Debittering casein hydrolysates with octadecyl-siloxane (C18) columns

被引:16
|
作者
Lin, SB [1 ]
Nelles, LP [1 ]
Cordle, CT [1 ]
Thomas, RL [1 ]
机构
[1] ABBOTT LABS, ROSS PROD DIV, COLUMBUS, OH 43215 USA
关键词
casein hydrolysate; debittering; bitter peptide; hydrophobic adsorption; immunological properties;
D O I
10.1111/j.1365-2621.1997.tb15431.x
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Three casein hydrolysates (degree of hydrolysis (DH) of 23, 47, and 65.5 (%)) were debittered using three different hydrophobic adsorption columns, C18, C8, and phenolic resin (PR). Higher DH hydrolysates resulted in higher total nitrogen yields through the debittering process. The C18 and PR columns had more effective debittering than the C8 column, which had the highest processing yield. The PR column had much lower processing yield than the C18 column. Q-value correlated with bitterness in the hydrolysates. Antigenicity of treated hydrolysates was reduced by the debittering process.
引用
收藏
页码:665 / 670
页数:6
相关论文
共 50 条
  • [1] Physical factors related to C18 adsorption columns for debittering protein hydrolysates
    Lin, SB
    Nelles, LP
    Cordle, CT
    Thomas, RL
    JOURNAL OF FOOD SCIENCE, 1997, 62 (05) : 946 - &
  • [2] USE OF OCTADECYL (C18) COLUMNS FOR THE ESTIMATION OF ESTROGENS IN THE URINE OF NON-PREGNANT WOMEN
    GEBHARDT, DOE
    SOEDERHUIZEN, W
    MOOLENAAR, AJ
    ANNALS OF CLINICAL BIOCHEMISTRY, 1985, 22 (SEP) : 541 - 543
  • [3] A comparison of performance of various analytical columns in pharmaceutical analysis:: conventional C18 and high throughput C18 Zorbax columns
    Nováková, L
    Solich, P
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1088 (1-2) : 24 - 31
  • [4] Evaluation of C18 monolithic columns for radiochemical purity measurement
    Schenk, David J.
    Welch, Christopher J.
    Antonucci, Vincent
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2016, 59 (10): : 391 - 397
  • [5] Onyx™ C18 monolith columns for faster HPLC separations
    Waite, S
    Kallury, K
    McGinley, M
    LC GC EUROPE, 2005, : 46 - 46
  • [6] Comparison of the Separation Characteristics of the Organic–Inorganic Hybrid Octadecyl Stationary Phases XTerra MS C18 and XBridge C18 and Shield RP18 in RPLC
    Waruna Kiridena
    Colin F. Poole
    Sanka N. Atapattu
    Jing Qian
    Wladyslaw W. Koziol
    Chromatographia, 2007, 66 : 453 - 460
  • [7] Comparison of performance of C18 monolithic rod columns and conventional C18 particle-packed columns in liquid chromatographic determination of Estrogel and Ketoprofen gel
    Nováková, L
    Matysová, L
    Solichová, D
    Koupparis, MA
    Solich, P
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2): : 191 - 197
  • [8] Comparison of the separation characteristics of the organic-inorganic hybrid octadecyl stationary phases XTerra MS C18 and XBridge C18 and shield RP18 in RPLC
    Kiridena, Waruna
    Poole, Colin F.
    Atapattu, Sanka N.
    Qian, Jing
    Koziol, Wladyslaw W.
    CHROMATOGRAPHIA, 2007, 66 (7-8) : 453 - 460
  • [9] C4 and c18 capillary columns for LC/MS applications
    不详
    JOURNAL OF SEPARATION SCIENCE, 2001, 24 (02): : 158 - 158
  • [10] C18 flash columns in rapid isolation of organic compounds.
    Ghassemi, S