The pendant drop method of surface tension measurement: Equation interpolating the shape factor tables for several selected planes

被引:44
|
作者
Juza, J
机构
[1] Inst. of Macromolecular Chemistry, Acad. Sci. CR
关键词
D O I
10.1023/A:1022808017830
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
For evaluation of the surface tension by the pendant drop method, the method of selected plane is often preferred to more precise and sophisticated treatments. The several selected planes method, which implies better verification of data, is used only seldom, which is likely due to low accessibility of data for other planes in a suitable form. This article presents equations which express the parameter 1/H with a maximum deviation of 10(-4), in terms of the shape parameter S-k for 5 planes with the distance from drop apex equal to 0.8-1.2 multiple of the equatorial diameter d(e). The aim of this paper is only to introduce this tool for easier use of the method; the analysis of advantages and disadvantages of using several planes was made prior by several authors.
引用
收藏
页码:351 / 357
页数:7
相关论文
共 50 条
  • [1] MEASUREMENT OF SURFACE TENSION BY PENDANT DROP TECHNIQUE
    STAUFFER, CE
    JOURNAL OF PHYSICAL CHEMISTRY, 1965, 69 (06): : 1933 - &
  • [2] Accurate surface tension measurement of glass melts by the pendant drop method
    Chang, Yao-Yuan
    Wu, Ming-Ya
    Hung, Yi-Lin
    Lin, Shi-Yow
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (05):
  • [3] OSCILLATING PENDANT DROP - A METHOD FOR THE MEASUREMENT OF DYNAMIC SURFACE AND INTERFACE TENSION
    BADRAN, AA
    MARSCHALL, E
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1986, 57 (02): : 259 - 263
  • [4] Surface tension measurement with a smartphone using a pendant drop
    Chen, H.
    Muros-Cobos, Jesus L.
    Holgado-Terriza, Juan A.
    Amirfazli, A.
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2017, 533 : 213 - 217
  • [5] Surface tension measurement of normal human blood samples by pendant drop method
    Yadav S.S.
    Sikarwar B.S.
    Ranjan P.
    Janardhanan R.
    Goyal A.
    Journal of Medical Engineering and Technology, 2020, 44 (05): : 227 - 236
  • [7] MEASURING SURFACE TENSION BY MEANS OF PENDANT DROP METHOD
    MITTAG, U
    LANGE, KW
    DAHL, W
    ARCHIV FUR DAS EISENHUTTENWESEN, 1971, 42 (06): : 385 - &
  • [8] Design and accuracy of pendant drop methods for surface tension measurement
    Saad, Sameh M. I.
    Policova, Zdenka
    Neumann, A. Wilhelm
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2011, 384 (1-3) : 442 - 452
  • [9] Measurement of surface and interfacial tension using pendant drop tensiometry
    Berry, Joseph D.
    Neeson, Michael J.
    Dagastine, Raymond R.
    Chan, Derek Y. C.
    Tabor, Rico F.
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2015, 454 : 226 - 237
  • [10] Influence of drop volume on surface tension evaluated using the pendant drop method
    Augusto Morita
    Danilo Carastan
    Nicole Demarquette