Phantom-based evaluation of geometric distortions in functional magnetic resonance and diffusion tensor imaging

被引:16
|
作者
Mattila, Seppo
Renvall, Ville
Hiltunen, Jaana
Kirven, Douglas
Sepponen, Raimo
Hari, Riitta
Tarkiainen, Antti
机构
[1] Helsinki Univ Technol, TKK, AMI Ctr, FI-02015 Espoo, Finland
[2] Helsinki Univ Technol, TKK, Low Temp Lab, Brain Res Unit, FI-02015 Espoo, Finland
[3] Queens Univ Belfast, Sch Math & Phys, Astrophys Res Ctr, Belfast BT7 1NN, Antrim, North Ireland
[4] Univ Helsinki, Ctr Neurosci, FIN-00014 Helsinki, Finland
[5] Helsinki Univ Technol, TKK, Appl Elect Lab, FI-02015 Espoo, Finland
关键词
phantom design; artifacts; geometric distortion; functional MRI; diffusion-weighted image; diffusion tensor imaging;
D O I
10.1002/mrm.21218
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Phantom-based evaluation of geometric distortions in functional MRI and diffusion tensor imaging (DTI) was investigated. An acrylic water-filled phantom with a grid structure was designed and manufactured to provide accurate geometric information over the volume measured in human brain imaging. The grid structures were well detected in data acquired using a 3-T MRI scanner with echo-planar imaging (EPI) sequences commonly applied in functional MRI and DTI. A method for quantifying distortions in the phantom data was presented and applied for the images. The validity of the phantom for EPI was evaluated by quantitatively comparing the distortions present in and induced by the phantom and a human brain when imaged under identical conditions. The results suggest that the new phantom can reveal geometric distortions easily undermined by standard MRI phantoms. For example, prominent variability in the distortions was found as a function of the orientation of the diffusion-sensitizing gradient. Possible future applications for this type of phantom include quality assurance and calibration of the hardware and software used in EPI-based functional MRI and DTI.
引用
收藏
页码:754 / 763
页数:10
相关论文
共 50 条
  • [1] Microfluidic laminate-based phantom for diffusion tensor-magnetic resonance imaging
    Samuel, R.
    Sant, H. J.
    Jiao, F.
    Johnson, C. R.
    Gale, B. K.
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2011, 21 (09)
  • [2] Phantom-based characterization of distortion on a magnetic resonance imaging simulator for radiation oncology
    Huang, Ke
    Cao, Yue
    Baharom, Umar
    Balter, James M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (02): : 774 - 790
  • [3] Functional and diffusion tensor magnetic resonance imaging of the sheep brain
    Wonhye Lee
    Stephanie D. Lee
    Michael Y. Park
    Lori Foley
    Erin Purcell-Estabrook
    Hyungmin Kim
    Seung-Schik Yoo
    [J]. BMC Veterinary Research, 11
  • [4] Functional and diffusion tensor magnetic resonance imaging of the sheep brain
    Lee, Wonhye
    Lee, Stephanie D.
    Park, Michael Y.
    Foley, Lori
    Purcell-Estabrook, Erin
    Kim, Hyungmin
    Yoo, Seung-Schik
    [J]. BMC VETERINARY RESEARCH, 2015, 11
  • [5] Imaging of Brain Tumors: Functional Magnetic Resonance Imaging and Diffusion Tensor Imaging
    Gupta, Ajay
    Shah, Akash
    Young, Robert J.
    Holodny, Andrei I.
    [J]. NEUROIMAGING CLINICS OF NORTH AMERICA, 2010, 20 (03) : 379 - +
  • [6] Magnetic resonance diffusion tensor imaging for evaluation of diabetic polyneuropathy
    Vaeggemose, M.
    Pham, M.
    Ringgaard, S.
    Tankisi, H.
    Ejskjaer, N.
    Poulsen, P.
    Andersen, H.
    [J]. EUROPEAN JOURNAL OF NEUROLOGY, 2016, 23 : 83 - 83
  • [7] Diffusion tensor magnetic resonance imaging
    Gulani, V
    Sundgren, PC
    [J]. JOURNAL OF NEURO-OPHTHALMOLOGY, 2006, 26 (01) : 51 - 60
  • [8] Diffusion tensor magnetic resonance imaging
    Herrnberger, B
    [J]. NERVENHEILKUNDE, 2004, 23 (01) : 50 - 59
  • [9] Phantom-based performance evaluation: Application to brain segmentation from magnetic resonance images
    Moretti, B
    Fadili, JM
    Ruan, S
    Bloyet, D
    Mazoyer, B
    [J]. MEDICAL IMAGE ANALYSIS, 2000, 4 (04) : 303 - 316
  • [10] Reproducibility of geometric distortion in magnetic resonance imaging based on phantom studies
    Mizowaki, T
    Nagata, Y
    Okajima, K
    Kokubo, M
    Negoro, Y
    Araki, N
    Hiraoka, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 2000, 57 (02) : 237 - 242