Simulation of an imaging system for internal contamination of lungs using MPA-MURA coded-aperture collimator

被引:5
|
作者
Zhang, Ting [1 ]
Wang, Lei [1 ]
Ning, Jing [3 ]
Lu, Wei [1 ]
Wang, Xiao-Fei [1 ]
Zhang, Hai-Wei [1 ]
Tuo, Xian-Guo [2 ]
机构
[1] Chengdu Univ Technol, Chengdu 610059, Peoples R China
[2] Sichuan Univ Sci & Engn, Zigong 643000, Peoples R China
[3] Beijing Inst Radiat Med, Beijing 100850, Peoples R China
基金
中国国家自然科学基金;
关键词
Lung internal contamination; MPA-MURA; Monte Carlo; MLEM; Spatial resolution; Detection efficiency;
D O I
10.1007/s41365-021-00849-3
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The nuclides inhaled during nuclear accidents usually cause internal contamination of the lungs with low activity. Although a parallel-hole imaging system, which is widely used in medical gamma cameras, has a high resolution and good image quality, owing to its extremely low detection efficiency, it remains difficult to obtain images of inhaled lung contamination. In this study, the Monte Carlo method was used to study the internal lung contamination imaging using the MPA-MURA coded-aperture collimator. The imaging system consisted of an adult male lung model, with a mosaicked, pattern-centered, and anti-symmetric MURA coded-aperture collimator model and a CsI (Tl) detector model. The MLEM decoding algorithm was used to reconstruct the internal contamination image, and the complementary imaging method was used to reduce the number of artifacts. The full width at half maximum of the I-131 point source image reconstructed by the MPA-MURA coded-aperture imaging reached 2.51 mm, and the signal-to-noise ratio of the simplified respiratory tract source (I-131) image reconstructed through MPA-MURA coded-aperture imaging was 3.98 dB. Although the spatial resolution of MPA-MURA coded-aperture imaging is not as good as that of parallel-hole imaging, the detection efficiency of PMA-MURA coded-aperture imaging is two orders of magnitude higher than that of parallel-hole collimator imaging. Considering the low activity level of internal lung contamination caused by nuclear accidents, PMA-MURA coded-aperture imaging has significant potential for the development of lung contamination imaging.
引用
收藏
页数:12
相关论文
共 45 条
  • [1] Simulation of an imaging system for internal contamination of lungs using MPA-MURA coded-aperture collimator
    Ting Zhang
    Lei Wang
    Jing Ning
    Wei Lu
    Xiao-Fei Wang
    Hai-Wei Zhang
    Xian-Guo Tuo
    Nuclear Science and Techniques, 2021, 32 (02) : 60 - 71
  • [2] Simulation of an imaging system for internal contamination of lungs using MPA-MURA coded-aperture collimator
    Ting Zhang
    Lei Wang
    Jing Ning
    Wei Lu
    Xiao-Fei Wang
    Hai-Wei Zhang
    Xian-Guo Tuo
    Nuclear Science and Techniques, 2021, 32
  • [3] Effect of collimator thickness on the imaging performance of coded-aperture gamma camera
    Fan, Donghai
    Tan, Tingting
    Zha, Gangqiang
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2025, 96 (04):
  • [4] A HYBRID CODED-APERTURE PARALLEL-PLATE COLLIMATOR FOR MULTIVIEW CARDIAC IMAGING
    FLYNN, MJ
    NEUMANN, DR
    WAKE, RH
    WIENER, SN
    JOURNAL OF NUCLEAR MEDICINE, 1982, 23 (05) : P59 - P59
  • [5] CODED-APERTURE IMAGING USING IMPERFECT DETECTOR SYSTEMS
    BYARD, K
    RAMSDEN, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 342 (2-3): : 600 - 608
  • [6] OBJECT DEPENDENT SYSTEM-DESIGN IN CODED-APERTURE IMAGING
    PAXMAN, RG
    BARRETT, HH
    SMITH, WE
    ACTA POLYTECHNICA SCANDINAVICA-APPLIED PHYSICS SERIES, 1985, (149): : 285 - 285
  • [7] Gamma Imaging Using Hybrid Coded-Aperture and Compton Scatter Imaging
    Montz, B.
    Hayward, J.
    Ramsey, C.
    MEDICAL PHYSICS, 2022, 49 (06) : E209 - E209
  • [8] Simulation Research of Terahertz Coded-aperture Imaging Technology with High Resolution
    Cao, Kaicheng
    Luo, Chenggao
    Cheng, Yongqiang
    Deng, Bin
    Qin, Yuliang
    Wang, Hongqiang
    Chen, Shuo
    2016 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS), 2016, : 3414 - 3418
  • [9] CHARACTERIZATION OF TERAHERTZ ANTENNAS USING PHOTOINDUCED CODED-APERTURE IMAGING
    Shams, M. I. B.
    Jiang, Z.
    Qayyum, J.
    Rahman, S. M.
    Xing, H. G.
    Hesler, J. L.
    Fay, P.
    Liu, L.
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2015, 57 (05) : 1180 - 1184
  • [10] Research on a Monte Carlo Simulation Method of Neutron Coded-Aperture Imaging
    Zhang, Huayang
    Zhong, Bin
    Shen, Huayun
    Cheng, Li
    Li, Jinhong
    NUCLEAR SCIENCE AND ENGINEERING, 2022, 196 (10) : 1236 - 1246