Evaluation of the biocompatibility of a nonceramic hydroxyapatite

被引:45
|
作者
Liu, CS [1 ]
Wang, WB [1 ]
Shen, W [1 ]
Chen, TY [1 ]
Hu, LM [1 ]
Chen, ZW [1 ]
机构
[1] SHANGHAI MED UNIV,ZHONGSHAN HOSP,SHANGHAI 200032,PEOPLES R CHINA
关键词
D O I
10.1016/S0099-2399(97)80307-X
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
In this study, the biocompatibility of calcium phosphate cement (CPC) was systematically investigated, which included systemic injection acute toxicity assay, cell culture cytotoxicity assay, gene mutation assay (Ames test), chromosome aberration assay (micronucleus test), DNA damage assay (unscheduled DNA synthesis test) and implant histological evaluation. The results showed that the CPC had no toxicity and all tests for mutagenicity and potential carcinogenicity of CPC extracts are negative. CPC was implanted into the femurs of rabbits under no-load condition and the histology of specimens revealed that the implant tightly joined with the surrounding bone, only a very slight histological inflammatory reaction occurred. Thus, CPC is a highly biocompatible material and seems to be safe for application in humans.
引用
收藏
页码:490 / 493
页数:4
相关论文
共 50 条
  • [1] Biocompatibility evaluation of hydroxyapatite coatings for prosthetic applications
    Esquivel-Gaon, M.
    Uribe-Ramirez, M.
    Solorio-Rodriguez, A.
    Escamilla-Rivera, V.
    Munoz-Saldana, J.
    De Vizcaya-Ruiz, A.
    TOXICOLOGY LETTERS, 2015, 238 (02) : S94 - S94
  • [2] Biocompatibility evaluation of lithium-hydroxyapatite composites
    Valério, P
    Oktar, FN
    Goller, G
    Ozyegin, S
    Shainberg, APM
    Goese, AM
    Leite, MF
    BIOCERAMICS 18, PTS 1 AND 2, 2006, 309-311 : 1121 - 1124
  • [3] Synthesis of hydroxyapatite contining manganese and its evaluation of biocompatibility
    Fujitani, Wataru
    Hamada, Yoshinosuke
    Kawaguchi, Naomasa
    Mori, Seiji
    Daito, Kiyoshi
    Uchinaka, Ayako
    Matsumoto, Takuya
    Kojima, Yoshihisa
    Daito, Michiharu
    Nakano, Takayoshi
    Matsuura, Nariaki
    Nano Biomedicine, 2010, 2 (01) : 37 - 46
  • [4] Biocompatibility evaluation of dentine, enamel and bone derived hydroxyapatite
    Valerio, P
    Oktar, FN
    Ozyegin, LS
    Goller, G
    Goes, AM
    Leite, MF
    BIOCERAMICS 16, 2004, 254-2 : 837 - 840
  • [5] Biocompatibility Evaluation of Nano Hydroxyapatite-Starch Biocomposites
    Meskinfam, M.
    Sadjadi, M. A. S.
    Jazdarreh, H.
    Zare, K.
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2011, 7 (03) : 455 - 459
  • [6] Effects of synthetic nonceramic hydroxyapatite on human on human cells.
    Khodeiry, S
    Stephan, E
    Kamer, A
    Jackson, W
    Intini, G
    Bush, P
    Marzec, N
    Dziak, R
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 220 - 220
  • [7] Evaluation of the biocompatibility of a hydroxyapatite-CaTiO3 coating in vivo
    Wu, Song
    Tu, Bing
    Lin, Jianghong
    Wang, Zili
    Wang, Xiaokang
    Shen, Minren
    Hu, Rong
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2015, 35 (04) : 296 - 303
  • [8] Cell culture approach to biocompatibility evaluation of unconventionally prepared hydroxyapatite
    Kundu, PK
    Waghode, TS
    Bahadur, D
    Datta, D
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (05) : 654 - 658
  • [9] Evaluation of the In Vivo Biocompatibility of Hydroxyapatite Granules Incorporated with Zinc Ions
    de Lima, Ingrid Russoni
    Alves, Gutemberg Gomes
    de Oliveira Fernandes, Gustavo Vicentis
    Dias, Eliane Pedra
    Soares, Gloria de Almeida
    Granjeiro, Jose Mauro
    MATERIALS RESEARCH-IBERO-AMERICAN JOURNAL OF MATERIALS, 2010, 13 (04): : 563 - 568
  • [10] Biocompatibility evaluation of three different titanium-hydroxyapatite composites
    Sampaio, BV
    Göller, G
    Oktar, FN
    Valério, P
    Goes, AM
    Leite, MF
    BIOCERAMICS 17, 2005, 284-286 : 639 - 642