A new EEG recording system for passive dry electrodes

被引:111
|
作者
Gargiulo, Gaetano [1 ,2 ]
Calvo, Rafael A. [1 ]
Bifulco, Paolo [2 ]
Cesarelli, Mario [2 ]
Jin, Craig [1 ]
Mohamed, Armin [3 ]
van Schaik, Andre [1 ]
机构
[1] Univ Sydney, Sch Elect & Informat Engn, Sydney, NSW 2006, Australia
[2] Univ Naples Federico 2, DIBET, Naples, Italy
[3] Royal Prince Alfred Hosp, Sydney, NSW, Australia
关键词
EEG; Passive dry electrodes; Brain-computer interfaces;
D O I
10.1016/j.clinph.2009.12.025
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: We present a new, low power EEG recording system with an ultra-high input impedance that enables the use of long-lasting, passive dry electrodes. It incorporates Bluetooth wireless connectivity and is designed to be suitable for long-term monitoring during daily activities. Methods: The new EEG system is compared to a standard and clinically available reference EEG system using wet electrodes in three separate sets of experiments. In the first two experiments, each dry electrode was surrounded by four standard wet electrodes and the alpha and mu-rhythms were recorded. In the third experiment, serial monopolar (referred to the left ear) recordings of. ash visual evoked potential were performed using the new EEG system and a reference system. Results: These experiments showed that the signal recorded using the new EEG system is almost identical to that recorded with standard clinical EEG equipment; our measurements showed that the correlation coefficient between the dry electrode recordings and the average of the four standard electrodes surrounding each dry electrode is greater than 0.85. Conclusion: We conclude that the new EEG system performs similarly to reference EEG systems, while providing the advantages of portability, ease of application and minimal scalp preparation. Significance: The proposed system using passive dry electrodes suitable for single use while performing as good as standard EEG equipment provides ease of application and minimal scalp preparation. (C) 2009 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:686 / 693
页数:8
相关论文
共 50 条
  • [1] Review of semi-dry electrodes for EEG recording
    Li, Guang-Li
    Wu, Jing-Tao
    Xia, Yong-Hui
    He, Quan-Guo
    Jin, Hong-Guang
    [J]. JOURNAL OF NEURAL ENGINEERING, 2020, 17 (05)
  • [2] High and dry? Comparing active dry EEG electrodes to active and passive wet electrodes
    Mathewson, Kyle E.
    Harrison, Tyler J. L.
    Kizuk, Sayeed A. D.
    [J]. PSYCHOPHYSIOLOGY, 2017, 54 (01) : 74 - 82
  • [3] A mobile EEG system with dry electrodes
    Gargiulo, Gaetano
    Bifulco, Paolo
    Calvo, Rafael A.
    Cesarelli, Mario
    Jin, Craig
    van Schaik, Andre
    [J]. 2008 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE - INTELLIGENT BIOMEDICAL SYSTEMS (BIOCAS), 2008, : 273 - +
  • [4] Impedance and Noise of Passive and Active Dry EEG Electrodes: A Review
    Habibzadeh Tonekabony Shad, Erwin
    Molinas, Marta
    Ytterdal, Trond
    [J]. IEEE SENSORS JOURNAL, 2020, 20 (24) : 14565 - 14577
  • [5] A Wearable Ear-EEG Recording System Based on Dry-Contact Active Electrodes
    Zhou, Xiong
    Li, Qiang
    Kilsgaard, Soren
    Moradi, Farshad
    Kappel, Simon L.
    Kidmose, Preben
    [J]. 2016 IEEE SYMPOSIUM ON VLSI CIRCUITS (VLSI-CIRCUITS), 2016,
  • [6] Systematic comparison between a wireless EEG system with dry electrodes and a wired EEG system with wet electrodes
    Kam, Julia W. Y.
    Griffin, Sandon
    Shen, Alan
    Patel, Shawn
    Hinrichs, Hermann
    Heinze, Hans-Jochen
    Deouell, Leon Y.
    Knight, Robert T.
    [J]. NEUROIMAGE, 2019, 184 : 119 - 129
  • [7] Dry EEG Electrodes
    Lopez-Gordo, M. A.
    Sanchez-Morillo, D.
    Pelayo Valle, F.
    [J]. SENSORS, 2014, 14 (07) : 12847 - 12870
  • [8] Soft, Comfortable Polymer Dry Electrodes for High Quality ECG and EEG Recording
    Chen, Yun-Hsuan
    Op de Beeck, Maaike
    Vanderheyden, Luc
    Carrette, Evelien
    Mihajlovic, Vojkan
    Vanstreels, Kris
    Grundlehner, Bernard
    Gadeyne, Stefanie
    Boon, Paul
    Van Hoof, Chris
    [J]. SENSORS, 2014, 14 (12): : 23758 - 23780
  • [9] A DRY ELECTRODE FOR EEG RECORDING
    TAHERI, BA
    KNIGHT, RT
    SMITH, RL
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1994, 90 (05): : 376 - 383
  • [10] A NEW TECHNIQUE FOR APPLYING SCALP ELECTRODES FOR INTRAOPERATIVE EEG RECORDING
    BONNEU, JJ
    HEAD, AS
    ARTRU, AA
    CHADWICK, HS
    COLLEY, PS
    [J]. ANESTHESIOLOGY, 1984, 60 (05) : 523 - 524