Investigation on the performance of a thick ceramic gas electron multiplier

被引:2
|
作者
Hu, Zhimeng [1 ,2 ,3 ]
Muraro, Andrea [4 ]
Gorini, Giuseppe [2 ,3 ,4 ]
McCormack, Oisin [2 ]
Cippo, Enrico Perelli [4 ]
Tardocchi, Marco [4 ]
Sun, Zhijia [5 ,6 ]
Zhou, Xiaojuan [5 ,6 ]
Zhou, Jianrong [5 ,6 ]
Xie, Yuguang [6 ]
Chen, Yuanbo [5 ,6 ]
Zhang, Hui [8 ,9 ]
Fan, Tieshuan [7 ]
Croci, Gabriele [2 ,3 ,4 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Dept Nucl Sci & Technol, Nanjing 211106, Peoples R China
[2] Univ Milano Bicocca, Dipartimento Fis, I-20126 Milan, Italy
[3] Ist Nazl Fis Nucl, Sez Milano Bicocca, I-20126 Milan, Italy
[4] CNR, Inst Plasma Sci & Technol, I-20125 Milan, Italy
[5] Spallat Neutron Source Sci Ctr, Dongguan 523803, Peoples R China
[6] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[7] Natl Inst Metrol, Beijing 100029, Peoples R China
[8] Peking Univ, Sch Phys, Beijing 100871, Peoples R China
[9] Peking Univ, State Key Lab Nucl Phys & Technol, Beijing 100871, Peoples R China
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2022年 / 1034卷
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Ceramic gas electron multiplier; Effective gain; Resolution; PHOTON DETECTORS; GEM; AMPLIFICATION;
D O I
10.1016/j.nima.2022.166824
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report the performance of a THick Gas Electron Multiplier (THGEM) fabricated by drilling holes in a gold-clad ceramic substrate using the standard PCB (Printed Circuit Board) technology and etching rims. The THGEM has a total thickness of 200 mu m with a hole diameter and rim size of 200 mu m and 80 mu m, respectively. In order to carry out a performance study, a detector was assembled by putting the THGEM inside a versatile chamber and irradiating it with a Fe-55 X-ray source (5.9 keV). An Ar/CO2 gas mixture was flushed inside the chamber at a pressure of about 1 atm, with volume ratios varying between 70/30 and 90/10. Pulse height spectra of the detector were recorded by a multichannel analyzer to investigate the gain and energy resolution at different drift and induction electric fields. The variations in the gain and energy resolution were also interpreted using simulations. The gain and resolution data of the THGEM were compared with those of a standard GEM which was measured using the same experimental setup.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Development of a thick gas electron multiplier for microdosimetry
    Orchard, G. M.
    Chin, K.
    Prestwich, W. V.
    Waker, A. J.
    Byun, S. H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 638 (01): : 122 - 126
  • [2] Interpretation of effective gain variations with the drift electric field for a ceramic thick gas electron multiplier
    Hu, Zhimeng
    Muraro, Andrea
    Croci, Gabriele
    McCormack, Oisin
    Cippo, Enrico Perelli
    Tardocchi, Marco
    Zhou, Xiaojuan
    Sun, Zhijia
    Zhou, Jianrong
    Xie, Yuguang
    Chen, Yuanbo
    Fan, Tieshuan
    Gorini, Giuseppe
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 988
  • [3] Study on gain stability of Thick Gas Electron Multiplier
    Li, Zhiyuan
    Ai, Xianyun
    Xie, Yuguang
    Hao, Liliang
    Wang, Ying
    Cui, Hui
    Fu, Li
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 986
  • [4] Study on gain stability of Thick Gas Electron Multiplier
    Li, Zhiyuan
    Ai, Xianyun
    Xie, Yuguang
    Hao, Liliang
    Wang, Ying
    Cui, Hui
    Fu, Li
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2021, 986
  • [5] Design and function of an electron mobility spectrometer with a thick gas electron multiplier
    Orchard, Gloria M.
    Puddu, Silvia
    Waker, Anthony J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 815 : 62 - 67
  • [6] A new approach to measure radon by Thick Gas Electron Multiplier
    Arsia, Rahim
    Salem, Mohammad Kazem
    Negarestani, Ali
    Sari, Amir Hossein
    RADIATION PHYSICS AND CHEMISTRY, 2022, 196
  • [7] A Thick Gas Electronic Multiplier
    Razin, V. I.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2020, 63 (02) : 161 - 164
  • [8] A Thick Gas Electronic Multiplier
    V. I. Razin
    Instruments and Experimental Techniques, 2020, 63 : 161 - 164
  • [9] The Thick Gas Electron Multiplier and its derivatives: Physics, technologies and applications
    Bressler, Shikma
    Moleri, Luca
    Jash, Abhik
    Tesi, Andrea
    Zavazieva, Darina
    PROGRESS IN PARTICLE AND NUCLEAR PHYSICS, 2023, 130
  • [10] Gain Characteristics of a 100 μm thick Gas Electron Multiplier (GEM)
    Mir, J. A.
    Natal da Luz, H.
    Carvalho, X.
    Azevedo, C. D. R.
    dos Santos, J. M. F.
    Amaro, F. D.
    JOURNAL OF INSTRUMENTATION, 2015, 10