Fiber length variability within the flexor carpi ulnaris and flexor carpi radialis muscles:: Implications for surgical tendon transfer

被引:20
|
作者
Fridén, J
Lovering, RA
Lieber, RL
机构
[1] Vet Affairs Med Ctr, Dept Orthopaed 9151, San Diego, CA 92161 USA
[2] Univ Calif San Diego, Dept Orthopaed, San Diego, CA 92161 USA
[3] Univ Calif San Diego, Dept Bioengn, San Diego, CA 92161 USA
[4] Vet Adm Med Ctr, Dept Bioengn, San Diego, CA 92161 USA
[5] Vet Adm Med Ctr, Dept Orthopaed, San Diego, CA 92161 USA
[6] Sahlgrens Univ Hosp, Dept Hand Surg, S-41345 Gothenburg, Sweden
[7] Univ Maryland, Dept Phys Therapy & Rehabil Sci, Baltimore, MD 21201 USA
来源
关键词
hand surgery; muscle; muscle architecture; tendon transfer;
D O I
10.1016/j.jhsa.2004.04.028
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to understand the detailed architectural properties of the human flexor carpi radialis (FCR) and flexor carpi ulnaris (FCU) muscles and their implications for tendon transfer surgery. Methods: Muscle fiber length was measured in 6 separate regions of the FCU and FCR from 10 cadaveric specimens. Sarcomere length was measured by laser diffraction for normalization. Moment arms were estimated by measuring tendon excursion with respect to joint angle. The position of entry of the motor nerve branches into each muscle also was measured to establish limits for the safe length of muscle mobilization. Results: Muscle fiber length varied significantly along both the FCU and FCR. Fiber length variability in the FCU was twice that of the FCR. Although the average fiber length for both muscles across all regions was similar (62.6 +/- 2.1 mm for the FCR and 63.1 +/- 4.0 mm for the FCU), the proximal fibers of the FCU were longer compared with the proximal fibers of the FCR and the distal fibers of the FCU were shorter compared with the distal fibers of the FCR. The 99% confidence interval for the second nerve branch entry into the muscles was located similar to69 mm distal to the medial epicondyle for the FCU and approximately 73 mm distal for the FCR. Conclusions: These data show different designs of both the FCU and the FCR. The functional significance of fiber length variability is not clear but imply that, when used in tendon transfer, the properly mobilized FCU has a much greater excursion. Copyright (C) 2004 by the American Society for Surgery of the Hand.
引用
下载
收藏
页码:909 / 914
页数:6
相关论文
共 50 条
  • [1] Intraoperative measurement and biomechanical modeling of the flexor carpi ulnaris to extensor carpi radialis longus tendon transfer
    Lieber, RL
    Friden, J
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1997, 119 (04): : 386 - 391
  • [2] Intraoperative measurement and biomechanical modeling of the flexor carpi ulnaris-to-extensor carpi radialis longus tendon transfer
    Lieber, R.L.
    Fridén, J.
    Journal of Biomechanical Engineering, 1997, 119 (04): : 386 - 391
  • [3] The supination effect of tendon transfer of the flexor carpi ulnaris to the extensor carpi radialis brevis or longus: A cadaveric study
    Van Heest, AE
    Murthy, NS
    Sathy, MR
    Wentorf, FA
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1999, 24A (05): : 1091 - 1096
  • [4] Calcification about the flexor carpi ulnaris tendon
    Milch, H
    Green, HH
    ARCHIVES OF SURGERY, 1938, 36 (04) : 660 - 671
  • [5] Combined flexor carpi ulnaris and flexor carpi radialis transfer for restoring elbow function after brachial plexus injury
    Atthakomol, Pichitchai
    Ozkan, Sezai
    Chen, Neal
    Lee, Sang-Gil
    BMJ CASE REPORTS, 2019, 12 (07)
  • [6] Bilateral Flexor Carpi Radialis Brevis and Unilateral Flexor Carpi Ulnaris Brevis Muscle: Case Report
    Chong, Simon Jeffery
    Al-Ani, Sami
    Pinto, Clinton
    Peat, Bruce
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2009, 34A (10): : 1868 - 1871
  • [7] Independent function in a tendon transfer of the split flexor carpi ulnaris
    Lim, AYT
    Kumar, V
    Pereira, BP
    Hua, J
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1999, 104 (06) : 1742 - 1743
  • [8] Assessment of Flexor carpi ulnaris function for tendon transfer surgery
    Kreulen, Mick
    Smeulders, Mark J. C.
    JOURNAL OF BIOMECHANICS, 2008, 41 (10) : 2130 - 2135
  • [9] Flexor Carpi Radialis to Palmaris Longus Tendon Transfer for Spontaneous Rupture of the Flexor Carpi Radialis Tendon-A Review of an Uncommon Finding and Surgical Technique for Operative Correction
    Shearin, Jonathan Winkworth
    Walters, Brian
    Yang, S. Steven
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2016, 21 (03): : 417 - 421
  • [10] ANATOMICAL LOCALIZATION OF THE FLEXOR CARPI RADIALIS AND FLEXOR CARPI ULNARIS MOTOR NUCLEI IN THE CAT SPINAL-CORD
    IWAMOTO, GA
    HABER, LH
    DIXON, JA
    GONYEA, WJ
    ANATOMICAL RECORD, 1980, 196 (03): : A85 - A86