Loading Margin Improvement through Adjustement of the Wind Farms Power Factor

被引:0
|
作者
Neumann, Victor [1 ]
Kuiava, Roman [2 ]
Ramos, Rodrigo A. [3 ]
Pavani, Ahda [4 ]
Alburguetti, Livia [4 ]
机构
[1] Univ Fed Parana, Dept Engn, BR-85950000 Palotina, PR, Brazil
[2] Univ Fed Parana, Dept Elect Engn, BR-81531980 Curitiba, Parana, Brazil
[3] Univ Sao Paulo, Dept Elect Engn, Engn Sch Sao Carlos, BR-13566590 Sao Carlos, SP, Brazil
[4] Fed Univ ABC, Ctr Engn & Appl Social Sci, BR-09210580 Santo Andre, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Sensitivity; Loading margin; Voltage stability; Voltage preventive control; Wind farm;
D O I
10.1109/PESGM46819.2021.9638214
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper proposes a voltage preventive control strategy as an activity to support the operation programming of the power system. This strategy is based on the maximization of the loading margin by optimizing the power factor adjustment of wind farms that most significantly impact this stability margin. The power system used to test this proposal is a 56-bus system prepared with actual data from the Northeast (NE) subsystem of Brazilian Interconnected Power System (BIPS), which includes 22 wind farms. This system was used in several simulations to validate the proposed strategy, which presented satisfactory results.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Online Decision Tree based strategy for power system static security margin improvement using wind farms
    Gholami, M.
    Gharehpetian, G. B.
    Mohammadi, M.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 83 : 15 - 20
  • [2] Loading Margin Sensitivity in Relation to the Wind Farm Generation Power Factor for Voltage Preventive Control
    Victor R. Neumann Silva
    Roman Kuiava
    [J]. Journal of Control, Automation and Electrical Systems, 2019, 30 : 1041 - 1050
  • [3] Loading Margin Sensitivity in Relation to the Wind Farm Generation Power Factor for Voltage Preventive Control
    Neumann Silva, Victor R.
    Kuiava, Roman
    [J]. JOURNAL OF CONTROL AUTOMATION AND ELECTRICAL SYSTEMS, 2019, 30 (06) : 1041 - 1050
  • [4] The loading of wind turbines in wind farms
    Quarton, DC
    [J]. WIND ENERGY CONVERSION 1996, 1997, : 443 - 448
  • [5] Probabilistic assessment of oscillatory stability margin of power systems incorporating wind farms
    Li, Gengyin
    Yue, Hao
    Zhou, Ming
    Wei, Junqiang
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 58 : 47 - 56
  • [6] Assessment of wind power predictability as a decision factor in the investment phase of wind farms
    Girard, R.
    Laquaine, K.
    Kariniotakis, G.
    [J]. APPLIED ENERGY, 2013, 101 : 609 - 617
  • [8] Power quality and dynamic performance improvement of wind farms using a STATCOM
    Qiao, Wei
    Harley, Ronald G.
    [J]. 2007 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, 2007, : 1832 - 1838
  • [9] Effect of wind-turbine surface loading on power resources in LES of large wind farms
    Meyers, Johan
    Meneveau, Charles
    [J]. DIRECT AND LARGE-EDDY SIMULATION VIII, 2011, 15 : 425 - +
  • [10] Power Quality Improvement of Grid Connected Wind Farms through Voltage Restoration Using Dynamic Voltage Restorer
    Jerin, Rini Ann A.
    Palanisamy, K.
    Umashankar, S.
    Thirumoorthy, A. D.
    [J]. INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2016, 6 (01): : 53 - 60