Identification of robust focus measure functions for the automated capturing of focused images from Ziehl-Neelsen stained sputum smear microscopy slide

被引:10
|
作者
Shah, M. I. [1 ]
Mishra, S. [1 ]
Sarkar, M. [2 ]
Rout, C. [1 ]
机构
[1] Jaypee Univ Informat Technol, Dept Biotechnol & Bioinformat, Solan 173234, Himachal Prades, India
[2] Indira Gandhi Med Coll, Dept Pulm Med, Shimla 171001, India
关键词
image analysis; focus measure function; autofocus; automated microscopy; bright-field microscopy; Gaussian derivative; tuberculosis; FLUORESCENCE MICROSCOPY; AUTOFOCUS ALGORITHMS; TUBERCULOSIS; MYCOBACTERIA; DIAGNOSIS; SHAPE;
D O I
10.1002/cyto.a.23142
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Capturing of the best-focused image using focus measure function (FMF) from a stack of images acquired at different focus distances is a crucial step in automatic microscopy development. Detection of bacilli present in Ziehl-Neelsen (ZN) stained sputum smears conventional microscope (CM) images is critical to disease diagnosis. Studies have revealed that the performances of FMFs are sensitive to image contents and background noise. In this article, 24 diverse FMFs were implemented on 31 stacks of CM's field of view images acquired from three different microscopes to determine the best-focused one. Seven FMFs achieved the accuracies of greater than 90%. Accuracy, focus error, and false maxima were calculated for each FMF, and overall score and ranking were also calculated for better interpretation. Preprocessing techniques such as filtering and image distortions (noise, contrast, saturation, illumination, etc.) were performed to evaluate the robustness of every FMF. Gaussian derivative, steerable filters, Tenengrad, and Hemli and Scherer's mean FMFs were identified as the most robust and accurate functions with the accuracy >90%. These FMFs have a relatively less focus error and false maxima rate. Full widths at half maximum of these four FMFs were also computed to determine their efficacy for the optimization process. These four FMFs can be implemented for automated capturing of the image from ZN-stained sputum smear slide. Gaussian derivative FMF can also be used effectively for both CM and fluorescence microscope's field of view image stacks to determine the best-focused one from each stack. (c) 2017 International Society for Advancement of Cytometry
引用
收藏
页码:800 / 809
页数:10
相关论文
共 4 条
  • [1] Segmentation of Touching Mycobacterium Tuberculosis from Ziehl-Neelsen Stained Sputum Smear Images
    Xu, Chao
    Zhou, Dongxiang
    Liu, Yunhui
    MIPPR 2015: AUTOMATIC TARGET RECOGNITION AND NAVIGATION, 2015, 9812
  • [2] Automated Segmentation Procedure for Ziehl-Neelsen Stained Tissue Slide Images
    Riza, Bob Subhan
    Mashor, M. Y.
    Osman, M. K.
    Jaafar, H.
    2017 5TH INTERNATIONAL CONFERENCE ON CYBER AND IT SERVICE MANAGEMENT (CITSM 2017), 2017, : 386 - 390
  • [3] Ziehl-Neelsen sputum smear microscopy image database: A resource to facilitate automated bacilli detection for tuberculosis diagnosis
    Shah M.I.
    Mishra S.
    Yadav V.K.
    Chauhan A.
    Sarkar M.
    Sharma S.K.
    Rout C.
    Rout, Chittaranjan (chittaranjan.rout@juit.ac.in), 1600, SPIE (04):
  • [4] Creating a virtual slide map from sputum smear images for region-of-interest localisation in automated microscopy
    Patel, Bhavin
    Douglas, Tania S.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2012, 108 (01) : 38 - 52