Comparison of SIRS, qSOFA, and NEWS for the early identification of sepsis in the Emergency Department

被引:170
|
作者
Usman, Omar A. [1 ,2 ]
Usman, Asad A. [3 ]
Ward, Michael A. [4 ]
机构
[1] Stanford Univ, Ctr Hlth Policy Primary Care & Outcomes Res, 117 Encino Commons, Stanford, CA 94305 USA
[2] VA Palo Alto Hlth Care Syst, Ctr Innovat Implementat Ci2i, 795 Willow Rd,152 MPD, Menlo Pk, CA 94025 USA
[3] Univ Penn, Dept Anesthesiol & Crit Care, 3400 Spruce St, Philadelphia, PA 19104 USA
[4] Univ Wisconsin, Dept Emergency Med, 800 Univ Dr Suite 310, Madison, WI 53705 USA
来源
关键词
Sepsis; Triage; Critical care; qSOFA; SIRS; NEWS; INFLAMMATORY RESPONSE SYNDROME; EARLY WARNING SCORE; INTERNATIONAL CONSENSUS DEFINITIONS; IN-HOSPITAL MORTALITY; ORGAN FAILURE; SEPTIC SHOCK; CLINICAL-CRITERIA; EARLY RECOGNITION; INFECTED PATIENTS; MEDS SCORE;
D O I
10.1016/j.ajem.2018.10.058
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives.: The increasing use of sepsis screening in the Emergency Department (ED) and the Sepsis-3 recommendation to use the quick Sepsis-related Organ Failure Assessment (LOOFA) necessitates validation. We compared Systemic Inflammatory Response Syndrome (SIRS), LISOFA, and the National Early Warning Score (NEWS) for the identification of severe sepsis and septic shock (SS/SS) during ED triage. Methods.: This was a retrospective analysis from an urban, tertiary-care academic center that included 130,595 adult visits to the ED, excluding dispositions lacking adequate clinical evaluation (n 14,861, 11.4%). The SS/ SS group (n 930) was selected using discharge diagnoses and chart review. We measured sensitivity, specificity, and area under the receiver-operating characteristic (AUROC) for the detection of sepsis endpoints. Results: NEWS was most accurate for triage detection of SS/SS (AUROC 0.91,0.88,0.81), septic shock (AUROC = 0.93, 0.88, 0.84), and sepsis-related mortality (AUROC = 0.95, 0.89, 0.87) for NEWS, SIRS, and qSOFA, respectively (p < 0.01 for NEWS versus SIRS and q50FA). For the detection of SS/SS (95% CI), sensitivities were 84.2% (81.5-86.5%), 86.1% (83.6-88.2%), and 28.5% (25.6-31.7%) and specificities were 85.0% (84.8-85.3%), 79.1% (78.9-79.3%), and 98.9% (98.8-99.0%) for NEWS >= 4, SIRS >= 2, and qSOFA >= 2, respectively. Conclusions: NEWS was the most accurate scoring system for the detection of all sepsis endpoints. Furthermore, NEWS was more specific with similar sensitivity relative to SIRS, improves with disease severity, and is immediately available as it does not require laboratories. However, scoring NEWS is more involved and may be better suited for automated computation. QSOFA had the lowest sensitivity and is a poor tool for ED sepsis screening. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:1490 / 1497
页数:8
相关论文
共 50 条
  • [1] Comparison of qSOFA, SIRS, and NEWS scoring systems for diagnosis, mortality, and morbidity of sepsis in emergency department
    Oduncu, Ali Fuat
    Kiyan, Guclu Selahattin
    Yalcinli, Sercan
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2021, 48 : 54 - 59
  • [2] Comparison the accuracy of early warning scores with qSOFA and SIRS for predicting sepsis in the emergency department
    Wattanasit, Prangsai
    Khwannimit, Bodin
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2021, 46 : 284 - 288
  • [3] Comparison of QSOFA score and SIRS criteria as screening mechanisms for emergency department sepsis
    Haydar, Samir
    Spanier, Matthew
    Weems, Patricia
    Wood, Samantha
    Strout, Tania
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2017, 35 (11): : 1730 - 1733
  • [4] SIRS, qSOFA, and organ failure for assessing sepsis at the emergency department
    Andaluz, David
    Ferrer, Ricard
    [J]. JOURNAL OF THORACIC DISEASE, 2017, 9 (06) : 1459 - 1462
  • [5] Classifying sepsis patients in the emergency department using SIRS, qSOFA or MEWS
    van der Woude, S. W.
    van Doormaal, F. F.
    Hutten, B. A.
    Nellen, F. J.
    Holleman, F.
    [J]. NETHERLANDS JOURNAL OF MEDICINE, 2018, 76 (04): : 158 - 166
  • [6] Monocyte Distribution Width Enhances Early Sepsis Detection in the Emergency Department Beyond SIRS and QSOFA
    Crouser, E. D.
    Parrillo, J.
    Martin, G. S.
    Huang, D. T.
    Hausfater, P.
    Grigorov, I.
    Careaga, D.
    Osborn, T.
    Hasan, M.
    Tejidor, L.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201
  • [7] Monocyte distribution width enhances early sepsis detection in the emergency department beyond SIRS and qSOFA
    Crouser, Elliott D.
    Parrillo, Joseph E.
    Martin, Greg S.
    Huang, David T.
    Hausfater, Pierre
    Grigorov, Ilya
    Careaga, Diana
    Osborn, Tiffany
    Hasan, Mohamad
    Tejidor, Liliana
    [J]. JOURNAL OF INTENSIVE CARE, 2020, 8 (01)
  • [8] Monocyte distribution width enhances early sepsis detection in the emergency department beyond SIRS and qSOFA
    Elliott D. Crouser
    Joseph E. Parrillo
    Greg S. Martin
    David T. Huang
    Pierre Hausfater
    Ilya Grigorov
    Diana Careaga
    Tiffany Osborn
    Mohamad Hasan
    Liliana Tejidor
    [J]. Journal of Intensive Care, 8
  • [9] Comparison Of Sirs And Qsofa Criteria In Screening For Patients With Severe Sepsis Or Septic Shock In The Emergency Department
    Nolan, M.
    Wardi, G.
    Sell, R.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [10] Predictive performance of NEWS and qSOFA in immunocompromised sepsis patients at the emergency department
    Boekhoud, Lisanne
    Schaap, Helena M. E. A.
    Huizinga, Rick L.
    Olgers, Tycho J.
    ter Maaten, Jan C.
    Postma, Douwe F.
    Bouma, Hjalmar R.
    [J]. INFECTION, 2024,