TLC-smartphone in antibiotics determination and low-quality pharmaceuticals detection

被引:20
|
作者
Gad, Asmaa G. [1 ]
Fayez, Yasmin Mohammed [2 ]
Kelani, Khadiga M. [1 ,2 ]
Mahmoud, Amr M. [2 ]
机构
[1] Modern Univ Technol & Informat, Fac Pharm, Analyt Chem Dept, Cairo, Egypt
[2] Cairo Univ, Fac Pharm, Analyt Chem Dept, El Kasr El Aini St, Cairo 11562, Egypt
关键词
ORNIDAZOLE; OFLOXACIN; DRUGS; HPLC;
D O I
10.1039/d1ra01346g
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Thin layer chromatography (TLC) is a powerful and simple technique for screening and quantifying low quality and counterfeit pharmaceutical products. The detection methods used to detect and quantify separate analytes in TLC ranges from the densitometric method to mass spectrometric or Raman spectroscopic methods. This work describes the development and optimization of a simple and sensitive TLC method utilizing a smartphone CCD camera for verification of both identity and quantity of antibiotics in dosage form, namely ofloxacin and ornidazole. Mixtures of ofloxacin and ornidazole were chromatographed on a silica gel 60 F-254 plate as a stationary phase. The optimized mobile phase is n-butanol : methanol : ammonia (8 : 1 : 1.5 by volume). Iodine vapor has been used as a "universal stain" to visualize the spots on the TLC plates in order to obtain a visual image using the smartphone camera and a desk lamp as an illumination source, thus eliminating the need for a UV illumination source. The recorded images were processed to calculate the R-f values (R-f values for ofloxacin and ornidazole were 0.12 and 0.76, respectively) which provide identity of the drugs while spot intensity was calculated using a commercially available smartphone app and employed for quantitative analysis of the antibiotics and "acetaminophen" as an example of a counterfeit substance. The smartphone TLC method yielded a linearity of ofloxacin and ornidazole in the range of 12.5-62.5 mu g/band and 500-1000 mu g/band, respectively. The limit of detection was found to be 1.6 mu g/spot for ofloxacin and 97.8 mu g/spot for ornidazole. The proposed method was compared with the bench top densitometric method for verification using a Camag TLC Scanner 3, the spot areas were scanned at 320 nm. The R-f value of ofloxacin and ornidazole was calculated to be 0.12 and 0.76, respectively. The densitometric method yielded a linearity of ofloxacin and ornidazole in the range of 5-40 mu g/band and 5-50 mu g/band, respectively. The limit of detection was found to be 0.8 mu g/spot for ofloxacin and 1.1 mu g/spot for ornidazole. The proposed method has been successfully applied for the determination of ofloxacin and ornidazole present in more than one pharmaceutical dosage form and was comparable to the densitometric method.
引用
收藏
页码:19196 / 19202
页数:7
相关论文
共 50 条
  • [1] Paper analytical devices for detection of low-quality pharmaceuticals
    Weaver, A.
    Lieberman, M.
    MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS XII, 2014, 8976
  • [2] Screening for Refractive Error with Low-Quality Smartphone Images
    Yang, Zhongqi
    Fu, Eugene Yujun
    Ngai, Grace
    Leong, Hong Va
    Do, Chi-wai
    Chan, Lily
    MOMM 2020: THE 18TH INTERNATIONAL CONFERENCE ON ADVANCES IN MOBILE COMPUTING & MULTIMEDIA, 2020, : 119 - 128
  • [3] Gesture detection in low-quality video
    Roh, Myung-Cheol
    Lee, Seong-Whan
    18TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOL 4, PROCEEDINGS, 2006, : 791 - +
  • [4] Object Detection on Underground Low-quality Images
    Mu, Qi
    He, Zhiqiang
    Liu, Yankui
    Sun, Yu
    2018 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS AND CONTROL ENGINEERING (ISPECE 2018), 2019, 1187
  • [5] Survey of Face Detection on Low-quality Images
    Zhou, Yuqian
    Liu, Ding
    Huang, Thomas
    PROCEEDINGS 2018 13TH IEEE INTERNATIONAL CONFERENCE ON AUTOMATIC FACE & GESTURE RECOGNITION (FG 2018), 2018, : 769 - 773
  • [6] Low-Quality Deepfake Detection via Unseen Artifacts
    Chhabra S.
    Thakral K.
    Mittal S.
    Vatsa M.
    Singh R.
    IEEE Transactions on Artificial Intelligence, 2024, 5 (04): : 1573 - 1585
  • [7] Detection and Mosaicing Techniques for Low-Quality Retinal Videos
    Camara, Jose
    Silva, Bruno
    Gouveia, Antonio
    Pires, Ivan Miguel
    Coelho, Paulo
    Cunha, Antonio
    SENSORS, 2022, 22 (05)
  • [8] Low-Quality Error Detection for Noisy Knowledge Graphs
    Bu, Chenyang
    Yu, Xingchen
    Hong, Yan
    Jiang, Tingting
    JOURNAL OF DATABASE MANAGEMENT, 2021, 32 (04) : 48 - 64
  • [9] Early Detection of Myocardial Infarction in Low-Quality Echocardiography
    Degerli, Aysen
    Zabihi, Morteza
    Kiranyaz, Serkan
    Hamid, Tahir
    Mazhar, Rashid
    Hamila, Ridha
    Gabbouj, Moncef
    IEEE ACCESS, 2021, 9 : 34442 - 34453
  • [10] Employing Super Resolution to Improve Low-Quality Deepfake Detection
    Perera, Anjana Samindra
    Atukorale, Ajantha S.
    Kumarasinghe, Prabhash
    2022 22ND INTERNATIONAL CONFERENCE ON ADVANCES IN ICT FOR EMERGING REGIONS (ICTER), 2022,