Challenges of implementing Point-of-Care Testing (POCT) glucose meters in a pediatric acute care setting

被引:20
|
作者
Kavsak, PA
Zielinski, N
Li, DL
McNamara, PJ
Adeli, K
机构
[1] Univ Toronto, Hosp Sick Children, Div Clin Biochem, Toronto, ON M5G 1X8, Canada
[2] Univ Toronto, Hosp Sick Children, Div Neonatol, Toronto, ON M5G 1X8, Canada
关键词
glucose measurements; NICU; glucose meters; Point-of-Care Testing; POCT;
D O I
10.1016/j.clinbiochem.2004.06.003
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: To investigate factors contributing to analytical bias in POCT glucose values generated by the NICU versus the core laboratory. Methods: The LifeScan Flexx hospital system glucose meters (SureStep) were used in precision and comparison studies between the NICU and laboratory (ABL715 and Vitros 950). Results: Analysis of 40 neonatal blood samples revealed a positive bias between the NICU glucose meters versus either the laboratory glucose meter or instrument (mean difference of 0.28 and 0.21 mmol/L, respectively). Linear regression analysis (R-2 = 0.0584) of the difference in glucose results versus time elapsed between measurements indicated that the bias observed between the NICU and laboratory glucose meters was not due to in vitro glycolysis for samples transported on ice. Further analysis indicated that the bias appeared to be mostly operator driven, with different NICU operators exhibiting different mean biases. Increasing the amount of blood applied to the SureStep Pro test strip (e.g., 60 vs. 20 muL), led to higher values for glucose concentration for the same blood. Nearly 50% of all glucose values reported for the NICU were obtained by the SureStep Flexx glucose meters in a 3-month period following the introduction of POCT, yet the number of laboratory-reported glucose results for the same period increased by 21% as compared to the previous year. Conclusions: Operator error appears to be a source of bias present between the NICU and laboratory, and despite glucose meter utilization in the NICU, the number of glucose measurements by the central laboratory increased after POCT introduction. (C) 2004 The Canadian Society of Clinical Chemists. All rights reserved.
引用
收藏
页码:811 / 817
页数:7
相关论文
共 50 条
  • [1] Managing the evaluation of a whole lot of connected point-of-care (POCT) glucose meters
    Blairon, L.
    Wilmet, A.
    Beukinga, I.
    CLINICA CHIMICA ACTA, 2019, 493 : S775 - S775
  • [2] Point-of-care testing (POCT) for haematology
    Briggs, Carol
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2008, 30 : 46 - 47
  • [3] Using Glucose Meters in Hospital Environments Some Challenges and Resolutions for Point-of-Care Testing
    Khan, Adil I.
    POINT OF CARE, 2014, 13 (03): : 97 - 100
  • [4] SKML-Quality Mark for point-of-care test (POCT) glucose meters and glucose meters for home-use
    Jansen, Rob T. P.
    Slingerland, Robbert J.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (07) : 1021 - 1027
  • [5] Inflammation markers in point-of-care testing (POCT)
    Albrecht Pfäfflin
    Erwin Schleicher
    Analytical and Bioanalytical Chemistry, 2009, 393
  • [6] Inflammation markers in point-of-care testing (POCT)
    Pfaefflin, Albrecht
    Schleicher, Erwin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (05) : 1473 - 1480
  • [7] Point-of-care testing (POCT) and IT security concepts
    Johannis, Wibke
    Bietenbeck, Andreas
    Malchau, Gebhart
    Streichert, Thomas
    JOURNAL OF LABORATORY MEDICINE, 2020, 44 (02) : 107 - 111
  • [8] Implementation of point-of-care testing in a pediatric healthcare setting
    Patel, Khushbu
    Suh-Lailam, Brenda B.
    CRITICAL REVIEWS IN CLINICAL LABORATORY SCIENCES, 2019, 56 (04) : 239 - 246
  • [9] Use of point-of-care glucose meters in the intensive care units
    Roman, A.
    Preiser, J. -C.
    REANIMATION, 2011, 20 (04): : 350 - 353
  • [10] Recommendations for the implementation and management of point-of-care testing (POCT)
    Di Serio, Francesca
    Trenti, Tommaso
    Carraro, Paolo
    BIOCHIMICA CLINICA, 2011, 35 (03) : 242 - 252