Measurement and stability of FTY720 in human whole blood by high-performance liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry

被引:14
|
作者
Salm, Paul
Warnholtz, Christopher R.
Lynch, Stephen V.
Taylor, Paul J.
机构
[1] Princess Alexandra Hosp, Dept Clin Pharmacol, Brisbane, Qld 4102, Australia
[2] Univ Queensland, Dept Med, Brisbane, Qld 4102, Australia
[3] Princess Alexandra Hosp, Dept Surg, Brisbane, Qld 4102, Australia
[4] Princess Alexandra Hosp, Australian Bioanalyt Serv Pty Ltd, Brisbane, Qld 4102, Australia
关键词
FTY720; HPLC; mass spectrometry; APCI; immunosuppressant drug;
D O I
10.1016/j.jchromb.2006.05.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report here a validated method for the quantification of a new immunosuppressant drug FTY720, using HPLC-tandem mass spectrometry. Whole blood samples (500 mu l) were subjected to liquid-liquid extraction, in the presence of an internal standard (Y-32919). Mass spectrometric detection was by selected reaction monitoring with an atmospheric pressure chemical ionization source in positive ionization mode (FTY720: m/z 308.3 -> 255.3). The assay was linear from 0.2 to 25 mu g/l (r(2) > 0.997, n = 5). The inter- and intra-day analytical recovery and imprecision for quality control samples (0.5, 7 and 15 mu g/l) were 95.8-103.2 and < 5.5%, respectively. At the lower limit of quantification (0.2 mu g/l) the interand intra-day analytical recovery was 99.0-102.8% with imprecision of < 7.6% (n = 5). The assay had a mean relative recovery of 100.5 +/- 5.8% (n = 15). Extracted samples were stable for 16 h. IFTY720 quality control samples were stable at room temperature for 16 h at 4 degrees C for at least 8 days and when taken through at least three freeze-thaw cycles. In conclusion, the method described displays analytical performance characteristics that are suitable for pharmacokinetic studies in humans. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:157 / 163
页数:7
相关论文
共 50 条
  • [1] Measurement of ethyl methanesulfonate in human plasma and breast milk samples using high-performance liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry
    Montesano, M. Angela
    Whitehead, Ralph D., Jr.
    Jayatilaka, Nayana K.
    Kuklenyik, Peter
    Davis, Mark D.
    Needham, Larry L.
    Barr, Dana Boyd
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 52 (02) : 260 - 264
  • [2] High-performance liquid chromatography-atmospheric pressure chemical ionization/tandem mass spectrometry for the determination of a thiol compound in plasma
    Wang, GF
    Hsieh, YS
    Wang, L
    Prelusky, D
    Korfmacher, WA
    Morrison, R
    ANALYTICA CHIMICA ACTA, 2003, 492 (1-2) : 215 - 221
  • [3] Quantitative determination of dexamethasone in bovine milk by liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry
    Cherlet, M
    De Baere, S
    De Backer, P
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (01): : 57 - 65
  • [4] A validated liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry method for quantitation of cocaine and benzoylecgonine in human plasma
    Lin, SN
    Moody, DE
    Bigelow, GE
    Foltz, RL
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2001, 25 (07) : 497 - 503
  • [5] Ultra-high performance liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry for the analysis of benzimidazole compounds in milk samples
    Martinez-Villalba, Anna
    Moyano, Encarnacion
    Teresa Galceran, Maria
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1313 : 119 - 131
  • [6] Chiral bioanalysis by normal phase high-performance liquid chromatography-atmospheric pressure ionization tandem mass spectrometry
    AlebicKolbah, T
    Zavitsanos, AP
    JOURNAL OF CHROMATOGRAPHY A, 1997, 759 (1-2) : 65 - 77
  • [7] Potential of gas chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry for screening and quantification of hexabromocyclododecane
    Sales, Carlos
    Portoles, Tania
    Vicente Sancho, Juan
    Abad, Esteban
    Abalos, Manuela
    Saulo, Jordi
    Fiedler, Heidelore
    Gomara, Belen
    Beltran, Joaquim
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (02) : 449 - 459
  • [8] Potential of gas chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry for screening and quantification of hexabromocyclododecane
    Carlos Sales
    Tania Portolés
    Juan Vicente Sancho
    Esteban Abad
    Manuela Ábalos
    Jordi Sauló
    Heidelore Fiedler
    Belén Gómara
    Joaquim Beltrán
    Analytical and Bioanalytical Chemistry, 2016, 408 : 449 - 459
  • [9] Enantioselective determination of cetirizine in human plasma by normal-phase liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry
    Kang, Seung Woo
    Jang, Hae Jong
    Moore, Victor S.
    Park, Ji-Young
    Kim, Kyoung-Ah
    Youm, Jeong-Rok
    Han, Sang Beom
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (32): : 3351 - 3357
  • [10] A highly specific and sensitive quantification analysis of the sterols in silkworm larvae by high performance liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry
    Igarashi, Fumihiko
    Hikiba, Juri
    Ogihara, Mari H.
    Nakaoka, Takayoshi
    Suzuki, Minoru
    Kataoka, Hiroshi
    ANALYTICAL BIOCHEMISTRY, 2011, 419 (02) : 123 - 132