Diagnostic effect of complete histologic sampling of prostate needle biopsy specimens

被引:0
|
作者
Reyes, AO [1 ]
Humphrey, PA [1 ]
机构
[1] Washington Univ, Med Ctr, Lauren V Ackerman Lab Surg Pathol, Div Surg Pathol,Dept Pathol,Barnes Jewish Hosp, St Louis, MO 63110 USA
关键词
prostate; cancer; sampling; prostatic intraepithelial neoplasia [PIN; atypia;
D O I
暂无
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
In 1997, approximately 1 million 18-gauge prostate needle core biopsies were performed in the United States. Yet limited data exist on the effect of histologic sampling on detection of carcinoma in needle biopsy tissue, and no data have been published on the diagnostic yield of complete histopathologic examination of prostate needle biopsy specimens. We sought to evaluate the diagnostic effect of obtaining additional sections after a nonmalignant diagnosis was given on three initial slides. This prospective study was of 200 consecutively identified cases. Complete histologic examination of all needle biopsy tissue from 100 cases diagnosed as atypia (encompassing high-grade prostatic intraepithelial neoplasia [PIN] and focal glandular atypia) on the initial three slides was compared with complete examination for a control population of 100 cases diagnosed as benign prostatic tissue on the initial three slides. New histologic abnormalities in levels were characterized as to diagnostic category, distribution in additional slides and morphometrically determined size. Complete histologic sampling of prostate needle biopsy specimens with serial sections entirely through the paraffin block required a mean of 30 slides per block, with a mean of 4 sections per slide. In 17 (17%) cases with atypia diagnosed on the initial three slides, a new histologic abnormality was detected in levels. In 4 (10%) of 40 cases of focal glandular atypia, definitive carcinoma was present on additional sections, including the first additional slide. In no case with a diagnosis of benign prostatic tissue (n = 100) or high-grade PIN (n = 60) on the three initial slides was carcinoma diagnosed on additional slides. Additional histologic sampling after a diagnosis of isolated high-grade FIN does not seem necessary; these patients with high-grade PIN should undergo rebiopsy. Because of the profound consequences of a definitive diagnosis of prostatic carcinoma, we recommend obtaining a single additional slide with several 3-mu m sections after a diagnosis of focal glandular atypia has been given for three initial slides of needle biopsy specimens from the prostate.
引用
收藏
页码:416 / 422
页数:7
相关论文
共 50 条
  • [1] Real value of complete histologic sampling of prostate needle biopsy specimens
    Pardo, F. J.
    Panizo, A.
    Queipo, F.
    Martinez Penuela, A.
    Carias, R.
    Laviano, T.
    Sola, J. J.
    VIRCHOWS ARCHIV, 2011, 459 : S290 - S290
  • [2] Diagnostic effect of complete histologic sampling of prostate needle biopsies
    Reyes, AO
    Humphrey, PA
    LABORATORY INVESTIGATION, 1997, 76 (01) : 496 - 496
  • [3] How often are diagnostic features missed with less extensive histologic sampling of prostate needle biopsy specimens?
    Brat, DJ
    Wills, ML
    Lecksell, KL
    Epstein, JI
    AMERICAN JOURNAL OF SURGICAL PATHOLOGY, 1999, 23 (03) : 257 - 262
  • [4] Diagnostic effect of an improved preembedding method of prostate needle biopsy specimens
    Rogatsch, H
    Moser, P
    Volgger, H
    Horninger, W
    Bartsch, G
    Mikuz, G
    Mairinger, T
    HUMAN PATHOLOGY, 2000, 31 (09) : 1102 - 1107
  • [5] ADENOSIS OF THE PROSTATE - HISTOLOGIC FEATURES IN NEEDLE-BIOPSY SPECIMENS
    GAUDIN, PB
    EPSTEIN, JI
    AMERICAN JOURNAL OF SURGICAL PATHOLOGY, 1995, 19 (07) : 737 - 747
  • [6] Diagnostic accuracy of prostate needle biopsy
    Donahue T.
    Moul J.
    Current Urology Reports, 2002, 3 (3) : 215 - 221
  • [7] BIOPSY NEEDLE FOR SAMPLING OF SKELETAL-MUSCLE SPECIMENS
    MULLERWENING, D
    HOFFMANN, G
    RESEARCH IN EXPERIMENTAL MEDICINE, 1972, 157 (01) : 83 - +
  • [8] The diagnostic quality of needle brain biopsy specimens obtained with different sampling methods – Experimental study
    Piotr Trojanowski
    Bożena Jarosz
    Dariusz Szczepanek
    Scientific Reports, 9
  • [9] Infarct of the prostate gland - Experience on needle biopsy specimens
    Milord, RA
    Kahane, H
    Epstein, JI
    AMERICAN JOURNAL OF SURGICAL PATHOLOGY, 2000, 24 (10) : 1378 - 1384
  • [10] Optimizaton of Fixation and Processing of Biopsy Gun Prostate Needle Biopsy Specimens
    Zarbo, R. J.
    Gupta, N.
    Varney, R.
    Main, N.
    Richard, S.
    Mahar, B.
    Kryvenko, O. N.
    McMahon, S.
    Draga, N.
    Alassi, O.
    Ormsby, A.
    D'Angelo, R.
    LABORATORY INVESTIGATION, 2011, 91 : 457A - 458A