 (01) : 23 - 32
  • [2] Biomechanical and surgical solutions for patella implant in total knee arthroplasty
    Mendes, David G.
    Said, Mazen
    Head, Sorin
    Sabo, Edmond
    Nachman, Ricardo
    Boss, Jochanan H.
    Critical Reviews in Biomedical Engineering, 1998, 26 (05):
  • [3] Biomechanical and surgical solutions for patellar implant in total knee arthroplasty
    Mendes, DG
    Said, M
    Head, S
    Sabo, E
    Nachman, R
    Boss, JH
    ORTHOPEDICS, 1999, 22 (10) : 949 - 951
  • [4] Clinical and biomechanical assessment of patella resurfacing in total knee arthroplasty
    Berti, Lisa
    Benedetti, Maria Grazia
    Ensini, Andrea
    Catani, Fabio
    Giannini, Sandro
    CLINICAL BIOMECHANICS, 2006, 21 (06) : 610 - 616
  • [5] Patella in total knee arthroplasty
    Barrack, RL
    Burak, C
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (389) : 62 - 73
  • [6] THE PATELLA IN TOTAL KNEE ARTHROPLASTY
    CAMERON, HU
    FEDORKOW, DM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1982, (165) : 197 - 199
  • [7] THE PATELLA IN TOTAL KNEE ARTHROPLASTY
    VINCE, KG
    MCPHERSON, EJ
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 1992, 23 (04) : 675 - 686
  • [8] Patella or not? (Is the patella component the 'Cinderella' of total knee arthroplasty?)
    Mendes, DG
    Fraenkel, P
    KNEE, 2000, 7 (04): : 205 - 206
  • [9] The patella in total knee arthroplasty: resurfacing or nonresurfacing of patella
    Anders Lindstrand
    Otto Robertsson
    Stefan Lewold
    Sören Toksvig-Larsen
    Knee Surgery, Sports Traumatology, Arthroscopy, 2001, 9 : S21 - S23
  • [10] The patella in total knee arthroplasty: resurfacing or nonresurfacing of patella
    Lindstrand, A
    Robertsson, O
    Lewold, S
    Toksvig-Larsen, S
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2001, 9 (Suppl 1) : S21 - S23