Development and Validation of a Magnetic Resonance Index for Assessing Fistulas in Patients With Crohn's Disease

被引:60
|
作者
Hindryckx, Pieter [1 ,2 ]
Jairath, Vipul [1 ,3 ,4 ]
Zou, Guangyong [1 ,4 ]
Feagan, Brian G. [1 ,3 ,4 ]
Sandborn, William J. [1 ,5 ]
Stoker, Jaap [6 ]
Khanna, Reena [1 ,3 ]
Stitt, Larry [1 ,4 ]
van Viegen, Tanja [1 ]
Shackelton, Lisa M. [1 ]
Taylor, Stuart A. [7 ]
Santillan, Cynthia [8 ]
Mearadji, Banafsche [6 ]
D'Haens, Geert [1 ,9 ]
Richard, Marie-Paule [10 ]
Panes, Julian [11 ]
Rimola, Jordi [12 ]
机构
[1] Robarts Clin Trials Inc, London, ON, Canada
[2] Univ Ghent, Dept Gastroenterol, Ghent, Belgium
[3] Univ Western Ontario, Div Gastroenterol, Dept Med, 1151 Richmond St, London, ON N6A 5B6, Canada
[4] Univ Western Ontario, Dept Epidemiol & Biostat, London, ON, Canada
[5] Univ Calif San Diego, Div Gastroenterol, La Jolla, CA 92093 USA
[6] Univ Amsterdam, Acad Med Ctr, Dept Radiol & Nucl Med, Amsterdam, Netherlands
[7] UCL, Ctr Med Imaging, London, England
[8] Univ Calif San Diego, Dept Radiol, La Jolla, CA 92093 USA
[9] Acad Med Ctr, Ctr Inflammatory Bowel Dis, Amsterdam, Netherlands
[10] Tigenix SAU, Madrid, Spain
[11] Hosp Clin Barcelona, Dept Gastroenterol, August Pi & Sunyer Biomed Res Inst, Biomed Res Networking Ctr Hepat & Digest Dis, Barcelona, Spain
[12] Hosp Clin Barcelona, Dept Radiol, Barcelona, Spain
关键词
ICCs; VAS; healing; remission; QUALITY-OF-LIFE; AREAS; MRI;
D O I
10.1053/j.gastro.2019.07.027
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND & AIMS: There is no validated magnetic resonance imaging (MRI) index for assessment of perianal fistulas in patients with Crohn's disease (CD). We developed and internally validated a new instrument. METHODS: We used paired baseline and week-24 MRI scans from 160 participants in a randomized placebo-controlled trial of stem cell therapy for patients with perianal fistulizing CD. Four radiologists scored disease activity using index items identified during previous studies and exploratory items. Reliability was assessed using intraclass correlation coefficients. We developed an index using backward elimination linear regression analysis, in which potential independent variables were items having intraclass correlation coefficients of at least 0.4 and the dependent variable was perianal fistulizing disease activity, measured on a 100-mm visual analogue scale. The final model was internally validated using the .632 bootstrap method to correct model optimism and quantify calibration accuracy. We evaluated responsiveness of the index by assessing longitudinal validity and estimating standardized effect sizes. RESULTS: We developed the magnetic resonance novel index for fistula imaging in CD (MAGNIFI-CD) using 6 items. The optimism-corrected R-2 of the model was 0.71, which was comparable to R-2 for the original sample (0.74). The calibration slope for the model was 0.98. Compared with the original and modified versions of the Van Assche Index, the MAGNIFI-CD had improved operating characteristics. Estimates of intraclass correlation coefficients for MAGNIFI-CD, the modified Van Assche Index, and Van Assche Index were 0.85 (95% confidence interval [CI], 0.77-0.90), 0.81 (95% CI, 0.74-0.86), and 0.81 (95% CI, 0.71-0.86) for intra-rater reliability, and 0.74 (95% CI, 0.63-0.80), 0.67 (95% CI, 0.55-0.75) and 0.68 (95% CI, 0.56-0.77) for inter-rater reliability. Corresponding standardized effect size estimates were 1.02 (95% CI, 0.65-1.39), 0.84 (95% CI, 0.48-1.21), and 0.68 (95% CI, 0.33-1.03). CONCLUSIONS: We developed an index called the MAGNIFI-CD, which is based on 6 items. It assesses MRI data and determines perianal fistulizing CD activity with improved operating characteristics compared to previous indices. This index may be used as an outcome measure in clinical trials comparing treatment effects in patients with perianal fistulizing CD. Although the performance of the MAGNIFI-CD indicates its stability and reasonable external validity, external validation is needed.
