Immediate and chronic effects of AV-delay optimization in patients with cardiac resynchronization therapy

被引:43
|
作者
Hardt, Stefan E. [1 ]
Yazdi, Said Hashem Fani [1 ]
Bauer, Alexander [1 ]
Filusch, Arthur [1 ]
Korosoglou, Grigorlos [1 ]
Hansen, Alexander [1 ]
Bekeredjian, Raffi [1 ]
Ehlermann, Philipp [1 ]
Remppis, Andrew [1 ]
Katus, Hugo A. [1 ]
Kuecherer, Helmut F. [1 ]
机构
[1] Heidelberg Univ, Dept Cardiol, D-69120 Heidelberg, Germany
关键词
cardiac resynchronization; heart failure; echocardiography;
D O I
10.1016/j.ijcard.2006.03.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Acute changes of the AV-delay in CRT patients have a significant impact on hemodynamics. However, the chronic functional effects of AV-delay optimization have not been systematically examined despite of their potential role for chronic functional improvement. Methods: Therefore, in this study we investigated whether optimization of AV-delay in CRT patients as assessed by echocardiographic measurement of the velocity time integral of the left ventricular outflow tract (LVOT-VTI) chronically changes (1) echocardiographic parameters of systolic and diastolic left ventricular function, (2) walking distance in the 6-min walk test, (3) levels of NT-proBNP and (4) quality of life as assessed by a standard questionnaire, 3 3 patients underwent optimization of AV-delay 3 1 8 weeks after initiation of CRT. Follow up (FU) was conducted 43 5 days later. Results: E/Ea, the ratio of peak E-wave of mitral inflow and of TDI of the mitral annulus, significantly decreased immediately post-optimization (11 +/- 1 vs. 14 +/- 1 at baseline, p < 0.05) and further decreased at FU (8 +/- 1, p < 0.05 vs. immediately post-optimization) indicating improvement of diastolic function, while traditional parameters of diastolic function derived from pulse wave Doppler remained unchanged. There was a slight increase of LV-ejection fraction as assessed by echocardiography acutely after optimization (baseline: 25 +/- 2%, optimized: 28 +/- 1%, p < 0.05), while LV-ejection fraction at FU did not differ from baseline. 6-min walk test improved from 449 +/- 17 m (baseline) to 475 +/- 17 m at FU (p < 0.05). During this period NT-proBNP significantly decreased from 3193 +/- 765 ng/l to 2593 +/- 675 ng/l (p < 0.05). Quality of life was unchanged at FU. Conclusion: This study demonstrates for the first time chronic functional improvement due to AV-delay optimization in patients with CRT. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:318 / 325
页数:8
相关论文
共 50 条
  • [1] Vectorcardiography for Easy and Reliable Optimization of Av-delay in Patients with Cardiac Resynchronization Therapy
    van Deursen, Caroline C.
    Wecke, Liliane
    van Everdingen, Wouter
    Stahlberg, Marcus
    Janssen, Michel H.
    Vernooy, Kevin
    Prinzen, Frits W.
    CIRCULATION, 2012, 126 (21)
  • [2] Beneficial chronic effects of AV-Delay optimization in patiens with cardiac resynchronisation therapy
    Hardt, SE
    Yazdi, SHF
    Bauer, A
    Filusch, A
    Ehlermann, P
    Staritz, P
    Korosoglou, G
    Hansen, A
    Remppis, A
    Schoels, W
    Katus, HA
    Kuecherer, HF
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 100A - 100A
  • [3] The Effect of Interventricular Delay on AV Optimization for Cardiac Resynchronization Therapy
    Gold, Michael R.
    Yu, Yinghong
    Singh, Jagmeet P.
    Stein, Kenneth M.
    Birgersdotter-Green, Ulrika
    Wold, Nicholas
    Meyer, Timothy E.
    Ellenbogen, Kenneth A.
    CIRCULATION, 2016, 134
  • [4] Effects of AV-delay optimization on hemodynamic parameters in patients with VDD pacemakers
    Krychtiuk, Konstantin A.
    Nuernberg, Michael
    Volker, Romana
    Pachinger, Linda
    Jarai, Rudolf
    Freynhofer, Matthias K.
    Wojta, Johann
    Huber, Kurt
    Weiss, Thomas W.
    WIENER KLINISCHE WOCHENSCHRIFT, 2014, 126 (9-10) : 270 - 277
  • [5] Rate-dependent AV delay optimization in cardiac resynchronization therapy
    Scharf, C
    Li, P
    Muntwyler, J
    Chugh, A
    Oral, H
    Pelosi, F
    Morady, F
    Armstrong, WF
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (04): : 279 - 284
  • [6] Computer model for the optimization of AV and VV delay in cardiac resynchronization therapy
    Matthias Reumann
    Dima Farina
    Raz Miri
    Stephan Lurz
    Brigitte Osswald
    Olaf Dössel
    Medical & Biological Engineering & Computing, 2007, 45 : 845 - 854
  • [7] Computer model for the optimization of AV and VV delay in cardiac resynchronization therapy
    Reumann, Matthias
    Farina, Dima
    Miri, Raz
    Lurz, Stephan
    Osswald, Brigitte
    Doessel, Olaf
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2007, 45 (09) : 845 - 854
  • [8] The effect of left ventricular electrical delay on AV optimization for cardiac resynchronization therapy
    Gold, Michael R.
    Yu, Yinghong
    Singh, Jagmeet P.
    Stein, Kenneth M.
    Birgersdotter-Green, Ulrika
    Meyer, Timothy E.
    Seth, Milan
    Ellenbogen, Kenneth A.
    HEART RHYTHM, 2013, 10 (07) : 988 - 993
  • [9] Effects of AV-delay optimization on hemodynamic parameters in patients with VDD pacemakersHämodynamische Effekte der AV-Delay Optimierung in Patienten mit VDD-Schrittmachern
    Konstantin A. Krychtiuk
    Michael Nürnberg
    Romana Volker
    Linda Pachinger
    Rudolf Jarai
    Matthias K. Freynhofer
    Johann Wojta
    Kurt Huber
    Thomas W. Weiss
    Wiener klinische Wochenschrift, 2014, 126 : 270 - 277
  • [10] Maximizing Efficiency of Alternation Algorithms for Hemodynamic Optimization of the AV Delay of Cardiac Resynchronization Therapy
    Whinnett, Zachary I.
    Nott, Gemma
    Davies, Justin E. R.
    Willson, Keith
    Manisty, Charlotte H.
    Kanagaratnam, Prapa
    Peters, Nicholas S.
    Davies, D. Wyn
    Hughes, Alun D.
    Mayet, Jamil
    Francis, Darrel P.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (02): : 217 - 225