Real-world observational study of the evaluation of inhaler techniques in asthma patients

被引:6
|
作者
Pothirat, Chaicharn [1 ]
Chaiwong, Warawut [1 ]
Limsukon, Atikun [1 ]
Phetsuk, Nittaya [1 ]
Chetsadaphan, Nonglak [1 ]
Choomuang, Woranoot [1 ]
Liwsrisakun, Chalerm [1 ]
机构
[1] Chiang Mai Univ, Fac Med, Dept Internal Med, Div Pulm Crit Care & Allergy, Chiang Mai, Thailand
来源
关键词
asthma; inhalation; technique; device; medication; METERED-DOSE INHALER; INHALATION TECHNIQUE; DEVICES; COPD; MANAGEMENT; THERAPY;
D O I
10.12932/AP-210618-0348
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Background: Inhaler devices are a keystone in the management of asthma during the maintenance phase of treatment. Objective: To evaluate techniques for using inhaler devices in asthma patients. Methods: A prospective cross-sectional study was conducted to assess patient compliance with correct techniques for using inhaler devices across three regimens: pressurized metered-dose inhaler (pMDI), Accubalee, and Turbuhalee. The compliance of patients with essential steps for correct device usage in the case of each regimen was recorded. These were recorded when patients presented for a routine visit and one month after receiving face-to-face training. The percentage of compliance between the use of the devices and the risk factors related to incorrect techniques were analyzed by logistic regression analysis. The percentages of incorrect techniques were compared between the two visits using a Chi-squared test. Results: A total of 108 asthma patients (35.2% male), with a mcan age of 57.5 +/- 12.3 years were evaluated. Percentages of incorrect use of Accuhalers, pMDI, and Turbuhalers were 50%, 48%, and 55.6%, respectively. The most common incorrectness's is breath out gently to residual volume (approximately one-third). Previous treatment by a pulmonologist for less than 2 years was the single factor related to incorrect technique (Adjusted OR = 2.8 (95%CI, 1.2-6.3), p = 0.021. Formal training resulted in a statistically significant decrease in percentage of incorrect techniques (52.8% vs. 32.1%, p = 0.02). Conclusion: Inhalation technique in asthma patients was mostly unsatisfactory, especially in patients who had been treated by a pulmonologist for less than 2 years. Face-to-face training significantly improved good technique in all devices.
引用
收藏
页码:96 / 102
页数:7
相关论文
共 50 条
  • [1] Effectiveness of inhaler types for real-world asthma management: retrospective observational study using the GPRD
    Price, David
    Haughney, John
    Sims, Erika
    Ali, Muzammil
    von Ziegenweidt, Julie
    Hillyer, Elizabeth V.
    Lee, Amanda J.
    Chisholm, Alison
    Barnes, Neil
    [J]. JOURNAL OF ASTHMA AND ALLERGY, 2011, 4 : 37 - 47
  • [2] Feasibility of a mobile app to improve inhaler adherence in real-world patients with asthma: A multicentre observational study in Portugal and Spain
    Jacome, C.
    Almeida, R.
    Amaral, R.
    Pereira, A. M.
    Vidal, C.
    Lopez Freire, S.
    Mendez Brea, P.
    Antolin-Amerigo, D.
    De La Hoz Caballer, B.
    Barra Castro, A.
    Gonzalez De Olano, D.
    Todo Bom, A.
    Azevedo, J.
    Leiria Pinto, P.
    Neuparth, N.
    Todo Bom, F.
    Costa, A.
    Chaves Loureiro, C.
    Maia Santos, L.
    Arrobas, A.
    Valerio, M.
    Cardoso, J.
    Emiliano, M.
    Gerardo, R.
    Cidrais Rodrigues, J. C.
    Oliveira, G.
    Carvalho, J.
    Mendes, A.
    Lozoya, C.
    Santos, N.
    Menezes, F.
    Gomes, R.
    Camara, R.
    Rodrigues Alves, R.
    Moreira, A. S.
    Bordalo, D.
    Alves, C.
    Coelho, D.
    Ferreira, J. A.
    Lopes, C.
    Silva, D.
    Vasconcelos, M. J.
    Teixeira, M. F.
    Taborda-Barata, L.
    Calix, M. J.
    Alves, A.
    Almeida Fonseca, J.
    [J]. ALLERGY, 2020, 75 : 372 - 373
  • [3] Use of inhaler devices in elderly patients with respiratory disease: real-world observational study
    Lee, Ha Youn
    Lee, Byoung Jun
    Jung, Keun Bum
    Lim, Hyojung
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2019, 54
  • [4] Evaluation of Inhaler Techniques Among Asthma Patients Seen in Nigeria: An Observational Cross Sectional Study
    Onyedum, C. C.
    Desalu, O. O.
    Nwosu, N., I
    Chukwuka, C. J.
    Ukwaja, K. N.
    Ezeudo, C.
    [J]. ANNALS OF MEDICAL AND HEALTH SCIENCES RESEARCH, 2014, 4 (01) : 67 - 73
  • [5] Real-world treatment of asthma: Inhaler prescriptions and use in Australia
    Blakey, J.
    Bosnic-Anticevich, S.
    Thompson, B.
    Lavoie, K.
    Wiseman, R.
    Hancock, K.
    Plank, M.
    Chapman, K.
    [J]. RESPIROLOGY, 2022, 27 : 91 - 92
  • [6] Real-world asthma management with inhaler devices in Switzerland-results of the asthma survey
    Clarenbach, Christian F.
    Nicod, Laurent P.
    Kohler, Malcolm
    [J]. JOURNAL OF THORACIC DISEASE, 2016, 8 (11) : 3096 - +
  • [7] Real-world efficacy of "fixed triple" single-inhaler combinations in COPD and asthma patients
    Mochizuki, Taichi
    Arai, Hiroyuki
    Inoue, Yasushi
    Ueda, Ryuta
    Nagase, Seisuke
    Umeda, Akira
    To, Yasuo
    Tsushima, Kenji
    [J]. RESPIROLOGY, 2023, 28 : 311 - 312
  • [8] Persistence of Eosinophilic Asthma Endotype and Clinical Outcomes: A Real-World Observational Study
    Tran, Trung N.
    Kerkhof, Marjan
    Carter, Victoria
    Price, David B.
    [J]. JOURNAL OF ASTHMA AND ALLERGY, 2021, 14 : 727 - 742
  • [9] Real-world evidence with extrafine single-inhaler triple therapy in asthma: the TriMaximize study
    Gessner, C.
    Akyildiz, B.
    Cesarz, K.
    Sauer, A.
    Bogoevska, V
    Criee, P. C.
    [J]. PNEUMOLOGIE, 2022, 76 : S7 - S8
  • [10] Device type and real-world effectiveness of asthma combination therapy: An observational study
    Price, David
    Roche, Nicolas
    Virchow, J. Christian
    Burden, Annie
    Ali, Muzammil
    Chisholm, Alison
    Lee, Amanda J.
    Hillyer, Elizabeth V.
    von Ziegenweidt, Julie
    [J]. RESPIRATORY MEDICINE, 2011, 105 (10) : 1457 - 1466