Hemoglobin immobilized in exfoliated Co2Al LDH-graphene nanocomposite film: Direct electrochemistry and electrocatalysis toward trichloroacetic acid

被引:62
|
作者
Zhan, Tianrong [1 ]
Wang, Xinjun [1 ]
Li, Xianjun [1 ]
Song, Yang [1 ]
Hou, Wanguo [2 ]
机构
[1] Qingdao Univ Sci & Technol, Minist Educ, Key Lab Sensor Anal Tumor Marker, State Key Lab Base Ecochem Engn, Qingdao 266042, Peoples R China
[2] Shandong Univ, Minist Educ, Key Lab Colloid & Interface Chem, Jinan 250100, Peoples R China
基金
中国国家自然科学基金;
关键词
Hemoglobin; Exfoliated layered double hydroxide; Graphene; Direct electrochemistry; Electrocatalysis; LAYERED DOUBLE HYDROXIDES; COMPOSITE-MODIFIED ELECTRODE; IONIC LIQUID ELECTRODE; NANOPARTICLES; FABRICATION; REDUCTION; NANORODS; CHITOSAN; HYBRID; OXIDE;
D O I
10.1016/j.snb.2015.12.095
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sandwich-like nanocomposite of exfoliated Co2Al layered double hydroxide (ELDH) and graphene (GR) was synthesized by chemically reducing in situ the assembly of ELDH and graphene oxide (GO) nanosheets. The morphology and structure of the product were characterized by scanning electron microscope (SEM), transmission electron microscope (TEM), X-ray diffraction (XRD) and atomic force microscopy (AFM). Then the ELDH-GR nanocomposite and chitosan (CTS) were employed for immobilization of hemoglobin (Hb) on a carbon ionic liquid electrode (CILE) to fabricate a trichloroacetic acid (TCA) biosensor. The UV-Vis, FTIR and fluorescence spectra showed that Hb kept its native structure and retained stable bioactivity in the composite material. Cyclic voltammetry (CV) displayed a pair of well-defined redox peaks with the formal peak potential (E-0') at 0.256V (vs. SCE), in pH 4.0 Britton-Robinson solution at the scan rate of 0.1 V/s, implying the direct electron transfer of Hb-Fe-III/Fe-II. The electron transfer coefficient (alpha) and the apparent heterogeneous electron transfer rate constant (k(s)) were calculated to be 0.492 and 1.202 s(-1), respectively. The Hb-modified electrode presented excellent electro-reduction activity toward TCA in the concentration range from 5 to 360 mmol/L with the detection limit of 1.506 mmol/L (36) by CV. For square wave voltammetry (SWV), the concentration range and the detection limit were from 2.5 to 360 mmol/L and 0.82 mmol/L, respectively. Therefore, the ELDH-GR composite has a promising potential for construction of biosensors. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:101 / 108
页数:8
相关论文
共 9 条
  • [1] Hemoglobin immobilized in g-C3N4 nanoparticle decorated 3D graphene-LDH network: Direct electrochemistry and electrocatalysis to trichloroacetic acid
    Zhan, Tianrong
    Tan, Zhengwei
    Wang, Xinjun
    Hou, Wanguo
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 149 - 158
  • [2] Direct Electrochemistry and Electrocatalysis of Hemoglobin Immobilized on the Functionalized Graphene-Carbon Nanotube Composite Film
    Wang, Minzhi
    Zheng, Jianbin
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2012, 159 (06) : F150 - F156
  • [3] Direct electrochemistry and electrocatalysis of horseradish peroxidase immobilized in graphene oxide-Nafion nanocomposite film
    Zhang, Lili
    Cheng, Huhu
    Zhang, Hui-Min
    Qu, Liangti
    ELECTROCHIMICA ACTA, 2012, 65 : 122 - 126
  • [4] Direct Electrochemistry and Electrocatalysis of Myoglobin Immobilized on Graphene-CTAB-Ionic Liquid Nanocomposite Film
    Liao, Hong-gang
    Wu, Hong
    Wang, Jun
    Liu, Jun
    Jiang, Yan-Xia
    Sun, Shi-Gang
    Lin, Yuehe
    ELECTROANALYSIS, 2010, 22 (19) : 2297 - 2302
  • [5] Direct electrochemistry and electrocatalysis of hemoglobin immobilized into poly (lactic-co-glycolic acid)/room temperature ionic liquid composite film
    Zhang, Yao
    Sun, Xiumei
    Jia, Nengqin
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 157 (02): : 527 - 532
  • [6] Direct electrochemistry and electrocatalysis of hemoglobin immobilized on an interlaced Co(OH)2 nanosheet-based three-dimensional macroporous film
    Xie, Qing
    Chen, Xu
    Liu, Haimei
    Yang, Wensheng
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 168 : 277 - 282
  • [7] Direct electrochemistry and electrocatalysis of hemoglobin on chitosan-room temperature ionic liquid-TiO2-graphene nanocomposite film modified electrode
    Sun, Jun-Yong
    Huang, Ke-Jing
    Zhao, Su-Fang
    Fan, Yang
    Wu, Zhi-Wei
    BIOELECTROCHEMISTRY, 2011, 82 (02) : 125 - 130
  • [8] Direct electrochemistry of glucose oxidase immobilized on TiO2-graphene/nickel oxide nanocomposite film and its application
    Xu, Chun-Xuan
    Huang, Ke-Jing
    Chen, Xue-Min
    Xiong, Xiao-Qin
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (12) : 3747 - 3752
  • [9] Direct electrochemistry of glucose oxidase immobilized on TiO2–graphene/nickel oxide nanocomposite film and its application
    Chun-Xuan Xu
    Ke-Jing Huang
    Xue-Min Chen
    Xiao-Qin Xiong
    Journal of Solid State Electrochemistry, 2012, 16 : 3747 - 3752