Influence of Magnetic Fields on Inrush Current Prestrike Arc Behaviors of Vacuum Interrupters

被引:0
|
作者
Yu, Yongxiang [1 ]
Liu, Zhiyuan [1 ]
Geng, Yun [1 ]
Geng, Yingsan [1 ]
Wang, Jianhua [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the case of back-to-back capacitor banks switching, the inrush current arcs can locally melt the contact surfaces of interrupters during prestrike processes. The magnetic field of the contact would influence the behaviors of the inrush current prestrike arcs. The objective of this paper is to determine the influences of cup-type transverse magnetic field (TMF) and cup-type axial magnetic field (AMF) contacts on prestrike arc behaviors of vacuum interrupters (VIs) during capacitive making processes. The inrush current arc behaviors were observed by a high-speed camera. The contact diameter of the VIs was 48 mm. The insulating envelope of the VIs was transparent and there was no metal vapor shield inside the VIs for observation of prestrike arcs. Two types of cup-type vacuum interrupter contacts with different magnetic field structures (TMF and AMF) were used. The prestrike arc observations indicate that the cup-type AMF contacts are superior than the cup-type TMF contacts because of less damages of the prestrike arcs to the contact surfaces.
引用
收藏
页码:223 / 226
页数:4
相关论文
共 50 条
  • [1] Influence of Contact Plate Slots on Inrush Current Prestrike Arc Behaviors of Vacuum Interrupters
    Yu, Yongxiang
    Li, Guoqin
    Geng, Yingsan
    Liu, Zhiyuan
    Wang, Jianhua
    2017 4TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT-SWITCHING TECHNOLOGY (ICEPE-ST), 2017, : 161 - 164
  • [2] Prestrike Inrush Current Arc Behaviors in Vacuum Interrupters Subjected to a Transverse Magnetic Field and an Axial Magnetic Field
    Yu, Yongxiang
    Li, Guoqin
    Geng, Yingsan
    Wang, Jianhua
    Liu, Zhiyuan
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2018, 46 (08) : 3075 - 3082
  • [3] Prestrike inrush current arc behavior in AMF vacuum interrupters subjected to contact plate slots
    Yu, Yongxiang
    Yao, Daojin
    Shi, Jie
    Zhou, Wei
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 201
  • [4] Kinetic Model of Prestrike Arc in Vacuum Interrupters
    Zhou, Zhipeng
    Wang, Zhenxing
    Tian, Yunbo
    Geng, Yingsan
    Liu, Zhiyuan
    2015 3RD INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT - SWITCHING TECHNOLOGY (ICEPE-ST), 2015, : 290 - 293
  • [5] Inrush Current Arc Characteristics In Vacuum Interrupters With Axial Magnetic Field Contact And Butt-Type Contact
    Geng, Yun
    Yu, Yongxiang
    Geng, Yingsan
    Wang, Jianhua
    Liu, Zhiyuan
    2015 3RD INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT - SWITCHING TECHNOLOGY (ICEPE-ST), 2015, : 512 - 515
  • [6] Capacitive Current Switching of Vacuum Interrupters and Inrush Currents
    Yang, He
    Geng, Yingsan
    Liu, Zhiyuan
    25TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2012), 2012, : 228 - 231
  • [7] POST ARC CURRENT OF VACUUM INTERRUPTERS
    YANABU, S
    HOMMA, M
    KANEKO, E
    TAMAGAWA, T
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (01): : 166 - 172
  • [8] POST ARC CURRENT IN VACUUM INTERRUPTERS
    YANABU, S
    SATOH, Y
    HONMA, M
    TAMAGAWA, T
    KANEKO, E
    IEEE TRANSACTIONS ON POWER DELIVERY, 1986, 1 (04) : 209 - 214
  • [9] Current constriction of high-current vacuum arc in vacuum interrupters
    Wang, Lijun
    Jia, Shenli
    Zhang, Ling
    Yang, Dingge
    Shi, Zongqian
    Gentils, Francois
    Jusselin, Benoit
    JOURNAL OF APPLIED PHYSICS, 2008, 103 (06)
  • [10] POST ARC CURRENT IN VACUUM INTERRUPTERS.
    Yanabu, S.
    Satoh, Y.
    Honma, M.
    Tamagawa, T.
    Kaneko, E.
    1600, (PWRD-1):