Evaluation of trickle bed air biofilter performance for BTEX removal

被引:84
|
作者
Sorial, GA [1 ]
Smith, FL [1 ]
Suidan, MT [1 ]
Pandit, A [1 ]
Biswas, P [1 ]
Brenner, RC [1 ]
机构
[1] US EPA,NAT RISK MGMT RES LAB,CINCINNATI,OH 45268
来源
关键词
D O I
10.1061/(ASCE)0733-9372(1997)123:6(530)
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Biofiltration of a gaseous stream contaminated with benzene, toluene, ethylbenzene, and the three xylene (BTEX) compounds was evaluated in this study. Experimental investigations were conducted on a pilot-scale biofilter containing randomly packed 6-mm R-635 Celite pellets as biological attachment media. The main focus of the study was to expand biofiltration technology to treat high volatile organic compounds (VOC) concentrations while maintaining consistently high removal efficiencies. Operational parameters investigated were BTEX loading, empty bed residence time (EBRT), backwashing frequency and duration, recovery of biofilter removal efficiency after backwashing, development of removal rate constants, and nutrient-phosphorous (nutrient-P) limitation as a biomass control. Periodic backwashing of the biofilter with medium fluidization was necessary for removing excess biomass and attaining stable long-term high removal efficiencies. Removal efficiencies above 99% were achieved for all the BTEX components for loadings up to 1.8 kg chemical oxygen demand (COD)/m(3)/d. Stable overall removal efficiencies of 88% were achieved for a BTEX loading of 6.2 kg COD/m(3)/d and an EBRT of 0.67 min. Evaluations of pseudo-steady-state performance data, one day following backwashing, yielded first-order removal rate constants for all the BTEX components. Removal efficiencies above 99% at BTEX loading of 2.1 kg COD/m(3)/d were attained for a period of 14 d without biofilter backwashing in the absence of nutrient-P.
引用
收藏
页码:530 / 537
页数:8
相关论文
共 50 条
  • [1] Evaluation of trickle-bed air biofilter performance for styrene removal
    Sorial, GA
    Smith, FL
    Suidan, MT
    Pandit, A
    Biswas, P
    Brenner, RC
    WATER RESEARCH, 1998, 32 (05) : 1593 - 1603
  • [2] Evaluation of trickle-bed air biofilter performance for MEK removal
    Cai, ZL
    Kim, D
    Sorial, GA
    JOURNAL OF HAZARDOUS MATERIALS, 2004, 114 (1-3) : 153 - 158
  • [3] Effects of pH, moisture, and flow pattern on trickle-bed air biofilter performance for BTEX removal
    Lu, CS
    Lin, MR
    Chu, CH
    ADVANCES IN ENVIRONMENTAL RESEARCH, 2002, 6 (02): : 99 - 106
  • [4] Performance evaluation of trickle-bed air biofilter packed with zeolite for ammonia removal
    Zhang, Jiao
    Xu, Xiaojun
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 4081 - +
  • [5] Removal of BTEX vapor from waste gases by a trickle bed biofilter
    Lu, Chungsying
    Chu, Wenchang
    Lin, Min-Ray
    Journal of the Air and Waste Management Association, 2000, 50 (03): : 411 - 417
  • [6] Removal of BTEX vapor from waste gases by a trickle bed biofilter
    Lu, CY
    Chu, WC
    Lin, MR
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2000, 50 (03): : 411 - 417
  • [7] Evaluation of trickle bed biofilter media for toluene removal
    Sorial, George A.
    Smith, Francis L.
    Suidan, Makram T.
    Biswas, Pratim
    Brenner, Richard C.
    1600, Air & Waste Management Assoc, Pittsburgh, PA, USA (45):
  • [8] EVALUATION OF TRICKLE-BED BIOFILTER MEDIA FOR TOLUENE REMOVAL
    SORIAL, GA
    SMITH, FL
    SUIDAN, MT
    BISWAS, P
    BRENNER, RC
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1995, 45 (10): : 801 - 810
  • [9] Impact of interchanging VOCs on the performance of trickle bed air biofilter
    Kim, D
    Cai, ZL
    Sorial, GA
    CHEMICAL ENGINEERING JOURNAL, 2005, 113 (2-3) : 153 - 160
  • [10] Temperature effects of trickle-bed biofilter for treating BTEX vapors
    Lu, CS
    Lin, MR
    Chu, CH
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1999, 125 (08): : 775 - 779