引用
收藏
页码:1233 / +
页数:17
相关论文
共 50 条
  • [1] Development and Validation of a Simplified Magnetic Resonance Index of Activity for Crohn's Disease
    Ordas, Ingrid
    Rimola, Jordi
    Alfaro, Ignacio
    Rodriguez, Sonia
    Castro-Poceiro, Jesus
    Ramirez-Morros, Anna
    Gallego, Marta
    Giner, Angel
    Barastegui, Rebeca
    Fernandez-Clotet, Agnes
    Masamunt, Maica
    Ricart, Elena
    Panes, Julian
    [J]. GASTROENTEROLOGY, 2019, 157 (02) : 432 - +
  • [2] Development and validation of a Simplified Magnetic Resonance Index of Activity (sMaARIA) for Crohn's disease
    Ordas, I.
    Rimola, J.
    Alfaro, I.
    Rodriguez, S.
    Castro, J.
    Gallego, M.
    Giner, A.
    Barastegui, R.
    Vara, A.
    Masamunt, M.
    Ricart, E.
    Panes, J.
    [J]. JOURNAL OF CROHNS & COLITIS, 2018, 12 : S224 - S224
  • [3] DEVELOPMENT AND VALIDATION OF A SIMPLIFIED MAGNETIC RESONANCE INDEX OF ACTIVITY (SMARIA) FOR CROHN'S DISEASE
    Ordas, Ingrid
    Rimola, Jordi
    Alfaro, Ignacio
    Rodriguez, Sonia
    Castro, Jesus
    Gallego, Marta
    Giner, Angel
    Barastegui, Rebeca
    Vara, Alejandro
    Masamunt, Maica
    Ricart, Elena
    Panes, Julian
    [J]. GASTROENTEROLOGY, 2018, 154 (06) : S99 - S99
  • [4] Validation of a Magnetic Resonance Index of Activity for Ileocolonic Crohn's Disease
    Ordas, Ingrid
    Garcia-Bosch, Orlando
    Rodriguez, Sonia
    Aceituno, Montserrat
    Pellise, Maria
    Ricart, Elena
    Rimola, Jordi
    Panes, Julian
    [J]. GASTROENTEROLOGY, 2010, 138 (05) : S75 - S75
  • [5] The development of a magnetic resonance imaging index for fistulising Crohn's disease
    Samaan, M. A.
    Puylaert, C. A. J.
    Levesque, B. G.
    Zou, G. Y.
    Stitt, L.
    Taylor, S. A.
    Shackelton, L. M.
    Vandervoort, M. K.
    Khanna, R.
    Santillan, C.
    Rimola, J.
    Hindryckx, P.
    Nio, C. Y.
    Sandborn, W. J.
    D'Haens, G.
    Feagan, B. G.
    Jairath, V.
    Stoker, J.
    [J]. ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2017, 46 (05) : 516 - 528
  • [6] DEVELOPMENT OF A MAGNETIC RESONANCE ENTEROGRAPHY INDEX FOR ASSESSING SMALL BOWEL STRICTURES IN PATIENTS WITH CROHN'S DISESE: VALIDATION OF METHODS AND ITEM RELIABILITY
    Rieder, Florian
    Baker, Mark E.
    Bruining, David H.
    Fidler, Jeff L.
    Sheedy, Shannon P.
    Heiken, Jay
    Ehman, Eric C.
    Ream, Justin
    Holmes, David
    Inoue, Akitoshi
    Lee, Yong
    Taylor, Stuart
    Stoker, Jaap
    Zou, Guangyong
    Wang, Zhongya
    Ottichilo, Ronald K.
    Panes, Julian
    Rimola, Jordi
    Jairath, Vipul
    Feagan, Brian G.
    Fletcher, Joel G.
    [J]. GASTROENTEROLOGY, 2022, 162 (07) : S774 - S775
  • [7] A magnetic resonance enterography index for assessing small bowel Crohn's disease activity
    Zuo, Ying
    Huang, Wei
    Wei, Juan
    Lan, Xing
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (04) : 2128 - 2142
  • [8] Magnetic resonance Index of Activity (MaRIA) is reliable in assessing response to treatment in patients with Crohn's disease (CD)
    Zhang, Y. -N.
    Liu, Y. -B.
    Xu, J.
    Cao, K. -M.
    Zhang, X. -X.
    Wang, Y. -B.
    Liu, F.
    Duan, B. -S.
    Hu, Y. -D.
    Chu, S. -G.
    [J]. CLINICAL RADIOLOGY, 2024, 79 (02) : 230 - 236
  • [9] Internal fistulas in Crohn disease: magnetic resonance enteroclysis
    K. A. Herrmann
    H. J. Michaely
    C. J. Zech
    J. Seiderer
    M. F. Reiser
    S. O. Schoenberg
    [J]. Abdominal Imaging, 2006, 31 : 675 - 687
  • [10] Internal fistulas in Crohn disease:: magnetic resonance enteroclysis
    Herrmann, K. A.
    Michaely, H. J.
    Zech, C. J.
    Seiderer, J.
    Reiser, M. F.
    Schoenberg, S. O.
    [J]. ABDOMINAL IMAGING, 2006, 31 (06): : 675 - 687