Revised Evaluation of Hemodilution Response in the Semi-Closed Loop Infusion System

被引:1
|
作者
Markevicius, Vytautas [1 ]
Cincikas, Darius [2 ]
Porvaneckas, Narunas [3 ]
Stankevicius, Edgaras [4 ]
Navikas, Dangirutis [1 ]
Andriukaitis, Darius [1 ]
Sipylaite, Jurate [2 ]
Svediene, Saule [2 ]
Uvarovas, Valentinas [3 ]
Satkauskas, Igoris [2 ]
Kvederas, Giedrius [3 ]
Valinevicius, Algimantas [1 ]
Zilys, Mindaugas [1 ]
Andrijauskas, Audrius [2 ]
机构
[1] Kaunas Univ Technol, Dept Elect Engn, Studentu St 50-418, LT-51368 Kaunas, Lithuania
[2] Vilnius State Univ, Fac Med, Clin Anaesthesiol & Intens Care, Siltnamiu St 29, LT-04130 Vilnius, Lithuania
[3] Vilnius State Univ, Fac Med, Clin Rheumatol Orthopaed Traumatol & Reconstruct, Siltnamiu St 29, LT-04130 Vilnius, Lithuania
[4] Lithuanian Univ Hlth Sci, Inst Physiol & Pharmacol, A Mickeviciaus St 9, LT-44307 Kaunas, Lithuania
关键词
ACDSS; SCLIS; mVLT; hemoglobin; fluids; PULSE PRESSURE VARIATIONS; FLUID RESPONSIVENESS; ZONE APPROACH; GREY ZONE; TESTS;
D O I
10.5755/j01.eee.22.1.12826
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A mini volume loading test (mVLT) method is used for decision making in our prototype semi-closed loop infusion system (SCLIS). The mVLT fluid protocol consists of hemodilution response-guided mini fluid challenges. Each mini fluid challenge (MFC) consists of a 2.5 ml kg(-1)-5 ml kg(-1) crystalloid bolus infused over 2 min-5 min and followed by a 5 min period with no fluids. Arterial plasma dilution efficacy (aPDE) of a MFC is calculated from invasively measured hemoglobin (aHb) before and after each MFC. Capillary plasma dilution efficacy (cPDE) is calculated from non-invasively measured hemoglobin (SpHb). The zero or negative arterio-capillary plasmadilution efficacy difference (acPED <= 0 p.d.u.) is an indication of hemodilution non-response and imminent edema. However, it requires both invasive and non-invasive hemoglobin measurements. A non-invasive assessment of hemodilution response within the mVLT method would increase its practical application and reduce costs further enhancing its applicability in the SCLIS. This possibility exists if the cPDE could reliably predict the acPED value or the hemodilution response (the presence of acPED within a range of > 0) or non-response (acPED <= 0). We report a retrospective observational study in an elective total knee arthoplasty (TKA) setting. The 2.5 ml kg(-1) boluses were used in six MFCs in both pre-and post-operative mVLT sessions. The primary objective was to assess the accuracy of cPDE in predicting the hemodilution response using the receiver operating characteristic (ROC) curve and gray zone approaches. Our secondary objective was to investigate the feasibility of a statistical optimization method (SOM) in predicting the acPED. The analysis included 480 paired values of cPDE and acPED. The best cut-off value for cPDE was 0.015 p.d.u. (specificity = 0.84, sensitivity = 0.90). The gray zone identified a range of cPDE values between 0.013 and 0.028 (p.d.u.) for which the hemodilution response could not be indicated reliably. The 14 % of the cPDE values were in this range. The non-invasive evaluation of hemodilution response is acceptably accurate in the perioperative TKA setting. The mVLT algorithm within our prototype SCLIS was upgraded by implementing the results of the present study.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 50 条
  • [1] In Silico Testing of the Semi-Closed Loop Infusion System with a New Simulator
    Markevicius, V.
    Andrijauskas, A.
    Navikas, D.
    Dubauskiene, N.
    Porvaneckas, N.
    Stankevicius, E.
    Uvarovas, V.
    Gelzinis, G.
    Cepenas, M.
    Andriukaitis, D.
    Malekian, R.
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2014, 20 (09) : 19 - 24
  • [2] In Vivo Testing of the Semi-Closed Loop Infusion System: the Preliminary Observations
    Andrijauskas, Audrius
    Markevicius, Vytautas
    Navikas, Dangirutis
    Porvaneckas, Narunas
    Andriukaitis, Darius
    Stankevicius, Edgaras
    Uvarovas, Valentinas
    Sipylaite, Jurate
    Kvederas, Giedrius
    Gelzinis, Giedrius
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2015, 21 (01) : 28 - 32
  • [3] A SEMI-CLOSED LOOP COMPUTER-ASSISTED INSULIN INFUSION SYSTEM - HOSPITAL USE FOR CONTROL OF DIABETES IN PATIENTS
    CHISHOLM, DJ
    KRAEGEN, EW
    BELL, DJ
    CHIPPS, DR
    MEDICAL JOURNAL OF AUSTRALIA, 1984, 141 (12-1) : 784 - 789
  • [4] Climatic Evaluation of Semi-Closed Greenhouses
    Campen, J. B.
    Kempkes, F. L. K.
    INTERNATIONAL SYMPOSIUM ON HIGH TECHNOLOGY FOR GREENHOUSE SYSTEMS: GREENSYS2009, 2011, (893): : 495 - 501
  • [5] AN IMPROVED SEMI-CLOSED ANESTHESIA SYSTEM
    RUBEN, H
    GABRIELSEN, J
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1981, 25 : 87 - 87
  • [6] A trip time model for traffic flow on a semi-closed loop
    McCartney, Mark
    MATHEMATICAL AND COMPUTER MODELLING, 2010, 52 (5-6) : 902 - 917
  • [7] Cost and energy savings on closed and semi-closed loop mine surface cooling systems
    Moropa, Thabiso S.
    Marais, Johan H.
    Schutte, Abraham J.
    2017 INTERNATIONAL CONFERENCE ON THE INDUSTRIAL AND COMMERCIAL USE OF ENERGY (ICUE), 2017,
  • [8] CONTAMINATION OF OPERATING ROOM BY SEMI-CLOSED ANESTHESIA SYSTEM
    COLE, F
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1967, 202 (03): : 245 - &
  • [9] Backlash Compensation on CNC Machine tool Based on Semi-closed Loop Control
    Feng, Bin
    Mei, Xuesong
    Guo, Liang
    Zhang, Dongsheng
    Cheng, Youlong
    SUSTAINABLE CONSTRUCTION MATERIALS AND COMPUTER ENGINEERING, 2012, 346 : 644 - 649
  • [10] Semi-Closed Loop Control of NC Machine Tools Based on the Displacement Error
    Gao, Ji
    Zhao, Qiang
    Xia, Tian
    ADVANCES IN ENGINEERING DESIGN AND OPTIMIZATION, PTS 1 AND 2, 2011, 37-38 : 1138 - 1141