In Vivo Cytometry of Antigen-Specific T Cells Using 19F MRI

被引:125
|
作者
Srinivas, Mangala [2 ]
Turner, Michael S. [3 ]
Janjic, Jelena M. [1 ]
Morel, Penelope A. [3 ]
Laidlaw, David H. [4 ]
Ahrens, Eric T. [1 ,5 ]
机构
[1] Carnegie Mellon Univ, Dept Biol Sci, Pittsburgh, PA 15213 USA
[2] Radboud Univ Nijmegen, Med Ctr, Nijmegen Ctr Mol Life Sci, Dept Tumor Immunol, NL-6525 ED Nijmegen, Netherlands
[3] Univ Pittsburgh, Sch Med, Dept Immunol, Pittsburgh, PA USA
[4] Brown Univ, Dept Comp Sci, Providence, RI 02912 USA
[5] Carnegie Mellon Univ, Pittsburgh NMR Ctr Biomed Res, Pittsburgh, PA 15213 USA
基金
美国国家卫生研究院;
关键词
in vivo cytometry; F-19; MRI; adaptive immunity; antigen-specific T cells; perfluoropolyether; ADOPTIVE IMMUNOTHERAPY; PHASE-I; PROLIFERATION; TRACKING; CANCER;
D O I
10.1002/mrm.22063
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Noninvasive methods to image the trafficking of phenotypically defined immune cells are paramount as we attempt to understand adaptive immunity. A F-19 MRI-based methodology for tracking and quantifying cells of a defined phenotype is presented. These methods were applied to a murine inflammation model using antigen-specific T cells. The T cells that were intracellularly labeled ex vivo with a perfluoropolyether (PFPE) nanoemulsion and cells were transferred to a host receiving a localized inoculation of antigen. Longitudinal F-19 MRI over 21 days revealed a dynamic accumulation and clearance of T cells in the lymph node (LN) draining the antigen. The apparent T-cell numbers were calculated in the LN from the time-lapse F-19 MRI data. The effect of in vivo T-cell division on the F-19 MRI cell quantification accuracy was investigated using fluorescence assays. Overall, in vivo cytometry using PFPE labeling and F-19 MRI is broadly applicable to studies of whole-body cell biodistribution. Magn Reson Med 62:747-753, 2009. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:747 / 753
页数:7
相关论文
共 50 条
  • [1] Labeling cells for in vivo tracking using 19F MRI
    Srinivas, Mangala
    Boehm-Sturm, Philipp
    Figdor, Carl G.
    de Vries, I. Jolanda
    Hoehn, Mathias
    BIOMATERIALS, 2012, 33 (34) : 8830 - 8840
  • [2] Using 19F MRI for In Vivo Tracking of Therapeutic Cells
    Mailliard, Robie B.
    Helfer, Brooke M.
    Janjic, Jelena M.
    Kalinski, Pawel
    Ahrens, Eric T.
    JOURNAL OF IMMUNOTHERAPY, 2009, 32 (09) : 948 - 948
  • [3] Antigen-specific blockade of T cells in vivo using dimeric MHC peptide
    O'Herrin, SM
    Slansky, JE
    Tang, Q
    Markiewicz, MA
    Gajewski, TF
    Pardoll, DM
    Schneck, JP
    Bluestone, JA
    JOURNAL OF IMMUNOLOGY, 2001, 167 (05): : 2555 - 2560
  • [4] Antigen-specific cytometry
    Andreas Thiel
    Andreas Radbruch
    Arthritis Research & Therapy, 1
  • [5] Antigen-specific cytometry
    Thiel, Andreas
    Radbruch, Andreas
    ARTHRITIS RESEARCH, 1999, 1 (01) : 25 - 29
  • [6] In vivo 19F MRI for Cell Tracking
    Srinivas, Mangala
    Boehm-Sturm, Philipp
    Aswendt, Markus
    Pracht, Eberhard D.
    Figdor, Carl G.
    de Vries, I. Jolanda
    Hoehn, Mathias
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2013, (81):
  • [7] The fate of adoptively transferred antigen-specific T cells in vivo
    Li, Z
    EUROPEAN JOURNAL OF IMMUNOLOGY, 1996, 26 (09) : 2208 - 2214
  • [8] Immunotherapy by using rejuvenated antigen-specific T cells
    Nishimura, T.
    Ando, M.
    Nakauchi, H.
    EUROPEAN JOURNAL OF IMMUNOLOGY, 2016, 46 : 519 - 520
  • [9] A unique 19F MRI agent for the tracking of non phagocytic cells in vivo
    Moonshi, Shehzahdi S.
    Zhang, Cheng
    Peng, Hui
    Puttick, Simon
    Rose, Stephen
    Fisk, Nicholas M.
    Bhakoo, Kishore
    Stringer, Brett W.
    Qiao, Greg G.
    Gurr, Paul A.
    Whittaker, Andrew K.
    NANOSCALE, 2018, 10 (17) : 8226 - 8239
  • [10] 19F MRI for quantitative in vivo cell tracking
    Srinivas, Mangala
    Heerschap, Arend
    Ahrens, Eric T.
    Figdor, Carl G.
    de Vries, I. Jolanda M.
    TRENDS IN BIOTECHNOLOGY, 2010, 28 (07) : 363 - 370