Automatic registration of MR and SPECT images for treatment planning in prostate cancer

被引:11
|
作者
Lee, ZH
Nagano, KK
Duerk, JL
Sodee, DB
Wilson, DL
机构
[1] Univ Hosp Cleveland, Dept Radiol, Sch Med, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Sch Engn, Dept Biomed Engn, Cleveland, OH 44106 USA
关键词
images; processing; monoclonal antibodies; prostate neoplasms; MR; radionuclide studies;
D O I
10.1016/S1076-6332(03)80088-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. To aid in surgical and radiation therapy planning for prostate adenocarcinoma, a general-purpose automatic registration method that is based on mutual information was used to align magnetic resonance (MR) images and single photon emission computed tomographic (SPECT) images of the pelvis and prostate. Materials and Methods. The authors assessed the effects of various factors on alignment between pairs of MR and SPECT images, including the use of particular pulse sequences in MR imaging, image voxel intensity scaling, the use of different regions on the MR-SPECT histogram, spatial masking of nonoverlapping visual data between images, and multiresolution optimization. A mutual information algorithm was used as the cost function for automatic registration. Automatic registration was deemed acceptable when it resulted in a transformation with less than 2 voxel units (6 mm) difference in translation and less than 2degrees difference in rotation from that obtained with manual registration performed independently by nuclear medicine radiologists. Results. Paired sets of MR and SPECT image volumes from four of five patients were successfully registered. For successful registration, MR images must be optimal and registration must be performed at full spatial resolution and at the full intensity range. Masking, cropping, and the normalization of mutual information, used to register partially overlapping MR-SPECT volumes, were not successful. Multiresolution optimization had little effect on the accuracy and speed of the registration. Conclusion. Automatic registration between MR and SPECT images of the pelvis can be achieved when data acquisition and image processing are pet-formed properly. It should prove useful for prostate cancer diagnosis, staging, and treatment planning. (C) AUR, 2003.
引用
收藏
页码:673 / 684
页数:12
相关论文
共 50 条
  • [1] Automatic registration of MR and SPECT
    DeMunck, JC
    Dubois, EA
    Habraken, JBA
    Verster, FC
    VanHerk, M
    [J]. PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 1996, 65 : PH203 - PH203
  • [2] Impact of CT-MR registration imprecision on treatment planning for prostate cancer
    Elen, A.
    Crijns, W.
    Isebaert, S.
    Haustermans, K.
    Maes, F.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S65 - S65
  • [3] Semi-automatic Deformable Registration of Prostate Mr Images to Pathological Slices
    Mazaheri, Yousef
    Bokacheva, Louisa
    Kroon, Dirk-Jan
    Akin, Oguz
    Hricak, Hedvig
    Chamudot, Daniel
    Fine, Samson
    Koutcher, Jason A.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (05) : 1149 - 1157
  • [4] Deep Learning-Based Registration of MR and Treatment Planning Ultrasound Images for HDR Prostate Brachytherapy
    Chen, Y.
    Xing, L.
    Yu, L.
    Liu, W.
    Fahimian, B. P.
    Niedermayr, T. R.
    Gensheimer, M.
    Bagshaw, H. P.
    Buyyounouski, M. K.
    Han, B.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E109 - E109
  • [5] Nonrigid registration of multitemporal CT and MR images for radiotherapy treatment planning
    Slagmolen, Pieter
    Loeckx, Dirk
    Roels, Sarah
    Geets, Xavier
    Maes, Frederik
    Haustermans, Karin
    Suetens, Paul
    [J]. BIOMEDICAL IMAGE REGISTRATION, PROCEEDINGS, 2006, 4057 : 297 - 305
  • [6] Fast registration technique of MR and SPECT brain images
    Sun, YN
    Huang, SC
    Chang, TC
    Chen, FJ
    Chiu, NT
    [J]. MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 : 1442 - 1449
  • [7] Automatic PBS Treatment Planning for Prostate Cancer
    Zhang, J.
    Durci, M.
    Wu, H.
    Rosen, L.
    Ding, X.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3364 - 3364
  • [8] Towards integrating functional imaging in the treatment of prostate cancer with radiation: The registration of the MR spectroscopy imaging to ultrasound/CT images and its implementation in treatment planning
    Mizowaki, T
    Cohen, GN
    Fung, AYC
    Zaider, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 54 (05): : 1558 - 1564
  • [9] Automatic registration of EPI and DRR images for treatment planning and delivery verification
    Liu, J.
    Drzymala, R.
    Bradley, J.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2019 - 2019
  • [10] A priori registration of SPECT projections and MR/CT images for SPECT reconstruction improvement
    Bouchard, V
    Cinquin, P
    Desbat, L
    Joubert, AF
    Lavallee, S
    Peria, O
    [J]. CVRMED-MRCAS'97: FIRST JOINT CONFERENCE - COMPUTER VISION, VIRTUAL REALITY AND ROBOTICS IN MEDICINE AND MEDICAL ROBOTICS AND COMPUTER-ASSISTED SURGERY, 1997, 1205 : 491 - 500