Anterior spinal artery and artery of Adamkiewicz detected by using multi-detector row CT

被引:0
|
作者
Kudo, K [1 ]
Terae, S [1 ]
Asano, T [1 ]
Oka, M [1 ]
Kaneko, K [1 ]
Ushikoshi, S [1 ]
Miyasaka, K [1 ]
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Radiol, Kita Ku, Sapporo, Hokkaido 0608638, Japan
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Our purpose was to evaluate the visualization of the artery of Adamkiewicz (AKA) and the anterior spinal artery (ASA) by using multi-detector row CT. Preoperative detection of the AKA and ASA is important for prevention of ischemic complications of thoracoabdominal aortic surgery. METHODS: Data from contrast-enhanced CT of the abdomen of 19 consecutive patients with known or suspected liver disease were evaluated. The scanning range was set from the level of the diaphragm to the lower edge of the liver. After bolus injection of contrast material (100 mL of iohexol, 350 mgI/mL, 5 mL/s), arterial phase scans were obtained by using a four-channel multi-detector row CT scanner. The scanning parameters included a detector row configuration of 4 X 2 mm, a pitch of 5:1, a gantry rotation speed of 0.5 s, 120 kVp, and 150 mAs. Arterial phase coronal multiplanar reconstruction scans obtained parallel to the spinal cord were evaluated by two neuroradiologists. The detectability of ASA and AKA was analyzed. RESULTS: The AKA was visualized on the scans of 13 of 19 patients (68%). The segmental level of AKA origin ranged from T10 to L2. The AKA originated from the left side in nine patients (69%) and the right side in four patients (31%). The ASA was visualized on the scans of all patients (100%). For 16 of the 19 patients, the ASA was detected in its full length from the cranial edge of the scan range. However, the ascending branch of the ASA distal to the junction of the AKA was not detected for the remaining three patients. CONCLUSION. The AKA and ASA can be visualized by using multi-detector row CT with the use of IV administered contrast material. Multi-detector row CT could be a useful tool in the evaluation of spinal vascular structures.
引用
收藏
页码:13 / 17
页数:5
相关论文
共 50 条
  • [1] Assessment of the anterior spinal artery and the artery of Adamkiewicz using multi-detector CT angiography
    Zhao Shao-Hong
    Logan, Laura
    Schraedley, Pamela
    Rubin, Geoffrey D.
    [J]. CHINESE MEDICAL JOURNAL, 2009, 122 (02) : 145 - 149
  • [2] Assessment of the anterior spinal artery and the artery of Adamkiewicz using multi-detector CT angiography
    Laura Logan
    Pamela Schraedley
    Geoffrey D.Rubin
    [J]. 中华医学杂志(英文版), 2009, (02) : 145 - 149
  • [3] Demonstration of the artery of Adamkiewicz at multi-detector row helical CT
    Takase, K
    Sawamura, Y
    Igarashi, K
    Chiba, Y
    Haba, K
    Saito, H
    Takahashi, S
    [J]. RADIOLOGY, 2002, 223 (01) : 39 - 45
  • [4] Model-based Iterative Reconstruction for Multi-Detector Row CT Assessment of the Adamkiewicz Artery
    Nishida, Junko
    Kitagawa, Kakuya
    Nagata, Motonori
    Yamazaki, Akio
    Nagasawa, Naoki
    Sakuma, Hajime
    [J]. RADIOLOGY, 2014, 270 (01) : 282 - 291
  • [5] Multi-detector CT angiography for the assessment of anterior spinal artery and artery of Adamkiewicz patency in patients suspected of having thoracic aortic pathology
    Laura Logan
    Pamela Schraedley
    Geoffrey D.Rubin
    [J]. Journal of Geriatric Cardiology, 2006, (01) : 52 - 56
  • [6] Visualization of the Adamkiewicz Artery in Patients with Acute Stanford A Dissections: A Prospective 64-Row Multi-Detector CT Study
    Kovacs, A.
    Schiller, W.
    Gerhards, H. M.
    Welz, A.
    Willinek, W. A.
    Schild, H.
    Urbach, H.
    Flacke, S.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2009, 181 (09): : 870 - 874
  • [7] Imaging of anterior spinal artery and artery of Adamkiewicz using half-second multi-slice helical CT
    Kato, R
    Katada, K
    Anno, H
    Nakane, M
    Hayakawa, M
    Koga, S
    [J]. RADIOLOGY, 2000, 217 : 188 - 189
  • [8] The utility of multi-detector row spiral CT for detection of coronary artery stenoses
    Moon, JY
    Chung, N
    Choi, BW
    Choe, KO
    Seo, HS
    Ko, YG
    Kang, SM
    Ha, JW
    Rim, SJ
    Jang, YS
    Shim, WH
    Cho, SY
    [J]. YONSEI MEDICAL JOURNAL, 2005, 46 (01) : 86 - 94
  • [9] Evaluation of patency of coronary-artery bypass graft using multi-detector row CT
    Kim, M
    Choi, B
    Choi, DH
    Choe, KO
    Choi, H
    Kim, J
    [J]. RADIOLOGY, 2002, 225 : 390 - 390
  • [10] Pulmonary embolism: Optimization of small pulmonary artery visualization at multi-detector row CT
    Patel, S
    Kazerooni, EA
    Cascade, PN
    [J]. RADIOLOGY, 2003, 227 (02) : 455 - 460