Ternary Electrochemiluminescence Biosensor Based on DNA Walkers and AuPd Nanomaterials as a Coreaction Accelerator for the Detection of miRNA-141

被引:50
|
作者
Wang, Qian [1 ,2 ]
Liu, Yaqi [1 ]
Wang, Xuefeng [1 ]
Wang, Fengyi [1 ]
Zhang, Lina [3 ]
Ge, Shenguang [1 ]
Yu, Jinghua [2 ]
机构
[1] Univ Jinan, Inst Adv Interdisciplinary Res, Jinan 250022, Peoples R China
[2] Univ Jinan, Sch Chem & Chem Engn, Jinan 250022, Peoples R China
[3] Univ Jinan, Shandong Prov Key Lab Preparat & Measurement Bldg, Jinan 250022, Peoples R China
基金
中国国家自然科学基金;
关键词
electrochemiluminescence; microRNA-141; three-dimensional reduced graphene oxide@Au nanoparticles; AuPd nanoparticles; DNA walker; ELECTROCHEMICAL BIOSENSOR; SIGNAL AMPLIFICATION; MICRORNA DETECTION; ONE-STEP; STRATEGY; NANOMACHINE; DELIVERY; WALKING; CIRCUIT; PROBES;
D O I
10.1021/acsami.1c05368
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this study, a ternary electrochemiluminescence (ECL) sensing platform coupled with a multiple signal amplification strategy was proposed for ultrasensitive detection of miRNA-141. The initial signal amplification was achieved via three-dimensional reduced graphene oxide (3D-rGO)@Au nanoparticles (NPs) to form an excellent conductive layer. Then, AuPd NPs as a coreaction accelerator was introduced into the N-(4-aminobutyl)-N-(ethylisoluminol) (ABEI)-H2O2 system to facilitate the transformation from H2O2 to excess superoxide anion radicals (O-2(center dot-)), which further amplified the ECL emission of ABEI, leading to a significant increase of the ECL signal. Meanwhile, in the presence of miRNA-141 and T7 Exonuclease (T7 Exo), the self-assembled DNA swing arm can be driven to walk autonomously. The DNA walker reaction could result in the release of numerous labeled luminophores, which could react to achieve an extremely weak ECL signal. Surprisingly, the established ECL sensor platform for the detection of miRNA-141 demonstrated excellent sensitivity with a low detection limit of 31.9 aM in the concentration range from 100 aM to 1 nM. Consequently, the designed strategy greatly improves the luminous efficiency of the ternary ECL system and provides a special approach for the detection of nucleic acids and biomarkers in clinical and biochemical analysis.
引用
收藏
页码:25783 / 25791
页数:9
相关论文
共 50 条
  • [1] Ternary Electrochemiluminescence System Based on Rubrene Microrods as Luminophore and Pt Nanomaterials as Coreaction Accelerator for Ultrasensitive Detection of MicroRNA from Cancer Cells
    Liu, Jia-Li
    Tang, Zhi-Ling
    Zhuo, Ying
    Chai, Ya-Qin
    Yuan, Ruo
    ANALYTICAL CHEMISTRY, 2017, 89 (17) : 9108 - 9115
  • [2] DNA strand displacement-based sensor for the detection of miRNA-141 in serum samples
    Zhang, Qiongdan
    Luo, Xi
    Liu, Qingyi
    Long, Kang
    Han, Qiqi
    Wang, Wei
    Li, Bin
    Wang, Huizhen
    CHEMICAL BIOLOGY LETTERS, 2025, 12 (02):
  • [3] Ternary electrochemiluminescence biosensor based on black phosphorus quantum dots doped perylene derivative and metal organic frameworks as a coreaction accelerator for the detection of chloramphenicol
    Wen, Jing
    Jiang, Ding
    Shan, Xueling
    Wang, Wenchang
    Xu, Fangmin
    Shiigi, Hiroshi
    Chen, Zhidong
    MICROCHEMICAL JOURNAL, 2022, 172
  • [4] Construction of a Polarity-Switchable Photoelectrochemical Biosensor for Ultrasensitive Detection of miRNA-141
    Niu, Xiankang
    Lu, Changtong
    Su, Dan
    Wang, Fang
    Tan, Weihong
    Qu, Fengli
    ANALYTICAL CHEMISTRY, 2021, 93 (40) : 13727 - 13733
  • [5] MnOx MFs as a coreaction accelerator for the construction of a novel ternary electrochemiluminescence system: ultrasensitive detection of microRNA
    Yang, Rong
    Liu, Jia-Li
    Chai, Ya-Qin
    Yuan, Ruo
    CHEMICAL COMMUNICATIONS, 2020, 56 (06) : 976 - 979
  • [6] Ruthenium-based metal organic framework (Ru-MOF)-derived novel Faraday-cage electrochemiluminescence biosensor for ultrasensitive detection of miRNA-141
    Shao, Huili
    Lu, Jing
    Zhang, Qingqing
    Hu, Yufang
    Wang, Sui
    Guo, Zhiyong
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 268 : 39 - 46
  • [7] Photoelectrochemical biosensor based on CdS quantum dots anchored h-BN nanosheets and tripodal DNA walker for sensitive detection of miRNA-141
    Wang, Fengyi
    Liu, Yaqi
    Zhang, Lu
    Zhang, Zuhao
    Huang, Chuan
    Zang, Dejin
    Wang, Haiqing
    Ge, Shenguang
    Yu, Jinghua
    ANALYTICA CHIMICA ACTA, 2022, 1226
  • [8] Electrochemiluminescence Peptide-Based Biosensor with Hetero-Nanostructures as Coreaction Accelerator for the Ultrasensitive Determination of Tryptase
    Wu, Fang-Fang
    Zhou, Ying
    Zhang, Han
    Yuan, Ruo
    Chai, Ya-Qin
    ANALYTICAL CHEMISTRY, 2018, 90 (03) : 2263 - 2270
  • [9] Photoswitchable CRISPR/Cas12a-Amplified and Co3O4@Au Nanoemitter Based Triple-Amplified Diagnostic Electrochemiluminescence Biosensor for Detection of miRNA-141
    Wang, Qian
    Zhang, Zuhao
    Zhang, Lu
    Liu, Yunqing
    Xie, Li
    Ge, Shenguang
    Yu, Jinghua
    ACS APPLIED MATERIALS & INTERFACES, 2022, 14 (29) : 32960 - 32969
  • [10] Ultrasensitive SQDs-based electrochemiluminescence assay for determination of miRNA-141 with dual-amplification of co-reaction accelerators and DNA walker
    Ji, Kailun
    Wang, Yifei
    Mao, Lebao
    Wang, Yuzhe
    Zhang, Xiuhua
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 345