Volume of myocardium perfused by coronary artery branches as estimated from 3D micro-CT images of rat hearts

被引:2
|
作者
Lund, PE [1 ]
Naessens, LC [1 ]
Seaman, CA [1 ]
Reyes, DA [1 ]
Ritman, EL [1 ]
机构
[1] Mayo Clin, Dept Physiol & Biophys, Rochester, MN 55905 USA
关键词
myocardial perfusion; coronary blood flow; computed tomography; image analysis; coronary artery geometry;
D O I
10.1117/12.383412
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Average myocardial perfusion is remarkably consistent throughout the heart wall under resting conditions and the velocity of blood flow is fairly reproducible from artery to artery. Based on these observations, and the fact that flow through an artery is the product of arterial. cross-sectional area and blood flow velocity, we would expect the volume of myocardium perfused to be proportional to the cross-sectional area of the coronary artery perfusing that volume of myocardium. This relationship has been confirmed by others in pigs, dogs and humans. To test the body size-dependence of this relationship we used the hearts from rats, 3 through 25 weeks of age. The coronary arteries were infused with radiopaque microfil polymer and the hearts scanned in a micro-CT scanner. Using these 3D images we measured the volume of myocardium and the arterial cross-sectional area of the artery that perfused that volume of myocardium. The average constant of proportionality was found to be 0.15 +/- 0.08 cm(3)/mm(2). Our data showed no statistically different estimates of the constant of proportionality in the rat hearts of different ages nor between the left and right coronary arteries. This constant is smaller than that observed in large animals and humans, but this difference is consistent with the body mass-dependence on metabolic rate.
引用
收藏
页码:314 / 319
页数:4
相关论文
共 50 条
  • [1] Automatic segmentation of 3D micro-CT coronary vascular images
    Lee, Jack
    Beighley, Patricia
    Ritman, Erik
    Smith, Nicolas
    [J]. MEDICAL IMAGE ANALYSIS, 2007, 11 (06) : 630 - 647
  • [2] Micro-CT Guided 3D Reconstruction of Histological Images
    Nagara, Kai
    Roth, Holger R.
    Nakamura, Shota
    Oda, Hirohisa
    Moriya, Takayasu
    Oda, Masahiro
    Mori, Kensaku
    [J]. PATCH-BASED TECHNIQUES IN MEDICAL IMAGING (PATCH-MI 2017), 2017, 10530 : 93 - 101
  • [3] EFFICIENT EXTRACTION OF 3D BONE CELLS DESCRIPTORS FROM MICRO-CT IMAGES
    Dong, Pei
    Haupert, Sylvain
    Gouttenoire, Pierre-Jean
    Peyrin, Francoise
    [J]. 2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 1492 - 1495
  • [4] MYOCARDIAL VOLUME PERFUSED BY CORONARY-ARTERY BRANCHES - A POSTMORTEM AND 3-D X-RAY CT ANALYSIS
    LIU, YH
    BAHN, RC
    RITMAN, EL
    [J]. CLINICAL RESEARCH, 1990, 38 (03): : A809 - A809
  • [5] QUANTIFICATION OF THE 3D MORPHOLOGY OF THE BONE CELL NETWORK FROM SYNCHROTRON MICRO-CT IMAGES
    Dong, Pei
    Pacureanu, Alexandra
    Zuluaga, Maria A.
    Olivier, Cecile
    Grimal, Quentin
    Peyrin, Francoise
    [J]. IMAGE ANALYSIS & STEREOLOGY, 2014, 33 (02): : 157 - 166
  • [6] Strain measurement from 3D micro-CT images of a breast-mimicking phantom
    Lee, Soo Yeol
    Kim, Gyu Won
    Han, Byung Hee
    Cho, Min Hyoung
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2011, 41 (03) : 123 - 130
  • [7] 3D micro-CT images of ossicles destroyed by middle ear cholesteatoma
    Park, K
    Moon, SK
    Cho, MJ
    Won, YY
    Baek, MG
    [J]. ACTA OTO-LARYNGOLOGICA, 2004, 124 (04) : 403 - 407
  • [8] FEA Based on 3D Micro-CT Images of Mesoporous Engineered Hydrogels
    Siad, L.
    Jing, J.
    Braux, J.
    Dubus, M.
    Velard, F.
    Laurent-Maquin, D.
    Gangloff, S. C.
    Kerdjoudj, H.
    Rahouadj, R.
    Schmidt, J. -F.
    Ganghoffer, J. -F.
    [J]. ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2015, 5 (06) : 885 - 890
  • [9] Extraction and analysis of large vascular networks in 3D micro-CT images
    Wan, SY
    Ritman, EL
    Higgins, WE
    [J]. MEDICAL IMAGING 1999: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 1999, 3660 : 322 - 334
  • [10] 3D micro-CT for functional genomics
    Johnson, RH
    Molthen, RM
    Hanger, CC
    Karau, KL
    Haworth, ST
    Dawson, CA
    [J]. RADIOLOGY, 1999, 213P : 194 - 194