Comparison of multidetector computed tomography and two-dimensional transthoracic echocardiography for left ventricular assessment in patients with heart failure

被引:46
|
作者
Butler, Javed [1 ]
Shapiro, Michael D.
Jassal, Davindar
Neilan, Tomas
Nichols, John
Ferencik, Maros
Brady, Thomas J.
Hoffmann, Udo
Cury, Ricardo C.
机构
[1] Harvard Univ, Sch Med, Dept Radiol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Div Cardiol, Massachusetts Gen Hosp, Boston, MA 02115 USA
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2007年 / 99卷 / 02期
关键词
D O I
10.1016/j.amjcard.2006.08.021
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Along with coronary evaluation, 64-slice multidetector computed tomography (MDCT) permits comprehensive assessment of left ventricular (LV) anatomy and function; however, how it compares with 2-dimensional transthoracic echocardiography (TTE) in patients with heart failure (HF) is not known. In this study, we compared 25 patients with ejection fractions of < 45% who underwent TTE and MDCT. The global ejection fraction by TTE versus MDCT was 36 +/- 8% versus 38 +/- 12% (r = 0.67, p = NS). The mean LV end-diastolic and end-systolic diameters by TTE and MDCT were 56 8 and 46 9 mm and 58 +/- 12 and 47 +/- 11 mm, respectively (r = 0.71 and 0.77, respectively, both p > 0.20). The mean lateral and septal wall thicknesses by TTE and MDCT were 10 +/- 1.4 and 11 +/- 1.5 m and 10 +/- 1.3 and 10 +/- 1.4 mm (r = 0.77 and 0.76, respectively, both p > 0.20). The mean LV end-diastolic and end-systolic volumes and stroke volume by TTE and MDCT were 123 +/- 45, 78 +/- 31, and 44 +/- 21 ml and 140 +/- 58, 92 +/- 43, and 48 +/- 24 ml, respectively (r = 0.62, 0.67, and 0.60, respectively, all p > 0.20). The regional wall motion assessment correlation was good between the 2 modalities (kappa = 0.61). The interobserver correlation between the 2 MDCT readers ranged from good (r = 0.72 for LV end-diastolic volume) to excellent (r = 0.84 for septal wall thickness). In conclusion, MDCT provides comparable results to TTE for LV structure and functional assessment among patients with HF. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:247 / 249
页数:3
相关论文
共 50 条
  • [1] Comparison of multidetector computed tomography and two-dimensional transthoracic echocardiography for left ventricular assessment in patients with heart failure (vol 99, pg 247, 2007)
    Butler, J.
    Neilan, Tomas G.
    Jassal, Davinder S.
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (11): : 1622 - 1622
  • [2] Assessment of the aortic valve annular geometry by real-time three-dimensional transthoracic echocardiography: Comparison with two-dimensional transthoracic echocardiography and multidetector computed tomography
    Oshita C.
    Murata K.
    Wada Y.
    Nao T.
    Uchida K.
    Okuda S.
    Susa T.
    Tanaka N.
    Matsuzaki M.
    Yano M.
    Journal of Echocardiography, 2014, 12 (1) : 24 - 30
  • [3] Comparison of the Accuracy of Multidetector Computed Tomography Versus Two-Dimensional Echocardiography to Measure Left Atrial Volume
    Avelar, Erick
    Durst, Ronen
    Rosito, Guido A.
    Thangaroopan, Molly
    Kumar, Simi
    Tournoux, Francois
    Chan, Raymond C.
    Hung, Judy
    Hoffmann, Udo
    Abbara, Suhny
    Brady, Thomas
    Cury, Ricardo C.
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (01): : 104 - 109
  • [4] Overestimation of Left Ventricular Mass and Misclassification of Ventricular Geometry in Heart Failure Patients by Two-Dimensional Echocardiography in Comparison with Three-Dimensional Echocardiography
    Abramov, Dmitry
    Helmke, Stephen
    Rumbarger, Lyna El-Khoury
    King, Donald L.
    Maurer, Mathew S.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2010, 27 (03): : 223 - 229
  • [5] Reply to "Comparison of Accuracy of Left Atrial Area and Volume by Two-Dimensional Transthoracic Echocardiography Versus Computed Tomography"
    Ballo, Piercarlo
    Nistri, Stefano
    Cameli, Matteo
    Zuppiroli, Alfredo
    Mondillo, Sergio
    AMERICAN JOURNAL OF CARDIOLOGY, 2019, 124 (03): : 461 - 463
  • [6] Assessment of left ventricular ejection fraction and regional wall motion with 64-slice multidetector CT: a comparison with two-dimensional transthoracic echocardiography
    Ko, S-M
    Kim, Y-J
    Park, J-H
    Choi, N-M
    BRITISH JOURNAL OF RADIOLOGY, 2010, 83 (985): : 28 - 34
  • [7] Evaluation of Left Ventricular Outflow Tract Eccentricity in Patients With Aortic Valve Sclerosis Using 64-multidetector Computed Tomography: Comparison With Two-Dimensional Echocardiography
    Utsunomiya, Hiroto
    Yamamoto, Hideya
    Kunita, Eiji
    Ohashi, Norihiko
    Kitagawa, Toshiro
    Oka, Toshiharu
    Yamazato, Ryo
    Okada, Takenori
    Shokawa, Tomoki
    Nakano, Yukiko
    Teragawa, Hiroki
    Tadehara, Futoshi
    Ishida, Takafumi
    Horiguchi, Jun
    Kihara, Yasuki
    CIRCULATION, 2009, 120 (18) : S354 - S354
  • [8] Assessment of left ventricular function: comparison of cardiac multidetector-row computed tomography with two-dimension standard echocardiography for assessment of left ventricular function
    Darpan Bansal
    Robin M. Singh
    Mrinalini Sarkar
    Ravi Sureddi
    Kelly C. Mcbreen
    Timothy Griffis
    Anjan Sinha
    Jawahar L. Mehta
    The International Journal of Cardiovascular Imaging, 2008, 24 : 317 - 325
  • [9] Assessment of left ventricular function: comparison of cardiac multidetector-row computed tomography with two-dimension standard echocardiography for assessment of left ventricular function
    Bansal, Darpan
    Singh, Robin M.
    Sarkar, Mrinalini
    Sureddi, Ravi
    Mcbreen, Kelly C.
    Griffis, Timothy
    Sinha, Anjan
    Mehta, Jawahar L.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2008, 24 (03): : 317 - 325
  • [10] Assessment of left ventricular outflow tract and aortic root: comparison of 2D and 3D transthoracic echocardiography with multidetector computed tomography
    Visby, Lasse
    Kristensen, Charlotte Burup
    Pedersen, Frederik Holm Grund
    Sigvardsen, Per Ejlstrup
    Kofoed, Klaus Fuglsang
    Hassager, Christian
    Mogelvang, Rasmus
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 (10) : 1156 - 1163