Transient stability study of the large synchronous motors starting and operating for the isolated integrated steel-making facility

被引:0
|
作者
Hsu, CT [1 ]
Cheng, HS [1 ]
机构
[1] So Taiwan Univ Technol, Dept Elect Engn, Tainan, Taiwan
关键词
cogeneration; motor starting; transient stability;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents the influences of the large motor starting and the large rolling mill operation on the isolated integrated steel cogeneration facility by executing the transient stability analysis. The system configuration of the steel facility will be introduced first. Furthermore, the proper mathematical models and the accurate parameters of the co-generators, excitation systems and governor systems are investigated in detail. Both the static and dynamic load models are applied in this paper. To reduce the starting current of large motors, the conventional step-down voltage method by adjusting the suitable tap position of the autotransformer and the constant magnetic flux control method by using the VVVF inverter are considered in the computer simulations. Also, the system voltage and frequency fluctuations due to the operation of the rolling mill will be observed and investigated carefully to verify the isolated cogeneration can be operated well and safely.
引用
收藏
页码:877 / 882
页数:6
相关论文
共 5 条
  • [1] Transient stability study of the large synchronous motors starting and operating for the isolated integrated steel-making facility
    Hsu, CT
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2003, 39 (05) : 1436 - 1441
  • [2] Power quality assessment of large motor starting and loading for the integrated steel-making cogeneration facility
    Hsu, CT
    Chuang, HJ
    CONFERENCE RECORD OF THE 2005 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2005, : 59 - 66
  • [3] Power quality assessment of large motor starting and loading for the integrated steel-making cogeneration facility
    Hsu, Cheng-Ting
    Chuang, Hui-Jen
    Chen, Chao-Shun
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2007, 43 (02) : 395 - 402
  • [4] A STATIC VAR SYSTEM FOR STARTING AND OPERATING LARGE SYNCHRONOUS COMPRESSOR MOTORS
    DYER, RT
    MCCUE, DR
    WILLIAMS, SL
    SWENCKI, SJ
    THOITS, PO
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1987, 23 (01) : 166 - 172
  • [5] Study on Transient Voltage Stability and Improvement Measures of Paralleled Virtual Synchronous Generators System With Induction Motors
    Cheng H.
    Shuai Z.
    Peng Y.
    Shen C.
    Zhao F.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2021, 41 (14): : 4787 - 4798