Catheter Tracking and Data Fusion for reducing the X-ray exposition in an Interventional Radiology procedure

被引:0
|
作者
Flores, Jesus Zegarra [1 ]
de lastic, Hugues [1 ]
Oberle, Antoine [1 ]
Radoux, Jean Pierre [1 ]
机构
[1] Parc Innovat, Dept Rech & Innovat Altran, Med Team, Blvd Sebastien Brandt,Bat Gauss CS 20143, F-67404 Illkirch Graffenstaden, France
关键词
Interventional Radiology; Deep learning; Data fusion; U-net; Extended Kalman filter;
D O I
10.1117/12.2553116
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Although the many advantages of Interventional Radiology not only being a minimally invasive surgery but also providing minimal risk of infection and better recuperation for the patient. However, this procedure can cause serious damage (cancer or burnt skin) to the patient and especially to the surgeons if they are exposed for long periods to the X-ray radiation. In the state of art, it has been found new remote catheter navigation system in which the equipment uses magnetic fields for controlling and moving the catheter from an external cabin. Additionally, large equipment needs to be installed in the operating room. In order to limit the doses of X-rays without installing large equipment in the operating room, the aim is to decrease the images coming from X rays imagers using sensors that can be integrated into the catheter (like Fibber Bragg Gratings Sensors inside the catheter or MEMS sensors) to reconstruct an image without the need of continuous imaging. In order to do that, accurate and reliable information on the position of the catheter is required to correct the drift of the catheter's sensors. This position can therefore be obtained by image processing on X-ray images (noisy with artefacts). Previous work done by the Medic@ team has shown that conventional image processing approaches are generally too slow or not precise enough. The use of a U-Net convolutional neural network is then a possible solution for detecting the entire catheter (body and head) and obtaining the coordinates of its end. In this article, we will explain and show our first results using the U-net architecture for detecting the tip and the body of the catheter and a kalman filter used for data fusion to evaluate its efficiency to reducing the quantity of images needed in a curvilinear vessel, using generated data.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Catheter Tracking Using a Convolutional Neural Network for Decreasing Interventional Radiology X-Ray Exposure
    Flores, J. Zegarra
    Radoux, J. P.
    IRBM, 2023, 44 (02)
  • [2] An active pixel sensor to detect diffused X-ray during Interventional Radiology procedure
    Servoli, L.
    Battisti, D.
    Biasini, M.
    Checcucci, B.
    Conti, E.
    Di Lorenzo, R.
    Esposito, A.
    Fano, L.
    Paolucci, M.
    Passeri, D.
    Pentiricci, A.
    Placidi, P.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [3] Evaluation of novel X-ray protective eyewear in reducing the eye dose to interventional radiology physicians
    Endo, Mime
    Haga, Yoshihiro
    Sota, Masahiro
    Tanaka, Akiko
    Otomo, Kazuki
    Murabayashi, Yuuki
    Abe, Mitsuya
    Kaga, Yuji
    Inaba, Yohei
    Suzuki, Msatoshi
    Meguro, Taiichiro
    Chida, Koichi
    JOURNAL OF RADIATION RESEARCH, 2021, 62 (03) : 414 - 419
  • [4] NEW-OLD METHODS OF REDUCING AND MONITORING X-RAY EXPOSURE IN THE INTERVENTIONAL RADIOLOGY ENVIRONMENT
    Mirowski, Mateusz Michal
    MEDYCYNA PRACY, 2021, 72 (01) : 49 - 59
  • [5] X-RAY SCATTER DATA FOR DIAGNOSTIC RADIOLOGY
    DICK, CE
    SOARES, CG
    MOTZ, JW
    PHYSICS IN MEDICINE AND BIOLOGY, 1978, 23 (06): : 1076 - 1085
  • [6] 3D X-ray image guidance in interventional radiology
    Niessen, W. J.
    van de Kraats, E. B.
    Baert, S. A. M.
    van Walsum, Th.
    2007 4TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING : MACRO TO NANO, VOLS 1-3, 2007, : 1000 - 1003
  • [7] X-ray and ultrasound data fusion
    Gautier, S
    Idier, J
    Djafari, AR
    Lavayssiere, B
    1998 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING - PROCEEDINGS, VOL 3, 1998, : 366 - 369
  • [8] Evaluating the performance of a MOSFET dosimeter at diagnostic X-ray energies for interventional radiology
    Chida K.
    Inaba Y.
    Masuyama H.
    Yanagawa I.
    Mori I.
    Saito H.
    Maruoka S.
    Zuguchi M.
    Radiological Physics and Technology, 2009, 2 (1) : 58 - 61
  • [9] Robust Catheter Identification and Tracking in X-Ray Angiographic Sequences
    Fazlali, H. R.
    Karimi, N.
    Soroushmehr, S. M. R.
    Samavi, S.
    Nallamothu, B.
    Derksen, H.
    Najarian, K.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 7901 - 7904
  • [10] Early experience with X-ray magnetic resonance fusion for low-flow vascular malformations in the pediatric interventional radiology suite
    Tiffany J. Hwang
    Erin Girard
    Sphoorti Shellikeri
    Randolph Setser
    Arastoo Vossough
    Victor Ho-Fung
    Anne Marie Cahill
    Pediatric Radiology, 2016, 46 : 413 - 421