Standardization of 68Ge-68Ga using 4πβ(LS)-γ coincidence counting system for activity measurements

被引:8
|
作者
Kulkarni, D. B. [1 ]
Joseph, Leena [1 ]
Anuradha, R. [1 ]
Kulkarni, M. S. [1 ]
Tomar, B. S. [2 ]
机构
[1] Bhabha Atom Res Ctr, Radiat Safety Syst Div, Bombay 400085, Maharashtra, India
[2] Bhabha Atom Res Ctr, Radioanalyt Chem Div, Bombay 400085, Maharashtra, India
关键词
4 pi beta(LS)-gamma coincidence counting system; Ge-68-Ga-68; CIEMAT/NIST; Monte-Carlo method;
D O I
10.1016/j.apradiso.2017.01.045
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Ga-68 has great scope for use in future for positron emission tomography (PET) imaging due to its very fast blood clearance and fast target localization, even though at present F-18 is widely used. Ge-68 in equilibrium with Ga-68 (Ge-68-Ga-68) can also be used as a surrogate for F-18 calibration, as F-18 source standardization can be done at national metrology institute (NMI) but, these standards cannot be sent to nuclear medicine centers (NMCs) across India for calibration of isotope calibrators, due to the short half-life of F-18 (110 min). Providing Ge-68-Ga-68 standards to NMCs requires that first standardization must be carried out at NMI (BARC in India) to provide traceability to the measurements carried out at NMCs. In the present work, standardization of Ge-68-Ga-68 was carried out using 4 pi beta(LS)-gamma coincidence counting system and CIEMAT/NIST efficiency tracing technique. The decay scheme correction factors for two gamma windows were calculated by Monte Carlo technique using general purpose code FLUKA. The activity concentration values were normalized by the activity concentration obtained by 4 pi beta(LS)-gamma coincidence counting system using window-1. The final result reported to BIPM for 4 pi beta(LS)-gamma coincidence counting was calculated by taking arithmetic mean of activity concentrations obtained for two gamma windows. The normalized activity concentration obtained by 4 pi beta(LS)-gamma coincidence counting was 0.998 +/- 0.005 and that obtained using CIEMAT/NIST efficiency tracing was 1.002 +/- 0.007 which are in excellent agreement within uncertainty limits.
引用
收藏
页码:6 / 10
页数:5
相关论文
共 50 条
  • [1] 68(Ge + Ga) activity standardization by 4πβ(LS)-γ(NaI(Tl)) anticoincidence counting measurements
    da Silva, C. J.
    da Cruz, P. A. L.
    Iwahara, A.
    de Oliveira, E. M.
    Loureiro, J. dos S.
    Tauhata, L.
    da Silva, Ronaldo L.
    Poledna, R.
    Lopes, R. T.
    APPLIED RADIATION AND ISOTOPES, 2018, 134 : 307 - 311
  • [2] Activity measurement of 68Ge-68Ga by use of 4π(β+ +γ) integral counting method
    Yamada, T.
    Ishizu, H.
    Kawada, Y.
    Yunoki, A.
    Yano, S.
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 325 - 329
  • [3] Standardization of 68Ge/68Ga using the 4πβ - γ coincidence method based on Cherenkov counting
    Bobin, C.
    Thiam, C.
    Bouchard, J.
    APPLIED RADIATION AND ISOTOPES, 2018, 134 : 252 - 256
  • [4] Standardization of Ga-68 by coincidence measurements, liquid scintillation counting and 4πγ counting
    Roteta, Miguel
    Peyres, Virginia
    Rodriguez Barquero, Leonor
    Garcia-Torano, Eduardo
    Arenillas, Pablo
    Balpardo, Christian
    Rodrigues, Dario
    Llovera, Roberto
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (09) : 2006 - 2011
  • [5] Activity determination of 68Ge/68Ga by means of 4πβ(sic)-γ coincidence counting
    Marganiec-Galazka, Justyna
    Naehle, Ole J.
    Kossert, Karsten
    APPLIED RADIATION AND ISOTOPES, 2018, 134 : 240 - 244
  • [6] 68Ge-68Ga发生器的研制——68Ge-68Ga发生器的稳定性研究
    汤启明
    赵贵植
    龙卫忠
    李大康
    核化学与放射化学, 1997, (04) : 57 - 60
  • [7] Standardization of 68Ga by means of a 4πβ-γ Software Coincidence System
    Koskinas, M. F.
    Lacerda, F. W.
    Yamazaki, I. M.
    Toledo, F.
    Takeda, M. N.
    Dias, M. S.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 269 - 272
  • [8] Preparation and study of 68Ge-68Ga generator separation of 68Ge from Ga by adsorption on silica gel
    He-Huaxue yu Fangshe Huaxue/Journal of Nuclear and Radiochemistry, 1997, 19 (02): : 29 - 33
  • [9] Standardization of 68Ge/68Ga Using Three Liquid Scintillation Counting Based Methods
    Zimmerman, B. E.
    Cessna, J. T.
    Fitzgerald, R.
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2008, 113 (05): : 265 - 280
  • [10] Standardization of 68(Ge+Ga)
    Grigorescu, EL
    Negut, CD
    Luca, A
    Razdolescu, AC
    Tanase, M
    APPLIED RADIATION AND ISOTOPES, 2004, 60 (2-4) : 429 - 431