Methodology for High Accuracy Contact Angle Measurement

被引:55
|
作者
Kalantarian, A. [1 ]
David, R. [1 ]
Neumann, A. W. [1 ]
机构
[1] Univ Toronto, Dept Mech & Ind Engn, Toronto, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
DROP SHAPE-ANALYSIS; SOLID-SURFACE TENSIONS; INTERFACIAL-TENSION; FLUID INTERFACES; RECENT PROGRESS; LIQUID BRIDGES; ANALYSIS ADSA; AUTOMATION; PENDANT;
D O I
10.1021/la902016j
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new version of axisymmetric drop shape analysis (ADSA) called ADSA-NA (ADSA-no apex) wits developed for measuring interfacial properties for drop configurations without an apex. ADSA-NA facilitates contact angle measurements on drops with a capillary protruding into the drop. Thus a much simpler experimental Setup, not involving formation of a complete drop from below through a hole in the test surface, may be used. The contact angles or long-chained alkanes on a commercial fluoropolymer, Teflon AF 1600, were measured using the new method. A new numerical scheme was incorporated into the image processing to improve the location of the contact points of the liquid meniscus with the solid substrate to subpixel resolution. The images acquired in the experiments were also analyzed by a different drop shape technique called theoretical image fitting analysis-axisymmetric interfaces (TIFA-AI). The results were compared with literature values obtained by means of the standard ADSA for sessile drops with the apex. Comparison of the results from ADSA-NA with those from TIFA-AI and ADSA reveals that, with different numerical strategies and experimental setups, contact angles can be measured with an accuracy of less than 0.2 degrees. Contact angles and surface tensions measured from drops with no apex, i.e., by means of ADSA-NA and TIFA-AI, were considerably less scattered than those from complete drops with apex. ADSA-NA was also used to explore sources of improvement in contact angle resolution. It wits found that using an accurate value of surface tension as an input enhances the accuracy of contact. angle measurements.
引用
收藏
页码:14146 / 14154
页数:9
相关论文
共 50 条
  • [1] Modeling and Measurement of Contact Angle Hysteresis on Textured High-Contact-Angle Surfaces
    Koch, Brendan M. L.
    Amirfazli, A.
    Elliott, Janet A. W.
    JOURNAL OF PHYSICAL CHEMISTRY C, 2014, 118 (32): : 18554 - 18563
  • [2] Contact angle measurement and contact angle interpretation
    Kwok, DY
    Neumann, AW
    ADVANCES IN COLLOID AND INTERFACE SCIENCE, 1999, 81 (03) : 167 - 249
  • [3] A simple method for measuring the superhydrophobic contact angle with high accuracy
    Hung, Yi-Lin
    Chang, Yao-Yuan
    Wang, Meng-Jiy
    Lin, Shi-Yow
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (06):
  • [4] Measurement of contact angle and work of adhesion at high temperature
    Eustathopoulos, N
    Sobczak, N
    Passerone, A
    Nogi, K
    JOURNAL OF MATERIALS SCIENCE, 2005, 40 (9-10) : 2271 - 2280
  • [5] Measurement of contact angle and work of adhesion at high temperature
    N. Eustathopoulos
    N. Sobczak
    A. Passerone
    K. Nogi
    Journal of Materials Science, 2005, 40 : 2271 - 2280
  • [6] Physics of contact angle measurement
    Decker, EL
    Frank, B
    Suo, Y
    Garoff, S
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1999, 156 (1-3) : 177 - 189
  • [7] An Analysis of Contact Angle Measurement
    Shieh, Sarah
    Clean Tech, 2001, 1 (03):
  • [8] Contact angle measurement with a smartphone
    Chen, H.
    Muros-Cobos, Jesus L.
    Amirfazli, A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (03):
  • [9] A new approach to contact angle measurement and effects of evaporation on the contact angle
    Cakir, M. Faruk
    REVISTA MEXICANA DE FISICA, 2024, 70 (03)
  • [10] High accuracy angle measurement method for remote sensing scanning system
    Chi Dongnan
    Zhao Xin
    Ling Long
    PROCEEDINGS OF 2015 IEEE 12TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), VOL. 3, 2015, : 1508 - 1512